100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached
logo-home
MOSBY CT REGISTRY REVIEW QUESTIONS AND ANSWERS WITH SOLUTIONS 2024 $16.49   Add to cart

Exam (elaborations)

MOSBY CT REGISTRY REVIEW QUESTIONS AND ANSWERS WITH SOLUTIONS 2024

 4 views  0 purchase
  • Course
  • CT REGISTRY
  • Institution
  • CT REGISTRY

MOSBY CT REGISTRY REVIEW QUESTIONS AND ANSWERS WITH SOLUTIONS 2024

Preview 4 out of 66  pages

  • August 18, 2024
  • 66
  • 2024/2025
  • Exam (elaborations)
  • Questions & answers
  • CT REGISTRY
  • CT REGISTRY
avatar-seller
Performance
MOSBY CT REGISTRY REVIEW
QUESTIONS AND ANSWERS WITH
SOLUTIONS 2024
What is the smallest component of a digital image - ANSWER pixel



How many CT numbers are assigned to each pixel in the image matrix? - ANSWER One



In a CT image, the CT number - ANSWER Of a material is dependent on its linear attenuation coefficient



Each two-dimensional square of data that make up the CT image is called a - ANSWER pixel



What is an element of the digital image - ANSWER pixel



Which of the following influences the spatial resolution in cardiac CT imaging - ANSWER *detector size

*reconstruction interval

*pitch



As patient motion increases spatial resolution decreases - ANSWER TRUE



Which is an advantage of using a small focal spot - ANSWER increased spatial resolution



Increasing the CT image matrix from 256x256 to 512x512 will likely improve? - ANSWER High-contrast
spatial resolution



The practical limiting spatial resolution of a CT scanner is 3.6 lp/cm. What size object does this
correspond to? - ANSWER 1.4 mm



Use of a bone filter, as opposed to a soft tissue filter, to reconstruct CT images would likely improve? -
ANSWER Spatial resolution

,The spatial resolution of a typical CT scanner is on the order of? - ANSWER 1 mm



A 512 x 512 matrix CT image over a 30-cm field of view could show a spatial resolution of no better than
? lp/cm? - ANSWER 8.5



When comparing a 512x512 matrix to a 1024x1024 matrix, the 1024x1024 matrix? - ANSWER Contains
four times as many pixels: 1024 x 1024 =1048576 then 512 x 512= 262144...then divide 1048576
/262144 = 4



High contrast spatial resolution and low contrast resolution are typically measured baseline and ?
thereafter - ANSWER Biannually



To improve the high contrast spatial resolution of a CT study, one would increase _____ while keeping all
other factors the same. - ANSWER Matrix size (128x128 to 512x512)



A radiologist wants to improve the high-contrast spatial resolution of anatomy which he/she is examining
by CT. The change which would best lead to this improvement is - ANSWER Increase the matrix size



To improve the high-contrast spatial resolution of a CT study, one could increase ? while keeping all other
factors the same? - ANSWER Matrix size



A voxel contains 25% air, 50% water and 25% bone. The CT number for this voxel would be expected to
be _____ HU? - ANSWER 0



How many pixels are contained in a 1,024 matrix image? - ANSWER D. 1,048,576



MATH 1024 X1024



It is located in a matrix and is a two dimensional representation of a voxel - ANSWER pixel

,When CT numbers are calculated for voxels (volume elements) of tissue what is assigned the calculated
number and a subsequent shade of gray - ANSWER pixel



What is defined as a picture element or the smallest component of the digital image - ANSWER pixel



A CT scan produces a 512x512 matrix transverse image of a 30 cm diameter FOV. Each pixel is
approximately _____ mm on a side. - ANSWER 0.6 equation: 30cm/512= .058cm convert to mm and its
.58 which is approximately 0.6



The ability of a system to define small objects distinctly is referred to as which of the following? -
ANSWER spatial resolution



Which of the following terms is/are commonly used to describe a CT scanner's ability to differentiate
objects with similar linear attenuation coeffiecents - ANSWER *spatial resolution

*sensitivity



Which of the following factors have an affect on contrast resolution - ANSWER *patient size

*slice thickness

*pixel size

*mAs/dose



As mAs/dose increases contrast resolution decreases - ANSWER FALSE



As mAs/dose increases contrast resolution INCREASES - ANSWER TRUE



The ability of a CT scanner to accurately image objects with similar densities is termed - ANSWER
*contrast resolution

*sensitivity



Which of the following has a direct relationship on increasing contrast resolution - ANSWER *mAs/dose
increase

, *Slice thickness



For a particular CT scanner's beam quality, the linear attenuation coefficient for water is 0.20 cm-1 and
for a certain tumor is 0.21 cm-1. What is the CT number of the tumor? - ANSWER 50. Equation (.21-
.20/.21) × 1000= 50



A CT scanner with poor contrast resolution or low sensitivity has difficulty separating - ANSWER tissues
whose linear attenuation coefficients are nearly equal



What is the basic physical quantity being measured by a CT system - ANSWER Linear attenuation
coefficient



Assume the linear attenuation coefficient is 0.20 cm-1 for water and 0.40 cm-1 for tissue within a given
voxel. What is the CT number in Hounsfield units for the pixel representing this voxel? - ANSWER
+1,000....Equation { (.4-.2) /.2} x 1000



What fraction of monoenergetic x-rays will be absorbed by a 20-cm thick material having a linear
attenuation coefficient of 0.05 cm-1? - ANSWER 0.63



The contrast resolution of CT is approximately ? % - ANSWER 0.3 to 0.6



This term describes the ability CT scanner to differentiate objects with MINIMAL differences in
attenuation coefficients - ANSWER contrast resolution



What is the term for resolution of a CT scanner referred to as the system's ability to differentiate objects
with SIMILAR densities. - ANSWER contrast resolution



In order to pass ACR CT accreditation, the CT scanner's adult head protocol must be within - ANSWER 1.0



The QC test for the average CT number for water should be done - ANSWER Daily

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller Performance. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $16.49. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

82215 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$16.49
  • (0)
  Add to cart