Exam (elaborations)
ARRT TEST PREP, LIMITED X-RAY CORE QUESTIONS AND ANSWERS WITH SOLUTIONS 2024
ARRT TEST PREP, LIMITED X-RAY CORE QUESTIONS AND ANSWERS WITH SOLUTIONS 2024
[Show more]
Preview 4 out of 46 pages
Uploaded on
September 6, 2024
Number of pages
46
Written in
2024/2025
Type
Exam (elaborations)
Contains
Questions & answers
Institution
Arrt
Course
Arrt
$15.99
Also available in package deal from $45.50
100% satisfaction guarantee
Immediately available after payment
Both online and in PDF
No strings attached
Also available in package deal (1)
$ 306.28
$ 45.50
22 items
1. Exam (elaborations) - Arrt practice questions and answers with solutions 2024
2. Exam (elaborations) - Arrt mock exam – questions and answers with solutions 2024
3. Exam (elaborations) - Arrt practice test 2 questions and answers with solutions 2024
4. Exam (elaborations) - Arrt practice exam – core questions and answers with solutions 2024
5. Exam (elaborations) - Radiology exam review [arrt] questions and answers with solutions 2024
6. Exam (elaborations) - Arrt test prep, limited x-ray core questions and answers with solutions 2024
7. Exam (elaborations) - Arrt vi exam questions and answers with solutions 2024
8. Exam (elaborations) - Arrt prep exam 2 questions and answers with solutions 2024
9. Exam (elaborations) - Mosby's arrt chapter 2: practice exam questions and answers with solutions 2024
10. Exam (elaborations) - Radiologic technology arrt review questions and answers with solutions 2024
11. Exam (elaborations) - Arrt practice - digital radiography questions and answers with solutions 2024
12. Exam (elaborations) - Lmrt arrt exam questions and answers with solutions 2024
13. Exam (elaborations) - Arrt radiography exam review (1-200) questions and answers with solutions 2024
14. Exam (elaborations) - Lmrt state exam prep questions and answers with solutions 2024
15. Exam (elaborations) - Limited scope of radiography practice exam questions and answers with solutions 2024
16. Exam (elaborations) - Arrt board exam questions and answers with solutions 2024
17. Exam (elaborations) - Arrt vascular interventional mock exam questions and answers with solutions 2024
18. Exam (elaborations) - Arrt patient care review questions and answers with solutions 2024
19. Exam (elaborations) - Arrt mri mock registry questions and answers with solutions 2024
20. Exam (elaborations) - Arrt mock registry questions and answers with solutions 2024
21. Exam (elaborations) - Mock final exam-general core of radiography (limited scope) questions and answers wit...
22. Exam (elaborations) - Arrt prep exam 5 questions and answers with solutions 2024
Show more
ARRT TEST PREP, LIMITED X-RAY CORE
QUESTIONS AND ANSWERS WITH
SOLUTIONS 2024
MainTpropertyTofTx-radiationTthatTmakesTitTpotentiallyThazardousTisTitsTabilityTto?T-TANSWERTIonizeT
DescribeTtheTdamageTpotentialTofTionization?T-
TANSWERTChainTreactionTinTtheThumanTbodyTthatTmayTeventuallyTcauseTbiologicTdamage.TX-
raysTareTfromTtheTElectricTMagneticTSpectrumTorTradiationTenergyTandTisTconsideredTharmfulTinThighTenerg
yTranges.
WhatTisTtheTmostTlikelyTpotentialThazardTworkingTwithTdiagnosticTradiology?T-TANSWERTCarcinogenesisT-
TStochastic/Non-ThresholdTEffect
.1TRemT=T?TSeivertT-TANSWERT1TSievert
0.1TGrayT=T?TRadT-TANSWERT10TRad
1TGrayT=T?TRadT-TANSWERT100TRad
WhatTisTAplasticTAnemia?TWhenTdoseTitToccur?T-TANSWERTAllTtypesTofTbloodTcells:TRedT&TWhite
25TRads
ATdecreaseTinTbloodTcountTisTtheTearliestTresponseTseenTtoTdoseTradiation.TItTcanToccurTatTdoseaseTasTlowTa
s?T-TANSWERT25TRadsTorT.25TGray
WhatTisTCataractogenesis?T-TANSWERTProcessTofTCataractTFormation
CataractogenesisToccursTafterTacuteTorTchronicTexposuresTofThowTmanyTRads?T-TANSWERT200TRads,T2TGray
SkinTEyrythemiaT(SkinTRedning)ToccursTabove?T-TANSWERTAboveT200TRad,T2TGray
,TemporaryTSterilityToccursTinTtheTadultTmaleTatTacuteTdosesTofThowTmanyTRads?T-
TANSWERT250TRads,T2.5TGray
PregnantTradiographerTshould?T(3)T-TANSWERTAlwaysTpracticeTTDS
HasTlegalTrightTforTre-assignmentTofTduty
NeverTconfuseTcollarTbadgeTwithTwaistTbadge
MonthlyTdosimetryTreportsTisTbasedTonTwhat?T-TANSWERTOCCUPATIONALTexposuresTonly.
