API 1169 Study test questions test RM#3 Questions & Answers| Passed
3 views 0 purchase
Course
API 1169
Institution
API 1169
According to Title 49, CFR 195, Subpart E: Carbon dioxide pipelines may use inert gas or carbon dioxide
as the test medium if the maximum hoop stress during the test does not exceed________________
percent of specified minimum yield strength and other conditions are met. - 80%
CFR 195.559 states...
API 1169 Study test questions test
RM#3 Questions & Answers| Passed
According to Title 49, CFR 195, Subpart E: Carbon dioxide pipelines may use inert gas or carbon dioxide
as the test medium if the maximum hoop stress during the test does not exceed________________
percent of specified minimum yield strength and other conditions are met. - ✔✔80%
CFR 195.559 states that coating material for external corrosion control (under CFR 195.557)
must__________________? - ✔✔Have enough strength to resist damage due to handling and soil
stress & have sufficient adhesion to the metal surface to prevent under film migration of moisture.
According to Title 29, CFR 1910, Subpart L: How often should portable fire extinguishers be inspected? -
✔✔Once per month
The application of the monogram can be applied only by the licensee at the_____________? -
✔✔licensed facility
,Pipe having a longitudinal or helical butt joint produced by at least two passes, one of which is on the
inside of the pipe. - ✔✔double submerged-arc-welded pipe
To meet the criteria of being a genuine workplace hazard, something should be able to be described in
_______________ or less words. - ✔✔5
Question The symbol for hydrogen sulfide is___________? - ✔✔H2S
True or false? An inspector directs the work flow of the contractor crew during excavation and
HDD activities. - ✔✔False (The inspector never directs the contractor)
A typical prevention device that is used to maintain safe working distances from overhead power lines
are known as______________? - ✔✔Goal posts
Cathodic protection can, in some cases, prevent__________? - ✔✔stress corrosion cracking
Higher concentrations of carbon and other alloying elements such as manganese, chromium, silicon,
molybdenum, vanadium, copper, and nickel tend to ____________hardness and ____________
weldability. - ✔✔increase/ decrease
All theses choices represent key factors for avoiding tool hazards except for: safety features in place, use
the right tool for the right job, type of power source, tool condition, proper PPE, correct use of the tool.
- ✔✔Type of power source.
impressed current is a type of ____________? - ✔✔cathodic protection
Per OSHA 29 CFR 1910.110, ventilation shall be considered adequate when the concentration of the gas
in a gas-air mixture does not exceed __________________percent of the lower flammable limit. -
✔✔25%
Glass fiber outerwrap is part of what type of coating? - ✔✔coal tar enamel
, A drainage ditch adjacent to roadways or field boundaries is known as a ______________? - ✔✔bar
ditch
The crew of welders responsible for positioning, aligning, and performing the initial welds on a
new construction pipeline project are called the_________________? - ✔✔pipe gang
How many feet would it be from station 58+00 to 68+00? - ✔✔1000'
A phenomenon whereby a pipeline segments fails at progressively lower test pressures
during subsequent pressure tests - ✔✔pressure reversal
This legislation covers hazardous substances, site contamination, and cleanup. -
✔✔Comprehensive Environmental Recovery, Compensation, and Liability Act
Large valves are typically located every __________________ miles along a pipeline route. - ✔✔5 to
20
True or false? During weld qualification, the fillet weld specimens can be broken inside the weld by
any convenient method. - ✔✔True
____________is the area where the ground disturbance occurs within 50 feet of the centerline of the
existing facility, or within the existing facility right-of-way (ROW) or other easement, whichever is
greater. - ✔✔Encroachment area
Small voids or pores, usually gas filled, in the weld material. - ✔✔porosity
According to Title 49, CFR 192, Subpart J: Except for fabricated units and short sections of pipe, for
which a post installation test is impractical, the hydro test must be conducted by maintaining the
pressure at or above the test pressure for at least__________ hours. - ✔✔8
The benefits of buying summaries with Stuvia:
Guaranteed quality through customer reviews
Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.
Quick and easy check-out
You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.
Focus on what matters
Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!
Frequently asked questions
What do I get when I buy this document?
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
Satisfaction guarantee: how does it work?
Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.
Who am I buying these notes from?
Stuvia is a marketplace, so you are not buying this document from us, but from seller KenAli. Stuvia facilitates payment to the seller.
Will I be stuck with a subscription?
No, you only buy these notes for $12.49. You're not tied to anything after your purchase.