OECP/NCCO Exam Questions With Correct And Revised Answers. Which of the following OSHA regulations, governing suspended personnel platforms? - answerOSHA 1926.1431 According to ASME B30.3, the prohibited zone for power lines that are 60 kV is. - answer15 ft The OSHA construction standards for...

[Show more]

Preview 2 out of 5  pages

  • September 7, 2024
  • 5
  • 2024/2025
  • Exam (elaborations)
  • Questions & answers
  • OECP
  • OECP
avatar-seller
Brightstars
©THEBRIGHTSTARS 2024



OECP/NCCO Exam Questions With Correct
And Revised Answers.


Which of the following OSHA regulations, governing suspended personnel platforms? -
answer✔✔OSHA 1926.1431

According to ASME B30.3, the prohibited zone for power lines that are 60 kV is. - answer✔✔15
ft

The OSHA construction standards for rigging equipment is? - answer✔✔1926.251
According to ASME B30.3 what is the minimum pitch diameter for a load block sheaves? -
answer✔✔Not less than 15 times rope diameter

According to OSHA, a periodic inspection is? - answer✔✔Monthly to annually

Per OSHA, crane hooks must not be twisted in excess of? - answer✔✔10 degrees

Per OSHA crane hooks throat opening must not exceed? - answer✔✔15% of its original size
According to OSHA and ASME B30.3 you should always have at least how many wraps on a
hoist drum? - answer✔✔2
Per ASME, what is the minimum allowable distance from the crane and powerlines under 50
kV? - answer✔✔10ft
According to ASME B30.3 how many randomly broken wires in one way, must there be to
remove a running wire rope shit from service - answer✔✔12

Per ASME what is the minimum design factor required for a boom hoist rope? - answer✔✔3.55
Per ASME, how many broken wires must be present in one strand of one lay for running wire
rope to be removed from service? - answer✔✔4

According to ASME B30.3, crane should be plumbed to... - answer✔✔1:500
According to ASME B30.3, the Raiders load understand the conditions shall not exceed _____ of
calculated tipping loads. - answer✔✔63%

, ©THEBRIGHTSTARS 2024

Bolt connections for tower sections must use high tensile strength nuts with ratings of? -
answer✔✔12
According to the NCCCO tower crane reference manual, how many safety turns must be left on
the hoist drum when the load hook is in its lowest position? - answer✔✔3
According to the NCCCO tower crane reference manual when possible, installing the hoist wire
rope on a tower crane you should wind the rope with approximately how much of the maximum
permissible load? - answer✔✔10%

What grade of alloy steel chain should be used for crane, hoisting slings. - answer✔✔80 OSHA
1910.184
According to ASME B30.3, using rotation resistant running rope on a tower crane how many
broken wires and six wrote diameters can you have to leave in service? - answer✔✔1
According to ASME B30.3 which inspection does not require records to be kept? -
answer✔✔Frequent
According to ASME B30.3 a periodic inspection of a tower crane wire rope shall be performed
at least? - answer✔✔Annually

If you have a core failure in a wire rope, a common result is? - answer✔✔Reduction in diameter
According to OSHA when a wire rope bridle is used to connect the personnel platform to the
load line. Each bridal leg shall be connected to a? - answer✔✔MasterLink
ASME B30.3 states, rated Loads when wind is considered, the combined effects of static, inertial
and wind shall not exceed ___ of calculated loads. - answer✔✔77%
According to ASME B30.3 a class _____ fire extinguisher shall be kept in the cab or on the
machinery platform. - answer✔✔10 BC
According to OSHA, a class _____ fire extinguisher shall be kept in the cab, or on the machinery
platform. - answer✔✔5 BC or higher
According to ASME B30.3, a frequent inspection and normal service conditions must be
performed: - answer✔✔Weekly to monthly
According to ASME B30.3, a frequent inspection in heavy service conditions must be
Performed: - answer✔✔Daily to weekly
According to ASME B30.3 a periodic inspection and light service conditions must be performed:
- answer✔✔Annually
According to ASME B30.3, a periodic inspection, and normal service conditions must be
performed: - answer✔✔Semi annually to annually

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller Brightstars. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $10.49. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

81531 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$10.49
  • (0)
  Add to cart