This space generally houses equipment that serves an entire building,
campus or customer. - Answer️️ -Equipment Room (ER)
A _________ is an enclosed architectural space for housing
telecommunications equipment, cable terminations, and cross-connec...
This space generally houses equipment that serves an entire building,
campus or customer. - Answer✔️✔️-Equipment Room (ER)
A _________ is an enclosed architectural space for housing
telecommunications equipment, cable terminations, and cross-connect
cabling. - Answer✔️✔️-Telecommunications Room (TR)
The telecommunications service entrance to the building is called the _____
- Answer✔️✔️-Entrance Facility (EF)
A _____ typically serves one floor of a building or a portion of a floor -
Answer✔️✔️-Telecommunications Room (TR)
The ______ serves as a point of termination for horizontal and backbone
cables on compatible connecting hardware. - Answer✔️✔️-
Telecommunications Room (TR)
The ______ provides space for an EF. - Answer✔️✔️-Equipment Room (ER)
The color field for the "Network" termination field is - Answer✔️✔️-Green
The color field for the "Miscellaneous" termination field is - Answer✔️✔️-
Yellow
The color field for the "Demarcation Point" termination field is -
Answer✔️✔️-Orange
The color field for the "Common Equipment" termination field is -
Answer✔️✔️-Purple
The color field for the "Reserved" termination field is - Answer✔️✔️-Red
The color field for the "Inter building backbone cable" termination field is -
Answer✔️✔️-Brown
The connection between the Horizontal cable and the backbone cable is
called the _______ - Answer✔️✔️-HC (FD)
A TE can serve a maximum of _______ - Answer✔️✔️-3600 feet squared
The 2 different "types" of backbone cabling are _______ and ______ -
Answer✔️✔️-Intrabuilding
Interbuilding
_______ cabling is the portion of the telecommunications cabling system
that connects the work areas to the other telecommunications spaces -
Answer✔️✔️-Horizontal
A ________ connects a cable field to an active component. - Answer✔️✔️-
Interconnection
A ______ connects 1st level backbone to 2nd level backbone - Answer✔️✔️-
Intermediate cross-connect
The _____ is housed in the ER ad connects the entrance cabling, backbone
cabling and equipment cabling - Answer✔️✔️-Main Cross-connect (MC) or
Campus Distributor (CD)
Page 2 of 5
The benefits of buying summaries with Stuvia:
Guaranteed quality through customer reviews
Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.
Quick and easy check-out
You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.
Focus on what matters
Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!
Frequently asked questions
What do I get when I buy this document?
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
Satisfaction guarantee: how does it work?
Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.
Who am I buying these notes from?
Stuvia is a marketplace, so you are not buying this document from us, but from seller SophiaBennett. Stuvia facilitates payment to the seller.
Will I be stuck with a subscription?
No, you only buy these notes for $9.99. You're not tied to anything after your purchase.