MonthlyTDosimeterTreportsTdoesTNOTTinclude?T-TANSWERTNaturalTorTBackgroundTRadiation
WhatTisTtheTrecommendedTmonthlyTdose-equivalentTlimitTforTtheTfetusTinTtheTthirdTtrimester?T-
TANSWERT0.5TmSv
.05TRem
NRCPT116
RadiationTworkersTcumulativeTdose-equivalentTlimitTisTdeterminedTby?T-TANSWERTAgeTxT10TmSvT
AgeTxT1TRem
NCRPT110
WhatTisTtheTOccupationalTradiationTdoseTequivalentTlimitTforTstochasticTeffectsTtoTtheTwholeTbody?T-
TANSWERT50TmSvT(5TRem)
WhenTusingTaTC-ArmTmobileTunit,TtheTintensificationTtowerTshouldTbe?T-
TANSWERTAsTcloseTasTpossibleTtoTtheTpatientTtoTreduceTpatientTdoseTandTunnecessaryTmagnification.
RadiationTexposureTinTairT=T?T-TANSWERTRoentgensT-TIonizationTinTairTdoseTmeasurement.
ElectricalTcurrentTbeingTgeneratedTbyTaTchargeTcreatedTinTairTthruTionizationTbyTx/gammaTradiationTisTcalle
dTa?T-TANSWERTIonTChamber
,TheTquantityTofTradiationTexposureTmeasuredTbyTanTionizationTchamberTwouldTbe?T-
TANSWERTCoulomb/Kilogram
TheTC/KgTorTRTisTusuallyTtheTunitTmeasuredTin?T-TANSWERTAirTdose
ListTtheT3TmeasurementsTthatTareTmoreTappropriateTforTmeasuringTabsorbedTdosesTforTradiationTorToccup
ationalTdose?T-TANSWERTGrayT(1)T-TRadT(100)T
SeivertT(1)T-TRemT(100)
CurieT-TBacquerel
WhatTtypeTofTchangesTareTusedTtoTmeasureToccupationalTdose?T(3)T-TANSWERTScintillation
Biological
Chemical
ExampleTofTpersonnelTmonitorTthatTmeasuresTradiationTthruTchemicalTchangeTreaction?T-
TANSWERTFilmTBadgeT-TOperateToffTGurney-MottTtheory.
ExplainTtheTGurney-MottTTheory...?T-TANSWERTDescribesThowTanTx-
rayTphotonTchangesTsilverThalideTintoTatomicTsilverTinTtheTfilmTemulsion--aTdefiniteTchemicalTchange.
HowTlongTcanTaTfilmTbadgeTbeTworn?T-TANSWERTNoTmoreTthanTaTmonth
WhyTshouldn'tTfilmTbadgesTbeTwornTgreaterTthanTaTmonth?T-
TANSWERTExtremeTsensitivityTtoTenvironmentalTconditions.
TLD'sToperateTthru?T-TANSWERTLuminescenceT(NOTchemicalTrx'sToccur)
PocketTdosimetersTcanTonlyTworkTfor?T-TANSWERT1TdayTandTmustTbeTresetTeveryday.
UpperTreadingTlimitTofT200-300Trads
, PocketTdosimeterTuses?T-TANSWERTElectricalTcurrentTasTaTmeasurementTofTcharge.
TheTtypeTofTpersonnelTmonitorTthatTcouldTbeTwornTtheTlongestTisTthe?T-TANSWERTOSD
OpticalTstimulatedTdetectorTcanTbeTwornTupTto?T-TANSWERT3TmonthsTandTbeTsensitiveTtoT2TmR
LeakageTradiationTshouldTNOTTexceedThowTmuchTmRTatT1TmeterTfromTtheTscource?T-
TANSWERT100TmRTperThr
0.1TRadTperThr
NCRPT102
AccordingTtoTBushong,TtabletopTintensityTshouldTNOTTexceedTwhat?T-
TANSWERT2.1TmRTperTminTforTeachTmAToperatingTatT80TkVp.
UnderTnormalTmodesTofToperation,TfluoroscopicTproceduresTshouldTNOTTexceed?T-
TANSWERT10TRenkensTperTmin.
WhatTdoesTGSDTstandTfor?T-TANSWERTGeneticTSignificantTDose
WhatTisTGSD?T-
TANSWERTAverageTgonadalTdoseTreceivedTbyTanTexposedTpopulation.TItTisTusedTtoTestimateTtheTgeneticTim
pactTofTmedicalTradiationTdoseTonTtheTentireTpopulation.
BeamTlimitingTdevicesTwill?T(3)T-TANSWERTImproveTimageTquality
ReduceTpatientTdose
ReduceTscatterTradiation
TheTpurposeTofTreducingTaddedTfiltrationTisTtoTreduceTradiationTdoseTto?T-TANSWERTPatientsTskin