in areas where future excavation is anticipated, it may be advisable to place
the cable at a greater depth. For example, if road grading that will remove
610 mm (24 in) of dirt is planned in a particular area, it would be wiser to
initially place the cable at 1.2 m (4 ft) versus the standard
610 mm (24 in). - CORRECT-ANSWERSTrue
OSP designers need to give special consideration to telecommunications
services at ______ - CORRECT-ANSWERSmarinas
OSP designers need to give special consideration to telecommunications
services at marinas because of the following unique conditions: - CORRECT-
ANSWERS• Changing water levels
• High moisture and humidity
• Severe weather (e.g., winds, waves, sun)
• Potential for deterioration of the distribution cable ( cable damage )
• Salt (corrosive environment)
• Transience of boat owners ( temporary )
• Difficulty in establishing a dependable and approved electrical grounding
point
The space reserved for a boat adjacent to a dock is _______ - CORRECT-
ANSWERSBoat slip
A portion of a dock that is publicly accessible to all marina users is call
________ - CORRECT-ANSWERSCommon element
placing all of the conduits during the initial conduit system installation is
desirable,
if not mandatory.
*True
*False - CORRECT-ANSWERSTrue
A portion of a dock that is accessible only to those boat
slips that it serves on either side is call ________ - CORRECT-ANSWERSLimited
common element (LCE)
A boat slip that is owned or subleased is ________ - CORRECT-
ANSWERSCondominium slip
,To accommodate the movement of a floating dock to and from a shoreline,
the following arrangements should be used: - CORRECT-ANSWERS• Hose-
reeling cable on a floating section
• A point of connection at both ends of a dock section to ease adding or
removing sections
of cable
• Jack and plug arrangements for smaller installations that need only a few
service cables
• Cables placed in a festoon arrangement, similar to the festooned cables
placed on
bleachers that are retracted and expanded
It is known in advance that all or most of the boat slips require
telecommunications services - CORRECT-ANSWERSPrecable each boat slip
during construction of the dock. For security, each run should be terminated
in the patch panel cross-connect at the dock master or marina office.
Fewer than 10 boat slips are cabled - CORRECT-ANSWERSRun one- or two-
pair cables from the boat slips to a distribution terminal on the closest point
of land.
If 10 or more boat slips are cabled - CORRECT-ANSWERSPlace distribution
cable onto the dock and terminate in a suitable cabinet or enclosure. Run
service drop to each boat slip.
All cable splices should be mechanically protected from the harsh
environment using: - CORRECT-ANSWERS• Conduit.
• Cable trays.
• Weatherproof enclosures.
• Other structures suited for harsh, outdoor conditions.
______ cable on docks should be used. - CORRECT-ANSWERSWater-blocked
in marinas the type and size of conduit can be selected following these
guidelines: - CORRECT-ANSWERS• Use rigid nonmetallic conduit wherever
possible.
• Join the sections of rigid conduit with flexible duct where movement of a
dock is probable.
• Use minimum 21 mm (3/4 trade size) conduits for service cables to each
slip.
a common telecommunications conduit within a prefabricated dock section
might be the only available cabling medium: - CORRECT-ANSWERS• In areas
where direct local exchange service and public telephone service are
provided by
,different companies.
• Where CATV is requested.
When an individual boat slip is owned and subleased as a regular
condominium, only the two bordering boat slip owners can legally use a
finger slip, a limited common element.
True
False - CORRECT-ANSWERSTrue
It is not always necessary to build new pathways for cable placement
*True
*False - CORRECT-ANSWERSTrue
The length of a cable loop from the switch to a customer depends on three
factors - CORRECT-ANSWERS• Resistance of the cable in ohms
• Signaling limits of the telephone and the terminating device switch in ohms
• Pair loading
Outside Plant (OSP) - CORRECT-ANSWERSTelecommunications OSP cabling
began with the placement of the first telegraph system,
Codes - CORRECT-ANSWERSrules specified by governmental entities
Installation manuals are examples of - CORRECT-ANSWERSMethodology
Support structures: - CORRECT-ANSWERS- MHs).
- (HHs).
- Poles, support strands, and guying information.
The basic types of OSP pathways and spaces are: - CORRECT-ANSWERS•
Underground.
• Direct-buried.
• Aerial.
advantage to use optical fiber in backbones campus applications: -
CORRECT-ANSWERS• Increased distance.
• Higher bandwidth applications.
, • All-dielectric cable.
• Less susceptibility to EMI and lightning.
• No crosstalk.
• No grounding (earthing) requirement for all-dielectric cable.
Optical Fiber Connectors: - CORRECT-ANSWERS• LC
• SC
• ST
How to calculate passive cable system attenuation - CORRECT-
ANSWERSTotal optical fiber loss
+ Total connector loss
+ Total splice loss
Calculate link loss budget - CORRECT-ANSWERSSystem gain - Power
penalties
Splice loss values - CORRECT-ANSWERSMM SM
SP type Avr. max. Avr. max.
Fusion 0.05 0.3 0.05 0.3
Mecha 0.10 0.3 0.10 0.3
Ribbon fiber - CORRECT-ANSWERSdesigns can be single tube or
multitube ,the fiber is bound in a flat array
Tight-buffered fibers - CORRECT-ANSWERShave a 900 μm coating applied
directly to the optical fiber.
A transition point shall be required for unlisted OSP cable when the
termination
point is greater than _________ from the point of entrance and the cable
cannot
be installed in a properly rated conduit. - CORRECT-ANSWERS15 m (50 ft)
NEMA - CORRECT-ANSWERSNational Electrical Manufacturers Association
Most blown fiber systems publish maximum blowing distances of ____________
without
employing advanced blowing techniques. - CORRECT-ANSWERS1 km (3281
ft)
ITU G.652D - CORRECT-ANSWERSSinglemode, low water, nondispersion-
shifted fiber [NDSF]
The benefits of buying summaries with Stuvia:
Guaranteed quality through customer reviews
Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.
Quick and easy check-out
You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.
Focus on what matters
Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!
Frequently asked questions
What do I get when I buy this document?
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
Satisfaction guarantee: how does it work?
Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.
Who am I buying these notes from?
Stuvia is a marketplace, so you are not buying this document from us, but from seller Elitaa. Stuvia facilitates payment to the seller.
Will I be stuck with a subscription?
No, you only buy these notes for $19.99. You're not tied to anything after your purchase.