100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached
logo-home
Alabama Gas Test Exam Questions with Correct Answers $18.49   Add to cart

Exam (elaborations)

Alabama Gas Test Exam Questions with Correct Answers

 0 view  0 purchase
  • Course
  • Gas Master
  • Institution
  • Gas Master

The ____ shall be responsible for the maintenance of fuel gas installations. - Answer-owner or owner agents- 102.3 Maintenance If the permit has not been issued, an application for a permit is considered abandoned _____ days after the date of filing. - Answer-180 days-106.3.2 Time limitation of ...

[Show more]

Preview 3 out of 27  pages

  • September 25, 2024
  • 27
  • 2024/2025
  • Exam (elaborations)
  • Questions & answers
  • Gas Master
  • Gas Master
avatar-seller
lectknancy
Alabama Gas Test Exam Questions with
Correct Answers
The ____ shall be responsible for the maintenance of fuel gas installations. - Answer-
owner or owner agents- 102.3 Maintenance

If the permit has not been issued, an application for a permit is considered abandoned
_____ days after the date of filing. - Answer-180 days-106.3.2 Time limitation of
application

The lowest portion of a floor furnace shall have 12 inch minimum clearance on all sides
except the control side, which shall have a ____ minimum clearance. - Answer-18-609.4
Clearance

Water heaters utilized both to supply potable water and provide hot water for space
heating shall be listed and labeled and shall be installed in accordance with the _____. -
Answer-I.P.C. International Plumbing code- 624.2 Water heaters used for space heating

A drip shall not be be located where condensate is subject to ____. - Answer-Freezing-
408.3 Location of drips

A means to interrupt the electrical supply to an air conditioning appliance shall be
provided ____ and not more than ___ feet from the air conditioner. - Answer-Within
Sight and 50 feet- 627.10 switches in electrical supply

Floor furnaces shall not be installed _____ - Answer-in a concrete floor built on grade.-
609.2 #4 Placement

A yellow insulated copper tracer wire or other approved conductor shall be installed
____ to the underground nonmetallic gas piping. - Answer-Adjacent-404.15.3 tracer

The floor register of a floor furnace is permitted to be installed ____ - Answer-12 inches
from the draperies-609.2 #3 placement

Casing extension boots shall not be installed on a wall furnace unless __ - Answer-
listed as a part of the appliance.-608.5 ducts prohibited

Outside ventilation air shall be supplied to the space containing a recirculating direct
fired industrial heater at a minimum rate of _ com per 1,000 but/h of the rated input of
the heater. - Answer-4-612.5 air supply

Clothes dryer exhaust ducts shall be equipped with a ___ - Answer-backdraft damper-
614.4 exhaust installation

,Vented wall furnaces shall be located so as not to cause a ___ to walls floors
combustible furnishings or doors. - Answer-fire hazard- 608.3 location

Non recirculating direct fired industrial air heaters shall not be used to supply any area
containing ___ - Answer-sleeping quarters-611.2 installation

dryer exhaust systems shall be independent of all other systems and shall convey the
moisture and any products of combustion to the - Answer-outside of the building 614.1
installation

dryer ducts shall not be connected or installed with ___ or other fasteners that will
obstruct the flow. - Answer-sheet metal screws 614.4 exhaust installation

where space for a domestic clothes dryer is provided an ______ system shall be
installed - Answer-exhaust duct 614.6.7 exhaust duct required

the minimum unobstructed total area of the outside and return air ducts or openings to a
forced air warm air furnace shall be not less than __ square inches per 1,000 btu/h
output rating capacity of the furnace - Answer-2-618.2 forced air furnaces

in general return air for a forced air furnace shall not be taken from a ____ - Answer-
Crawl space-618.5 #7 prohibited sources

the required ventilation opening to a sauna room shall not be less than _ inches by _
inches - Answer-4 and 8- 615.7 sauna room

suana heaters shall be equipped with a thermostat that limits the room temp to no more
than ___ degrees Fahrenheit - Answer-194 degrees-615.6 heat and time controls

required outdoor air inlets for a residential forced air heating system shall be covered
with screen having _ inch openings - Answer-1/4 inch-618.6 screen

Appliances regulated by this code shall be ___ and ___ for the application in which they
are used unless otherwise approved in accordance with section 105 - Answer-listed and
labeled-301.3 listed and labeled

the minimum dimension of openings for indoor or outdoor combustion air shall be not
less _ inches. - Answer-3 inches(304.5.3.1)(304.6)

the highest end of the scale for mechanical gauges used to measure test pressures
must not be greater than __ times the test pressure. - Answer-5
times(406.4)testpressuremeasurment

a gas piping system located inside an ____- building is limited to a maximum design
operating pressure of 5 pounds per square inch gage. - Answer-
institutional(402.6)#3Maximujmdesignoperatingpressure

, when a union is provided for an appliance connected by rigid metallic pipe, the union
shall be accessible and located within _ feet of the appliance - Answer-6
feet(411.1.6)Unions

fuel gas piping for other than day gas conditions shall be sloped not less than __ inch in
15 feet to prevent traps - Answer-1/4 inch(408.1)slopes

to allow connection of a pressure measuring instrument a tee fitting with one capped
opening shall be installed not more than __ pipe diameters downstream of an mp
regulator - Answer-10 pipe diameters(410.2)#6MPregulatos

a dedicated gas shut off valve must be located adjacent to the egress door of a
laboratory having __ or more fuel gas outlets - Answer-
2(409.6)shutoffvalveforlaboratories

semirigid metallic tubing used to connect a gas appliance shall not exceed __ feet in
length - Answer-6 feet(411.1)#3Connectingapplaince

the appliance shutoff valve is permitted to be installed at a manifold that is not greater
than _____ from the appliance - Answer-50 feet(409.5.3)Locatedatmanifold

a gas shut off valve complying with ____ is permitted on 5 psig pressure gas lines
without requiring 5 g label - Answer-asme
b16.33(Table409.1.1)ManualGasValveStandards

a gas shut off valve shall be located within ___ of the appliance - Answer-6
feet(409.5.1)locatedwithingthesameroom

self service lp gas dispensing systems for motor vehicles require an emergency shut off
switch located at least 20 feet and not greater than __ from the lp gas dispensing
equipment - Answer-100 feet(412.8)Privatefuelingofmotorvehicles

where there are multiple meters the ___ must mark the piping system supplied by each
meter with an approved permanent identification - Answer-
installer(401.7)Pipingmeteridentification

the volume of gas to be provided must be determined directly from the ___ of appliance
served - Answer-input rating(402.2Maximumgasdemand)

in liquefied pertoleum gas motor vehicle fuel dispensing facilities the hose length shall
not exceed ___ - Answer-18 feet(412.7.2)Hoses

gas piping supports 1/2 inch copper tubing shall be spaced no more then __ - Answer-4
feet apart(415.1)chartintervalofsupport

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller lectknancy. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $18.49. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

75619 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$18.49
  • (0)
  Add to cart