CSST BUILDING INSPECTION EXAM NEWEST ACTUAL
EXAM COMPLETE 120 QUESTIONS AND CORRECT
DETAILED ANSWERS (VERIFIED ANSWERS) |ALREADY
GRADED A+
Guards shall be required for open sided walking surfaces more than _
above the
floor or grade below. - ANSWER: 30in

Group M occupancy - ANSWER: MERCANTILE - Display and sale of merchandise

When required under concrete slabs, lap joints for polyethylene vapor retarders shall
not be less than - ANSWER: 6in

Audible alarm notification appliances shall provide a sound pressure level of.
decibels above the average ambient sound or _
_decibels above the maximum sound
level having a duration of at least 60 seconds, whichever is greater - ANSWER: 15 - 5

Particle board used as underlayment shall be at least ___ thick. - ANSWER: .25in

A bakery constructed of type IIIB construction, with an automated sprinkler
throughout shall not be more than ___ stories in height. - ANSWER: 3

What is the minimum nominal thickness of masonry chimney walls - ANSWER: 4 in

How far can a decorative trim project in to the required width of an exit pathway -
ANSWER: 1.5in

A 6 foot tall, 7-1/2 inch thick concrete wall with 5 feet of unbalanced backfill shall
have which of the following as minimum reinforcement? - ANSWER: Plain concrete

Work must commence on the site within_____after a permit is issued or it becomes
invalid. - ANSWER: 180 days

What is the minimum allowable thickness of a concrete floor slab, supported directly
on the ground? - ANSWER: 3.5 in

A mezzanine shall not exceed____
of the floor area of that room or space in which
they are located. - ANSWER: 1/3

Who is responsible for the maintenance of an existing building or structure? -
ANSWER: The owner or the owner,s agent

, The top of any exterior foundation shall extend above the elevation of the street
gutter at a point of discharge at least - ANSWER: 12 in

The maximum dimension permitted in the above image - ANSWER: 34 In

Combustible interior decorative trim, excluding handrails and guardrails, shall be
limited to a maximum of _ _of the aggregate wall or ceiling area in which it is located
- ANSWER: 10%

5.7 sq ft - ANSWER: emergency escape and rescue openings shall have a minimum
net clear opening of

1 hour - ANSWER: in an office building of type II construction, what is the minimum
required fire resistance rating of the interior baring wall

3 in - ANSWER: how far shall a 2 x 8 floor joist bare on an 8 inch CMU foundation wall

16 in - ANSWER: foundation walls of rough or rubblestone must be at least __ thick

2 hours - ANSWER: in a four story office building the elevator services the entire
building including the basement, what is the minimum fire resistance rating for the
machine room that is attached and services the elevator?

24 ft - ANSWER: what is the maximum amount of height of a solid roof sign
(measured from the roof surface)?

1 hour - ANSWER: where a fire barrier is utilized to separate a Group U occupancy
into multiple fire areas, what is the minimum fire resistance rating of the fire barrier?

1 in - ANSWER: a thermal barrier is not required form foam plastic installed in a
masonry or concrete wall, floor or roof system where the foam plastic insulation is
covered on each face by a minimum of ___ thickness of masonry or concrete

1 hour - ANSWER: what is the minimum fire protection rating for a fire door
assembly in a 1 hour rated exit enclosure

6 - ANSWER: the smoke level in a means of egress serving a smoke protected
assembly seating area is intended to be located a minimum of ___ feet above the
floor of the means of egress

8 ft - ANSWER: covered walkways implemented to protect the public during
construction shall have a clear height of not less than ____

30 in - ANSWER: A ___ minimum clear headroom in the attic space shall be provided
at or above the access opening

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller maxmaxwellmm254. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $17.99. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

75632 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$17.99
  • (0)
  Add to cart