WELL AP v2 – Air Exam Questions and
Answers

What are the acceptable thresholds for particulate matter for all spaces except
Commercial Kitchens and Industrial spaces in unpolluted regions in Part 1: Meet
Thresholds for Particulate Matter of Feature A01: Air Quality? - Answer -PM2.5: 15
ug/M or lower and PM10: 50 ug/m or lower.

In Feature A01: Air Quality, what is the acceptable threshold for particulate matter in
commercial kitchens? - Answer -PM 2.5: 35 ug/M or lower

What is the verification method for Part 1: Meet Thresholds for Particulate Matter,
Option 1 of Feature A01: Air Quality in all spaces except commercial kitchens and
industrial spaces? - Answer -Performance Test

In a project with regularly occupied spaces at or below grade, where should the radon
test be performed for Feature A01: Air Quality? - Answer -At or below grade.

At an existing office building campus, signage indicating an outdoor smoking ban is
posted at all building entrances. The signs indicate the ban on smoking within 7.5 m (25
ft) of all building entrances, operable windows, building air intakes, and regularly
occupied exterior building spaces. What signage must be added to the courtyard areas
more than 7.5 m (25 ft) from building entrances to meet the requirements of Part 2:
Prohibit Outdoor Smoking of Feature A02: Smoke-Free Environment? - Answer -The
hazards of smoking, posted at ground level every 30 m (100 ft) along walkways.

An office building's air quality test has met the minimum requirement for ozone in Part 3:
Inorganic Gases of Feature A01: Air Quality. What other minimum standard is also
required in Part 3 of that feature for WELL Certification? - Answer -Carbon Monoxide:
10 ug/m or lower

A new office building in Seattle is in its post-occupancy performance test phase by a
WELL Performance Testing Agent. What is the minimum threshold for formaldehyde in
Part 2: Meet Thresholds for Organic Gases of Feature A01: Air Quality? - Answer -50
ug/m3 or lower

, An office building has several balconies and a rooftop accessible by building occupants.
According to Part 2: Prohibit Outdoor Smoking of Feature A02: Smoke-Free
Environment, there must be signage in all outdoor areas within the project's boundary.
What is the verification method required for this feature? - Answer -On-site Photographs

What is the maximum level of carbon monoxide for all spaces in Part 3: Meet Threshold
for Inorganic Gases of Feature A05: Enhanced Air Quality? - Answer -7 mg/m3 or lower

In mechanically ventilated spaces, ventilation systems are designed to meet supply and
exhaust rates set in one or more of the following verification guidelines: - Answer -
ASHRAE 62.1-2010, ASHRAE 62.2-2016

In naturally ventilated spaces with no mechanical ventilation, what requirements must
be met for at least 90% of the project? - Answer -CIBSE AM10

The use of UVGI is required for which of the following features? - Answer -Feature A14:
Microbe and Mold Control

What are the minimum dimensions required for entryway walk-off systems? - Answer -
At least the width of the doorway and 3m (10ft) long in the direction of travel.

An office space is being constructed on the 5th floor of a downtown tower. According to
Feature A03: Ventilation Design, when is the ideal time to perform testing and balancing
on the HVAC system in this project? - Answer -After project occupancy.

In Part 2: Meet Enhanced Thresholds for Organic Gases of Feature A05: Enhanced Air
Quality, which thresholds are to be met? - Answer -Formaldehyde 9 ug/m3 or lower &
Toluene 300 ug/m3 or lower.

For naturally ventilated spaces, it is necessary to ensure that adequate outdoor air
quality & _____________ are met. - Answer -Noise levels

Since it is difficult to test for every potential pollutant in the indoor air of a building, what
easily detectable pollutant serves as a proxy for other indoor pollutants? - Answer -
Carbon Dioxide

In Tokyo, a new mixed-use complex is being planned to replace a retired railyard. The
ambient air has a high concentration of small particulates. According to Feature A12: Air
Filtration, what is the project team required to install in order to protect the building
occupants from exposure to the particulates? - Answer -Adequate media filters based
on the annual average PM 2.5 of the area.

A new office building in San Diego has an average annual PM 2.5 of 21 ug/m. What
type of filter is required to meet Part 1: Implement Particle Filtration of Feature A12: Air
Filtration? - Answer -MERV 12 or M6

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller millyphilip. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $11.49. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

72349 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$11.49
  • (0)
  Add to cart