100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached
logo-home
P-99 / Low PSI Oil Burner Operator Questions With 100%Verified Answers A+GRADED $8.99   Add to cart

Exam (elaborations)

P-99 / Low PSI Oil Burner Operator Questions With 100%Verified Answers A+GRADED

 8 views  1 purchase
  • Course
  • P-99 / Low PSI Oil Burner
  • Institution
  • P-99 / Low PSI Oil Burner

P-99 / Low PSI Oil Burner Operator Questions With 100%Verified Answers A+GRADED All heating, combustion, and cooking equipment shall be provided with insulation or the building construction shall be fire protected, so that during operation the surface of combustible construction materials will n...

[Show more]

Preview 2 out of 9  pages

  • August 26, 2024
  • 9
  • 2024/2025
  • Exam (elaborations)
  • Questions & answers
  • P-99 / Low PSI Oil Burner
  • P-99 / Low PSI Oil Burner
avatar-seller
agradesolutions
P-99 / Low PSI Oil Burner Operator
Questions With 100%Verified Answers
A+GRADED
All heating, combustion, and cooking equipment shall be provided with insulation or the
building construction shall be fire protected, so that during operation the surface of
combustible construction materials will not be raised to a temperature higher than ____.
- correct answer...✔✔

Acceptance tests: Boilers shall not be placed in operation upon completion of
construction until they have been ____ and an equipment use permit has been issued
by the commissioner. - correct answer...✔✔Inspected and tested.

Periodic boiler inspections: All boilers shall be inspected at least ____ including
chimney connections. - correct answer...✔✔Once a year.

Owner's annual statement: The owner of each boiler that is subject to periodic
inspections shall file an annual ____ with the commissioner, specifying the location of
each boiler and arrangement for inspection. - correct answer...✔✔Written statement.

What three things must be tested for any fuel burning and storage installation before the
system can be operated? - correct answer...✔✔(1) Tightness of liquid fuel piping.

(2) Tightness of fuel oil storage tanks.

(3) Tightness of gas distribution piping.

What are instruction cards for oil burning systems? - correct answer...✔✔Cards giving
complete instructions for care and operation that are permanently located near the
equipment.

Every oil burning installation that is not fully automatic or requires preheating shall be
operated by, or under, the direct supervision of a person holding a ____ issued by the
fire commissioner. - correct answer...✔✔COF

After any fuel burning equipment repair for which a licensed operator is required, such
operator shall also check the repairs and be ____ while the equipment is started. -
correct answer...✔✔Present.

What is abatement of air contaminants? - correct answer...✔✔Compliance with the air
pollution control code.




AGRADESOLUTIONS

, What are the 3 equipment classifications and their temperatures for the products of
combustion at the point of leaving the equipment? - correct answer...✔✔(1) Low Temp:
600° F or less.

(2) Medium Temp: 600° - 1000° F.

(3) High Temp: 1000° or greater.

Ventilation shall be capable of providing at least ____ CFM of air for each gallon of oil
per hour required to fire the equipment to gross output. - correct answer...✔✔36

What is fuel-oil? - correct answer...✔✔Hydrocarbon oils with a flashpoint not lower than
F.

The use of crankcase refuse oil as fuel-oil is ____. - correct answer...✔✔Prohibited.

Overflow pipes shall not be smaller in size than the ____ pipe. - correct answer...✔✔
Supply.

Oil is heated in storage tanks by coils using which three possible methods? - correct
answer...✔✔(1) Low pressure hot water.

(2) Steam

(3) Electric heaters.

A remote control for oil burner is provided to stop what? - correct answer...✔✔The flow
of oil to any burner.

What are the four safety controls that shall be installed with each automatic burner? -
correct answer...✔✔(1) Oil temperature.

(2) Ignition.

(3) Stack or combustion.

(4) High temperature or pressure.

No oil burner shall be installed unless it is connected to a ____. - correct answer...✔✔
Chimney/smoke stack.

What provides the supply of oil for combustion in the oil burner? - correct answer...✔✔
Storage tank.




AGRADESOLUTIONS

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller agradesolutions. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $8.99. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

67096 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$8.99  1x  sold
  • (0)
  Add to cart