100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached
logo-home
UST QUESTIONS AND ANSWERS TO STUDY FOR 2024 FINAL EXAM/100% VERIFIED A+ $7.99   Add to cart

Exam (elaborations)

UST QUESTIONS AND ANSWERS TO STUDY FOR 2024 FINAL EXAM/100% VERIFIED A+

 2 views  0 purchase
  • Course
  • Institution

UST QUESTIONS AND ANSWERS TO STUDY FOR 2024 FINAL EXAM/100% VERIFIED A+The regulations to enforce compliance of underground storage tank systems in the state are found in? a.) Code of Federal Regulations, 40 CFR Part 281 b.) California Code of Regulations, Title 23, Chapter 16 c.) Code of Fe...

[Show more]

Preview 4 out of 64  pages

  • August 23, 2024
  • 64
  • 2024/2025
  • Exam (elaborations)
  • Questions & answers
avatar-seller
Created by: A Solution


UST QUESTIONS AND ANSWERS TO STUDY FOR 2024 FINAL
EXAM/100% VERIFIED A+
The regulations to enforce compliance of underground storage tank systems in the state are found
in?




a.) Code of Federal Regulations, 40 CFR Part 281
b.) California Code of Regulations, Title 23, Chapter 16
c.) Code of Federal Regulations, 40 CFR Part 280
d.) California Code of Regulations, Title 23, Chapter 17 - ANSWER----b.) California Code of
Regulations; Title 23, Chapter 16




By definition an "underground storage tank system" includes




a.) The tank, all connected piping and dispensers
b.) The tank, all connected piping, ancillary equipment and containment system
c.) Only the tank
d.) Only tanks totally beneath the surface of the ground - ANSWER----b.) The tank, all
connected piping, ancillary equipment and containment system




(H&SC, Sec 25281(z))


Under-dispenser containment was required for all UST systems by .
a.) December 31, 2003
b.) July 1, 1987
c.) January 1, 1984
d.) January 1, 2000 - ANSWER----a.) December 31, 2003



A+ Page 1

,Created by: A Solution



CCR Title 23, Sec 2636(g)(C)




According to California Law, UST systems installed after July 1, 2003, require a one-time ELD
test to ensure that the tank is product tight...




a.) If the tank is located within one (1) mile of a public drinking water well b.) If the tank is
located within 1000 feet of a public drinking water well c.) Unless the tank is equipped with
secondary containment
d.) In all cases - ANSWER----For ALL tanks before use (H&SC 25290.2 (I))
d.) In all cases




H&SC, Sec 25290.2(i)




The written report submitted to the local agency after an unauthorized release is required to
include the following except:




a.) Description of actions taken to stop the release
b.) Cause of the release
c.) Method of disposal of released product
d.) Date on which the release was discovered - ANSWER----b.) Cause of the release




CCR Title 23, Sec 2652(c)



A+ Page 2

,Created by: A Solution



An unauthorized release which does not escape from secondary containment only requires a
record on the operator's monitoring reports provided:




A. It did not increase the hazard of fire
B. It did not cause any deterioration of the secondary containment
C. It was cleaned up within 8 hours of detection
D. All of the above - ANSWER----D. All of the above


H&SC, Sec 25294




The annual monitoring certification may be performed by:


A. A person possessing the appropriate contractors licenses
B. An individual trained and certified by the manufacturer of the monitoring equipment
C. A designated UST operator
D. A person who meets the requirements of both a and b - ANSWER----D. A person who
meets the requirements of both a and b




CCR Title 23, Sec 2715(i)




A+ Page 3

, Created by: A Solution


The following is true of secondary containment testing, EXCEPT:


a.) Must be tested every 24 months
b.) Must be tested every 36 months
c.) Results must be submitted to the local agency within 30 days of testing
d.) Local agency must be notified 48 hours prior to testing - ANSWER----a.) Must be tested
every 24 months


CCR Title 23, Sec 2637(a)




Records of cathodic protection system maintenance must be kept on file for .




a.) 10 years
b.) 1.5 years
c.) 3 years
d.) 6.5 years - ANSWER----d.) 6.5 years




CCR Title 23, Sec 2712(b)




Impressed current cathodic protection systems shall be inspected no less than every to
ensure that they are in proper working order:


a.) 60 days
b.) 90 days
c.) 30 days
d.) 120 days - ANSWER----a.) 60 days



A+ Page 4

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller ASolution. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $7.99. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

76710 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$7.99
  • (0)
  Add to cart