Which is not an element for comfort?
Temp, Noise, Humidity, or Circulation? - CORRECT ANSWER-Noise
Normal ventilation for a building is: - CORRECT ANSWER-20 CFM per person
Comfort for heating and cooling is usually attained with a relative humidity of what percentage? - CORRECT ANSWER-50%
...
CM 411: Specialty Contracting HVAC &
Plumbing Midterm Actual Exam
Questions With Real Answers
Which is not an element for comfort?
Temp, Noise, Humidity, or Circulation? - CORRECT ANSWER-Noise
Normal ventilation for a building is: - CORRECT ANSWER-20 CFM per person
Comfort for heating and cooling is usually attained with a relative humidity of what
percentage? - CORRECT ANSWER-50%
Water flow is typically expressed in which units? - CORRECT ANSWER-Gallons per
minute
A device that removes moisture from air by causing moisture to condense is called a: -
CORRECT ANSWER-DEhumidifier
Liquids traveling through a steel pipe have pressure loss due to which two factors? -
CORRECT ANSWER-friction with the interior walls of the pipe, and changes in direction
at elbows and T junctions
Air filters are placed prior to air movement equipment in order to: - CORRECT
ANSWER-Keep material and debris from entering air movement equipment
What indicates when moisture will start to condense? - CORRECT ANSWER-Dew point
Sensible heat is measured using: - CORRECT ANSWER-Dry bulb temperature
,If the inlet to the pump does not have enough head, what will happen? - CORRECT
ANSWER-The pump will begin to cavitate
True or False: Heating and cooling loads occur because of a difference between the
indoor and outdoor temperature, infiltration in the building, and internal loads -
CORRECT ANSWER-True
True or False: The winter dry bulb temperature is the coldest temperature expected in
January for any given location - CORRECT ANSWER-False
True or False: Exposed surfaces are building surfaces that are exposed to outdoor
temperatures - CORRECT ANSWER-True
True or False: Net wall area is the area of wall after the area of windows, doors, and
other openings have been subtracted from gross wall area - CORRECT ANSWER-True
True or False: When calculating the area of a ceiling, all overhangs are included -
CORRECT ANSWER-False
Estimating the number of people occupying a residential building and estimating the
number of people occupying a commercial building are done with the same method -
CORRECT ANSWER-False
True or False: Any device that produces heat inside a building must be compensated for
by a cooling load - CORRECT ANSWER-True
True or False: A conduction factor (U) is a number that represents the amount of heat
that flows through a building because of a temperature difference - CORRECT
ANSWER-True
True or False: Infiltration occurs when air flows through a furnace filter - CORRECT
ANSWER-False
, True or False: The volumetric flow rate of ventilation air required for a building is based
on volumetric flow rate of air required per person in the building - CORRECT ANSWER-
True
True or False: The amount of heat given off from building occupants varies depending
on the activity of the occupants - CORRECT ANSWER-True
True or False: Equivalent temperature difference is the design temperature difference,
which is adjusted for heat gain from appliances - CORRECT ANSWER-False
When the sun shines on an exterior surface of a building or opaque objects inside a
building, the solar energy becomes chemical energy - CORRECT ANSWER-False
Variables and __________ are entered on a load form and are used to calculate heat
losses and gains for a building - CORRECT ANSWER-Factors
A summer indoor design temperature of _____ degrees F is usually selected to provide
comfort for a normally clothed person during the summer - CORRECT ANSWER-75
Summer outdoor design temperatures are the warmest temperatures expected in an
area during ____% of the summer - CORRECT ANSWER-95
________s are written supplements to plans that describe the materials used for a
building - CORRECT ANSWER-Specifications
For cooling load calculations, the area of windows and glass doors is calculated and
entered on the form according to _____. - CORRECT ANSWER-exposure
The _____ of the ceiling and floor is found by multiplying the dimensions of the rooms -
CORRECT ANSWER-area
______ is the opening around windows, door, and other openings in a building such as
between the foundation and framework of the building - CORRECT ANSWER-Crackage
The benefits of buying summaries with Stuvia:
Guaranteed quality through customer reviews
Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.
Quick and easy check-out
You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.
Focus on what matters
Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!
Frequently asked questions
What do I get when I buy this document?
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
Satisfaction guarantee: how does it work?
Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.
Who am I buying these notes from?
Stuvia is a marketplace, so you are not buying this document from us, but from seller remojudytask. Stuvia facilitates payment to the seller.
Will I be stuck with a subscription?
No, you only buy these notes for $11.19. You're not tied to anything after your purchase.