Site Characteristics - CORRECT-ANSWERSexisting structures; slopes; wells;
streams influence system design

Soil Characteristics - CORRECT-ANSWERS40 million bacterial cells in a single
gram of soil Healthy soil is living and breathing and packed with microbes
that breakdown pathogens

Any sewage treatment method has two components: - CORRECT-ANSWERSa
pre-treatment option, such as a septic tank or sand filter, and a dispersal
system, such as a leach field or low-pressure distribution setup.

Pipe from the final treatment tank to a gravity disposal system - CORRECT-
ANSWERSshall be a minimum of 5' in length

Pipe that crosses drainage easements - CORRECT-ANSWERSshall be sleeved
with ASTM Schedule 40 pipe; the pipes shall be buried at least one foot
below the surface, or buried less than one foot and encased with concrete;
the outside pipe shall have locater tape attached to the pipe; and markers
shall be placed at the easement boundaries to indicate the location of the
pipe crossing. Crossings shall be designed and constructed in a manner that
protects the pipe and the drainage way from erosion.

Drainline - CORRECT-ANSWERSThe drainline shall be constructed of
perforated distribution pipe and fittings in compliance with any one of the
following specifications
1) three or four inch diameter PVC pipe with an SDR of 35 or stronger
2)four-inch diameter corrugated polyethylene, ASTM F405 in rigid ten foot
joints
3)three or four inch diameter polyethylene smoothwall, ASTM F810
4)three or four inch diameter PVC ASTM D2729 pipe
5)three or four inch diameter polyethylene ASTM F892 corrugated pipe with
a smoothwall interior and fittings
6) any other pipe approved by the executive director

Drainline installation requirements - CORRECT-ANSWERSThe drainline shall
be placed in the media with a least 6" of media between the bottom of the
excavation and the bottom of the drainline. The drainline shall be completely
covered by the media and the drainline perforations shall be below the

, horizontal center line of the pipe. For excavations greater than four feet in
width, the maximum distance between parallel drainlines shall be four feet
(center to center). Multiple drainlines shall be manifolded together with solid
or perforated pipe. Additionally, the ends of the multiple drainlines opposite
the manifolded end shall either be manifolded together with a solid line,
looped together using a perforated pipe and media, or capped.

Permeable soil barrier - CORRECT-ANSWERSGeotextile fabric shall be used as
the permeable soil barrier and shall be placed between the top of the media
and the excavation backfill.
Geotextile fabric shall conform to the following specifications for unwoven,
spun-bounded polypropylene, polyester, or nylon filter wrap

Pumped effluent drainfield - CORRECT-ANSWERSA)Applicability. If the slope
of the site is greater than 2% pumped effluent drainfields shall not be used.
Pumped effluent drainfields may only be used by single family dwellings.
B) Length of distribution pipe. There shall be at least 1,000 linear feet of
perforated pipe for a two bedroom single family dwelling. For each additional
bedroom, there shall be an additional 400 linear feet of perforated pipe. No
individual distribution line shall exceed 70 feet in length from the header.
C)Excavation width and horizontal separation. The excavated area shall be at
least 6" wide. There shall be at least three feet of separation between
trenches.
D)Lateral depth and vertical separation. All drainfield laterals shall be
between 18" and three feet deep. There shall be a minimum vertical
separation distance of one foot from the bottom of the excavation to a
restrictive horizon, and a minimum vertical separation of two feet from the
bottom of the excavation to groundwater

Restaurant/food establishment sewage - CORRECT-ANSWERSWhen designing
for restaurants, food service establishments, or similar activities, the
minimum design strength value shall be 1,200 mg/1 Biochemical Oxygen
Demand (BOD) after a properly sized grease trap/interceptor. It is the
responsibility of the designer to properly design a system which reduces the
wastewater strenth to 140 mg/1 BOD prior to disposal unless secondary
treatment levels are required.

Other high-strength sewage - CORRECT-ANSWERSFor situations where
sewage as defined in this chapter is expected to be a higher strength than
residential sewage, it is the responsibility of the professional designer to
justify sewage design strength estimations and properly design a system
that reduces the wastewater strength to 140 mg/1 BOD prior to disposal
unless secondary treatment levels are required. Residential sewage is
sewage that has a strength of less than 300 mg/1 BOD

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller Elitaa. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $13.99. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

72042 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$13.99
  • (0)
  Add to cart