100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached
logo-home
EPA 608 Type 3 Exam Questions With Correct Answers $12.49   Add to cart

Exam (elaborations)

EPA 608 Type 3 Exam Questions With Correct Answers

 4 views  0 purchase
  • Course
  • EPA 608
  • Institution
  • EPA 608

EPA 608 Type 3 Exam Questions With Correct Answers On low pressure chillers, moisture typically enters the refrigerant system through - answerair leaks from areas with gaskets or fittings The maximum test pressure for leak testing a low pressure centrifugal is: - answer10 psig Leak test and re...

[Show more]

Preview 2 out of 10  pages

  • August 28, 2024
  • 10
  • 2024/2025
  • Exam (elaborations)
  • Questions & answers
  • EPA 608
  • EPA 608
avatar-seller
Thebright
©THEBRIGHT EXAM STUDY SOLUTIONS 8/27/2024 12:01 PM



EPA 608 Type 3 Exam Questions
With Correct Answers


On low pressure chillers, moisture typically enters the refrigerant system through - answer✔✔air
leaks from areas with gaskets or fittings

The maximum test pressure for leak testing a low pressure centrifugal is: - answer✔✔10 psig
Leak test and repair the chiller to reduce refrigerant loss from a pruge unit on CFC-11 chiller -
answer✔✔...

A hydrostatic tube test kit is used to: - answer✔✔determine if a tube leaks
Commercial and industrial process refrigeration systems must be repaired when the leak rate
exceeds ____ of the charge per year. - answer✔✔35%

Refrigerant recovery typically start with liquid recovery it is faster. - answer✔✔...

A rupture disc on a recovery vessel for a low pressure refrigerants relieves at: - answer✔✔15
psig
According to ASHRAE Guideline 3-1996, if the pressure in a system rises from 1 mm Hg to a
level above ____ during a standing vacuum test, the system should be checked for leaks. -
answer✔✔2.5 mm Hg

The primary water source for a recovery unit condensing coil is _____. - answer✔✔local
municipal water supply
When recharging a refrigeration system with R-11, what vaporpressure is necessary in the shells
before changing with liquid? - answer✔✔16.9" Hg vacuum

After recovering the liquid refrigerant you must: - answer✔✔recover the vapor refrigerant
According to the EPA there is approximately _____ refrigerant vapor left in an average 350 ton
R-11 chiller at 0 psig pressure once all the R-11 liquid has been removed. - answer✔✔100
pounds

, ©THEBRIGHT EXAM STUDY SOLUTIONS 8/27/2024 12:01 PM


Charging refrigerant liquid into a refrigeration system when it is under a 29 inch Hg vacuum can
cause the: - answer✔✔system water to freeze

A system does not have to be evacuated all the way to the required level when: - answer✔✔leaks
in the appliance make evacuation to the prescribed level unattainable
Which of the foloowing repairs would ALWAYS be considered "major" under EPA's -
answer✔✔replacement of evaporator coil
Under EPA's regulation's _______ is used to pressurize a low pressure chiller for the purpose of
opening the system for a non major repair? - answer✔✔warming the refrigerant
If you are using a recovery machine manufactored AFTER 11-15-93 you must evacuate an low
pressure appliance to _______ before making a major repair. - answer✔✔25 mm of Hg absolute

After reaching the required recovery vacuum on a chiller, you should - answer✔✔Wait for at
least a few minutes to see if the system pressure rises, indicating that there is till refrigerant in a
liquid form or in the oil

The pressure corresponding to 32 F for R-123 - answer✔✔20 inches of HG vacuum

When evacuating a system the use of too large a vacuum pump can cause? - answer✔✔trapped
water to freeze
Refrigerant-11 at a pressure of 17 inches HG vacuum has a saturation temperature of: -
answer✔✔35F
During the evacuation of a system containing large amounts of moisture you can prevent
freezing of this moisture by increasing the pressure with______gas - answer✔✔nitrogen
ASHRAE standard 15-1994 requires that each machinery room must activate an alarm and
mechanical ventilation beofre refrigerant concentrations exceed: - answer✔✔the threshold limit
valve and time weighted average
The typical design burst pressure for a rupture disk on a low pressure centrifugal air-conditioning
system is set at_______ - answer✔✔15 psi
Heat pumps that have been retrofitted from R22 to R407C should be leak checked with: -
answer✔✔pressurized nitrogen

When a new system has been assembled, the first thing to do is: - answer✔✔pressurize the
system with inert gas and leak check
EPA regulations require that leaking commercial or industrial process refrigeration equipment
must be repaired when the leak rate exceeds______ of the charge per year. - answer✔✔35%

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller Thebright. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $12.49. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

77988 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$12.49
  • (0)
  Add to cart