HVAC JOURNEYMAN EXAM AND PRACTICE EXAM 150 QUESTIONS AND CORRECT DETAILED ANSWERS WITH RATIONALES Defects on gas piping or fittings shall be _____.(A) repaired(B) replaced or repaired and retested(C) repaired by a certified welder(D) ignored, as the operating pressure is much less than the ai...

[Show more]

Preview 2 out of 15  pages

  • September 18, 2024
  • 15
  • 2024/2025
  • Exam (elaborations)
  • Questions & answers
  • 2024/2025
  • 2024/2025
avatar-seller
EmillyCharlotte
TITLE: EMILLYCHARLOTTE 2024/2025 ACADEMIC PERIOD
OWNER: EMILLYCHARLOTTE
COPYRIGHT STATEMENT: ©2024 EMILLYCHARLOTTE. ALL RIGHTS RESERVED
FIRST PUBLISHED: SEPTEMBER 2024


HVAC JOURNEYMAN EXAM 2024-2025 AND PRACTICE
EXAM 150 QUESTIONS AND CORRECT DETAILED
ANSWERS WITH RATIONALES



Defects on gas piping or fittings shall be _____.(A) repaired(B) replaced or repaired and

retested(C) repaired by a certified welder(D) ignored, as the operating pressure is much

less than the air test. - Answer✔️✔️-B. Fitting shall be replaced or repaired and retested.

UMC Section 1316.4.3

Every absorption refrigerating system supported from the ground shall rest on a

concrete slab extending not less than _____ the adjoining ground level.(A) 3 inches

below(B) 3 inches above (C) 6 inches below(D) 6 inches above. - Answer✔️✔️-B. Slab

extending not less than 3" above the adjoining ground level. UMC Section 1106.2

Any part of a venting system installed at an angle greater than 45 degrees from the

vertical is considered by code to be _____.(A) vertica(B) horizontal l (C) a flat vent (D)

an offset vent - Answer✔️✔️-B. any part of the venting installed at an angle GREATER

than 45 degrees is considered by this code to be Horizontal UMC Section 802.6.1.1

Listed transition ducts f or clothes dryers shall not exceed_____ feet in length. A.3 B.4

C.5 D.6. - Answer✔️✔️-D. Dryers shall not exceed 6 feet in length. UMC Section

504.3.2.1

, TITLE: EMILLYCHARLOTTE 2024/2025 ACADEMIC PERIOD
OWNER: EMILLYCHARLOTTE
COPYRIGHT STATEMENT: ©2024 EMILLYCHARLOTTE. ALL RIGHTS RESERVED
FIRST PUBLISHED: SEPTEMBER 2024
Industrial product-conveying ducts and their fittings for abrasive and nonabrasive dust

or solid materials shall be constructed of _____.(A) sheet meta(B) polyvinyl chloride l

(C) fiberglass (D) A and C apply - Answer✔️✔️-A. Shall Be Constructed of sheet metal.

UMC Section. 5 0 6.1

Industrial product-conveying ducts and their fittings for abrasive and nonabrasive dust

or solid materials shall be constructed of _____.(A) sheet metal ((B) polyvinyl chloride

C) fiberglass (D) A and C apply - Answer✔️✔️-A 511.2

Unlisted vented gas fireplaces shall have a clearance at the sides and rear of not less

than _____ inches. Is the Answer: A. 10" B. 12" C 16" D. 18". - Answer✔️✔️-D. clearance

of an unlisted vented gas fireplace at the sides and the rear not less than 18". UMC

Section 908.2(B)

Leaks in gas piping shall be located _____.(A) with a sniffer(B) with a presto-lite flame

(C) with a noncorrosive leak-detecting fluid (D) by increasing the air pressure during a

test until the leaks are heard as a whistle. - Answer✔️✔️-C. leaks in a gas piping shall be

located with a non corrosive leak detecting fluid. UMC Section 1316.4.2

Condensate drain piping shall have a slope of not less than _____ inch per foot. A 1⁄8"

B.¼" C.½" D. 1" - Answer✔️✔️-A. Slope of not less than 1/8" per foot. UMC Section 309.1

The minimum gauge or size steel wire used to support horizontal metal ducts 10 inches

or less in size is _____. A.14 AWG B.16 AWG C.18 AWG D.20 AWG - Answer✔️✔️-C.

18 Minimum Gauge note: AWG is the abbreviation for "gauge size" Table 6-7(B)

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller EmillyCharlotte. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $9.99. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

84866 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$9.99
  • (0)
  Add to cart