Fire inspectors may want to acquaint fire suppression personnel with proposed building
plans so they can: - answerprovide feedback about problems that may be encountered
during a fire.

Which item would not be considered during a field observation of a site for emergency
access? - answerVerification of code compliance for the storage, handling, and use of
hazardous materials

Private driveways or parking lots may consist of either a __________ skin of asphalt
over the top of gravel or a __________ slab of concrete. - answerThin/Thin

Fire department access is determined by local codes or ordinances to specify: -
answerwidth of roads.

Obstructions to fire department access include all the following except: - answerramps

When evaluating fire access roads, all parts of the building should be accessible with a
__________ foot hoseline. - answer150

Local codes or ordinances should specify driveway and entrance requirements for a
facility based on: - answerthe largest fire apparatus that will be expected to respond to
the occupancy.

Driveway width curves and surfaces should be designed: - answerto accommodate the
turning radius of fire apparatus.

The first design element of a fire department access road surface should be: -
answerstrong enough to handle the weight of a fire apparatus.

During a field inspection, the fire inspector should do all of the following except: -
answerdetermine the cost to the contractor of changes being required by the fire
department.

During plans review, an inspector should determine __________ for apparatus access.
- answerturning radius

The __________ or __________ should specify driveway and entrance requirements
that facilitate access for the largest fire apparatus. - answerModel codes, standards

, An extremely important aspect of Building Codes is the __________ to the site for fire
apparatus and fire fighters. - answeraccessibility

A concern for firefighting personnel at any given location is the ability to place _______
in a position where it can operate effectively during _______. - answerfire apparatus,
emergency operations

In order to ensure that __________ or __________ have appropriate access to the
building, fire lanes may need to be established. - answeraerial apparatus, other fire
equipment

Which of the following best describes a fire hazard involving cooking equipment? -
answerCombustible materials are located within 18 inches of cooking equipment.

The upper and lower concentrations of a vapor that will produce a flame at a given
pressure and temperature are called: - answerflammable and explosive limits.

The percentage of a flammable substance in air that will burn when in contact with an
ignition source best defines: - answerflammable/explosive limit.

Choose the best answer regarding the difference between compressed and liquefied
gases at normal temperatures. Within a pressurized container: - answercompressed
gases are only in a gaseous state.

The agency that regulates the transportation of compressed and liquefied gases is the: -
answerU.S. Department of Transportation (DOT).

To avoid trapping cryogenic liquids in piping, which choice for installed piping is the
safest? - answerA pressure relief device between every two shut-off valves and piping
sloped up from the container.

Cryogenic liquids have a boiling point of: - answer-130 degrees F.

Pyrophoric materials can ignite when they come in contact with: - answerair

The best source of information on a specific hazardous material from the manufacturer
is the: - answerMaterial Safety Data Sheet (MSDS).

An identification system that can be implemented in an area where hazardous materials
are regularly stored and used is the: - answerNFPA 704 system

The Emergency Response Guide is: - answerintended to be carried in every public
safety vehicle in the country.

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller julianah420. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $14.49. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

72042 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$14.49
  • (0)
  Add to cart