Property and Building Inspection Module II Questions With correct Answers 15 amp breakers use what gauge wire? - Answer-14 Gauge /.20 amp breakers use what gauge wire? - Answer-12 gauge /.30 amp breakers use what gauge wire? - Answer-10 gauge /.40 amp breakers use what gauge wire? - Ans...

[Show more]

Preview 2 out of 9  pages

  • September 5, 2024
  • 9
  • 2024/2025
  • Exam (elaborations)
  • Questions & answers
  • Property and Building Inspection Module II
  • Property and Building Inspection Module II
avatar-seller
kartelo
15 amp breakers use what gauge wire? - Answer-14 Gauge

/.20 amp breakers use what gauge wire? - Answer-12 gauge

/.30 amp breakers use what gauge wire? - Answer-10 gauge

/.40 amp breakers use what gauge wire? - Answer-8 gauge

/.A 14-guage copper wire is protected by a 20amp fuse. You should report that -
Answer-this is a defect, and recommend improvement.

/.A copper wire at least #_____ AWG must connect the structural rebar within the pool
structure and deck, wet niche fixtures of underwater lighting, slides, diving boards,
ladders, pumps and their associated equipment, and any other exposed metal
apparatus within ______ feet of pool walls. - Answer-#8 and 5 feet

/.A kitchen exhaust using a blow is more efficient than one using a fan. T or F - Answer-
True

/.A traditional whole-house fan is a large ____ to ____ inch diameter fan that is installed
in the ceiling usually, in a central hallway. - Answer-24-36 inches

/.A vapor retarder is designed to, restrict vapor diffusion. T or F - Answer-True

/.After entering the service box, the neutral service entrance conductor should - Answer-
connect to the terminal with the grounding electrode and the service neutral.

/.Air leakage from ducts is a common and important problem. T or F - Answer-True

/.All irrigation systems must be designed, installed, maintained, altered, repaired,
serviced and operated in a manner that promotes: - Answer-Water Conservation

/.All new irrigation systems must include which of the following? - Answer-A rain sensor

/.All of the following are common drainage piping problems EXCEPT - Answer-Clay tile
piping buried in the soil.

Common problems would be:
Missing or inaccessible clean-outs

, Pipe sizes that are reduced as you go downstream.
Combustible piping used in multi-family buildings.
non-standard piping materials.

/.All of the following are problems you'll commonly find on house air fan blowers
EXCEPT - Answer-Installed backwards

Common Problems:
Dirty
Poorly Secured
Noisy or Vibrating

/.All of these are common closet lighting problems Except - Answer-the light is mounted
on a wall above the door.

Common Problems:
- The light is above a shelf
- The bare bulbs are used
- The bare bulbs are used with cages to provide mechanical protection.
-Installing the light above and toward one end of the shelf.

/.All switches must be greater than ______ horizontal feet from pool walls. - Answer-5
feet.

/.An electric heating system has - - Answer-an overcurrent protection device.

/.An inspector should report that a structure not attached to the home was present and
whether or not they inspected the structure. - Answer-True

/.An overcurrent protection device can be what? - Answer-A fuse or a breaker

/.As it relates to fuses, what is a safety concern? - Answer-A fuse that is too big.

/.At a range hood, excess noise or vibration or inadequate fan ________ or air flow
must be called out. - Answer-Speed

/.Attic ventilation that functions properly involves more than just install the required
_______ area - Answer-Ventilation area

/.Atypical defects than an home inspector should react is:
A. High water pressure
B. Medium water pressure
C. Designed water pressure
D. Low water pressure - Answer-Low water pressure

/.Bathroom exhaust fan vent tubes: - Answer-Must be vented through the roof.

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller kartelo. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $9.99. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

76658 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$9.99
  • (0)
  Add to cart