Residential Building Inspector Exam Prep Questions And Answers 20-Minute Study Blocks - Answer-Proven method for optimal concentration and learning productivity. /.Access to under-floor spaces - Answer-Minimum size and location of openings for under-floor access /.Anchoring of exterior fac...

[Show more]

Preview 2 out of 7  pages

  • September 5, 2024
  • 7
  • 2024/2025
  • Exam (elaborations)
  • Questions & answers
  • Residential Building Inspector
  • Residential Building Inspector
avatar-seller
kartelodoc
20-Minute Study Blocks - Answer-Proven method for optimal concentration and learning
productivity.

/.Access to under-floor spaces - Answer-Minimum size and location of openings for
under-floor access

/.Anchoring of exterior facilities - Answer-Methods for anchoring exterior facilities to
primary structures

/.Anchoring of wood sole plate - Answer-Wood sole plate at exterior walls on monolithic
slabs must be anchored with anchor bolts spaced a maximum of 6 feet on center.

/.Bathroom ceiling height - Answer-Bathrooms must have a minimum ceiling height of 7
feet at the center of the fixture clearance area.

/.Bracing determination for buildings - Answer-Method of determining bracing
requirements based on building layout

/.Cantilever back-span joists extension - Answer-Doubled cantilever back-span joists in
cold-formed steel framed floors must extend a minimum of 4 feet within the building.

/.Ceiling joist span for attics - Answer-For SS Douglas fir-larch 2X8 joists spaced 19.2
inches OC, the maximum span in uninhabitable attics without storage is 24-0.

/.Ceiling projections in basements - Answer-Ceilings in basements without habitable
spaces may project to within 6 feet 10 inches of the finished floor.

/.Certification Exam Details - Answer-Specifications for the ICC Residential Building
Inspector exam.

/.Cleanout openings in masonry chimneys - Answer-Requirement for cleanout openings
near the base of flues

/.Code arrangement - Answer-Organization of the code book for quick information
retrieval

/.Code book index - Answer-Alphabetical listing of topics for locating specific information

/.Code Book Structure - Answer-Understanding the organization and layout of the code
book.

, /.Code skimming - Answer-Quick reading to grasp the overall structure of the code book

/.Cold formed steel joist placement - Answer-Permitted location for cold formed steel
floor cantilevered joists

/.Construction basis for light frame buildings - Answer-Basis of requirements for light
frame building construction

/.Construction documents - Answer-Documents required for permit application,
prepared by a licensed architect or engineer as per jurisdiction statutes.

/.Construction Documents - Answer-Submission requirements for permit applications,
including site plans.

/.Continuous studs requirement - Answer-Specification for studs to resist loads
perpendicular to walls

/.Corrosion-resistant flashing definition - Answer-Definition of flashing integrated into
building walls

/.Egress door operability - Answer-Egress doors must be readily openable without the
use of a door knob, panic hardware bar, or special effort.

/.Emergency equipment repairs - Answer-In emergency equipment repairs, the permit
application must be submitted within the next working business day.

/.Emergency escape opening requirement - Answer-Emergency escape openings below
ground elevation must be provided with a window well.

/.Emergency escape openings operation - Answer-Criteria for operational emergency
escape openings

/.Excavation scope for footings - Answer-Inclusions in the scope of excavation for
footings

/.Exhaust air direction restriction - Answer-Prohibition on directing exhaust air to specific
locations

/.Exterior stairway illumination control - Answer-Location of control for exterior stairway
illumination

/.Fences permit exemption height - Answer-Fences under 4 feet high are exempt from
permit requirements.

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller kartelodoc. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $9.49. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

75632 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$9.49
  • (0)
  Add to cart