What division is mechanical - - Division 23

- how many Btu/H in a ton - - 12000

- What is comfortable relative humidity? - - 50%

- Air velocity - - the speed at which air moves from one point to another

- what is ideal air movement - - 40fpm

- What is the most common duct material - - sheet metal, measured in
gauge (smaller number thicker material)

- Why insulate duct work - - Condensation

- What is the average CO2 level for good indoor air quality? - - 800

- Make up air - - Air supplied to a space to replace exhausted air

- exhaust air - - Any foul or unwanted air removed from a space by
mechanical means.

- What is the normal building space requirement for fresh outside air - - 20
cubic feet per minute per person in the space

- ASHRAE - - American Society of Heating, Refrigerating and Air-
Conditioning Engineers

- 5 requirements for comfort - - proper temperature, humidity, circulation,
filtration, ventilation

- Dry Bulb Temperature - - the measurement of sensible heat

- Relative Humidity (RH) - - the amount of water vapor present in air
expressed as a percentage of the amount needed for saturation at the same
temperature.

- Dew point(dp) - - the temperature below which moisture in the air begins
to condense

, - Enthalpy (h) - - The total heat contained in a substance measured from a
baseline of 32 degrees farenheit

- Where is relative humidity found on a psychometric chart? - - the curving
lines that run from the bottom left side of the chart up to the right

- forced air system - - fuel heats air, which is blown through ducts and
vents; cool air is returned to the furnace to be reheated

- Three must common types of furnaces - - upflow, horizontal, and downflow
(counterflow)

- Upflow Furnace - - return air is supplied at the bottom of the unit and the
heated air is delivered to the bonnet above the furnace where it is
distributed through ductwork

- horizontal flow furnace - - furnace in which heated air flows horizontally as
it leaves the furnace

- Downflow Furnace - - furnace is typ. located on first floor and heated air is
pushed down into ductwork located in a crawl space or basement.

- Blower - - pump-like mechanism which generates airflow

- blowers used in forced-air systems - - propeller, centrifugal, axial

- propeller blower - - blades mounted on a central bulb

- centrifugal blower - - Consists of a scroll, blower wheel, shaft, and inlet
vanes

- axial flow blower - - -Consists of a blower wheel that works like turbine
wheel
-Used in medium to high pressure forced air heating systems

- Static Pressure - - pressure that acts through weight only with no motion

- heat exchanger - - A device that transfers heat from one substance to
another without allowing substances to mix (think radiator)

- Low-efficiency filter - - 40% of large particulate matter

- Medium efficiency filter - - 40 to 80% of common-size particulate matter

- High-efficiency particulate air (HEPA) filters - - 80 to 90 % of small
particulate matter

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller Nursephil2023. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $10.49. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

85169 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$10.49
  • (0)
  Add to cart