Alarm switches / sensors shall be installed so that they can be _ and accessible for service and testing. 99-50 5.1.9.1 (15) - Answer-Removable
All master, area, and local alarm systems shall include separate _ indicators for each condition monitored. 99-50 5.1.9.1 (1) - Answer-Visual
All med...
Med Gas Study Guide Worksheet 7 Exam
Questions and Answers
Alarm switches / sensors shall be installed so that they can be _ and accessible for
service and testing. 99-50 5.1.9.1 (15) - Answer-Removable
All master, area, and local alarm systems shall include separate _ indicators for each
condition monitored. 99-50 5.1.9.1 (1) - Answer-Visual
All medical gas alarm systems shall have an _ audible indication for each condition
monitored. 99-50 5.1.9.1 (3) - Answer-Cancelable
Anesthetizing locations where moderate sedation, deep sedation or general anesthesia
is administered, what alarm panels would monitor these locations? 99-52 5.1.9.44 (2) -
Answer-Area Alarm Panel
Area alarm panels for medical gas systems shall indicate when line pressure in the area
being monitored increase or decreases by _ percent. 99-52 5.1.9.4.2 - Answer-20%
Areas for anesthetizing gas delivery shall have the pressure sensors installed on the _
side of the individual room zone valve box assembly. 99-52 5.1.9.4.4 (1) - Answer-
Source or Patient
Computer systems used as a master alarm shall be continuously attended or shall
provide remote signaling of responsible parties through _. 99-52 5.1.9.3.1 (2) - Answer-
Pagers, telephones, auto-dials - any of the above.
High Carbon monoxide level in the medical air system shall indicate at each local alarm
site. At what level shall the alarm activate? 99-53 5.1.9.5.4 - Answer-10 ppm or higher
Ina cylinder supplied medical gas system with reserve, which alarm system(s) will
activate when, or just before, the changeover to the reserve supply occurs? - Answer-
Local and master
Category 1 spaces other than anesthetizing locations shall be located on which side of
the zone valve box assemblies? 99-52 5.1.9.4.4 (1) - Answer-Patient or use side
Initiating devices is remote from the building and the wiring is to run underground to a
junction box. How many sets of wires shall be permitted? 99-51 5.1.9.2.3.1 - Answer-
Single Set
One of the master alarm panels shall be located in the office or work space of the
individual responsible for the maintenance of the medical gas piping system. Where
The benefits of buying summaries with Stuvia:
Guaranteed quality through customer reviews
Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.
Quick and easy check-out
You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.
Focus on what matters
Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!
Frequently asked questions
What do I get when I buy this document?
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
Satisfaction guarantee: how does it work?
Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.
Who am I buying these notes from?
Stuvia is a marketplace, so you are not buying this document from us, but from seller lectknancy. Stuvia facilitates payment to the seller.
Will I be stuck with a subscription?
No, you only buy these notes for $10.49. You're not tied to anything after your purchase.