100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached
logo-home
ACI WRITTEN EXAM QUESTIONS AND ANSWERS 2024 $17.99   Add to cart

Exam (elaborations)

ACI WRITTEN EXAM QUESTIONS AND ANSWERS 2024

 0 view  0 purchase
  • Course
  • ACI WRITTEN
  • Institution
  • ACI WRITTEN

ACI WRITTEN EXAM QUESTIONS AND ANSWERS 2024

Preview 3 out of 17  pages

  • September 22, 2024
  • 17
  • 2024/2025
  • Exam (elaborations)
  • Questions & answers
  • ACI WRITTEN
  • ACI WRITTEN
avatar-seller
Teacher101
ACI WRITTEN EXAM

A mallet weighing ____ must be used to tap the sides of the bowl after rodding
each layer - ANSWERS-1.25 +-.5 lb



The sample of concrete used in this test must be obtained in accordance with
ASTM satndard _____ - ANSWERS-C172



The max size aggregate allowed for this test method is ______ - ANSWERS-1.5 in
(37.5mm)



If concrete sample has contains aggregates larger than that allowed for the test
what must be done? - ANSWERS-wet sieved over a 1 in (25mm) sieve



When filling the measuring bowl of the air meter the concrete must be placed in
____ layers - ANSWERS-2



What is the specified number of strokes required when rodding each layer of
concrete - ANSWERS-25



It is necessary to tap the sides of the measuring bowl after each layer has been
rodded - ANSWERS-True

,The initial quantitiy of water and alcohol added to the air meter can be directly
poured into the neck of the top section of the air meter - ANSWERS-False, the
funnel must be used



Upon final filling of the air meter with water, what part of the liquid level should
be adjusted to the zero mark on the meter - ANSWERS-Bottom of the meniscus



How long should the air meter be inverted and agitated - ANSWERS-No more than
five seconds at a time for 45 seconds



How many times does the rolling operation occur - ANSWERS-a minimum of 2, a
max of 3



Why is the isopropyl alcohol added to the meter - ANSWERS-To dispel any foam
that may be on the surface of the water



The direct reading of the final liquid level in the neck of the air meter is estimated
to the nearest _____ - ANSWERS-0.25 percent



If the air content is greater than 9% range of the meter then ____ - ANSWERS-
Calibrated cups of water are added to bring liquid in range



In order for an initial meter reading to be valid the meter must not be leaking the
liquid level must stabilize within 6 minutes and the foam on the surface of the
liquid must not be greater than 2 full percent division - ANSWERS-True

, If less than 1.25 L (2.5 pt) of alcohol are used, the air content is always indicated
by the final meter reading - ANSWERS-False, if air content is more than 9 percent
the number of calibrated cups of must be added



if more than 1.25 L (2.5pt) of alcohol are used the final meter reading is adjusted
using - ANSWERS-a correction factor



When large amounts of alcohol are used the direct reading will tend to indicate a
______ air content - ANSWERS-Higher



The sensor of the temperature measureing device shall be submerged a minimum
of ____ in - ANSWERS-3 (75mm)



The temperature measureing device shall have a capacity of measuring
temperature of freshly mixed conrcrete to +-_____ degrees F throught a range of
_____ - ANSWERS-1(.5 degrees C), 30-120 (0-50 degrees C)



The temperature measuring device shall be calibrated____, or whenever there is
a question of _____ - ANSWERS-annually, accuracy



The temp of concrete may be measured in a wheelbarrow - ANSWERS-true



the temp of concrete may be measured in a wall form - ANSWERS-true

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller Teacher101. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $17.99. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

76658 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$17.99
  • (0)
  Add to cart