100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached
logo-home
Fire pump Questions And Answers With Verified Updates $7.99   Add to cart

Exam (elaborations)

Fire pump Questions And Answers With Verified Updates

 8 views  0 purchase
  • Course
  • Fire pump
  • Institution
  • Fire Pump

Fire pump buildings or rooms enclosing diesel engine pump drivers and day tanks shall be protected with an automatic sprinkler system installed in accordance with NFPA 13, Standard for the installation of sprinkler systems. - True Where maximum flow available from the water supply cannot provide...

[Show more]

Preview 2 out of 5  pages

  • August 18, 2024
  • 5
  • 2024/2025
  • Exam (elaborations)
  • Questions & answers
  • Fire pump
  • Fire pump
avatar-seller
ACADEMICMATERIALS
Fire pump
Fire pump buildings or rooms enclosing diesel engine pump drivers and day tanks shall be protected with
an automatic sprinkler system installed in accordance with NFPA 13, Standard for the installation of
sprinkler systems. - True



Where maximum flow available from the water supply cannot provide a flow of 150 percent of the rated
flow of the pump , but the water supply can provide the greater of _____ percent of rated flow or the
maximum flow demand of the fire protection systems, the water supply shall be deemed to be
adequate. in this case, the maximum flow shall be considered the highest flow that the water supply
cannot achieve. - 100



pumps other than those specified in this standard and having different design features shall be permitted
to be installed where such pumps are listed by a testing laboratory. these pumps shall be limited to
capacities of less than _____ gpm. - 500



Any source of water that is adequate in quality, quantity, and pressure shall be permitted to provide the
supply for a fire pump. - true



acceptable drivers for pumps at a single installation shall be electric motors, diesel engines,_______, or a
combination thereof. - steam turbines



A pressure gauge having a dial not less than_______ in diameter shall be connected near the discharge
casting with a nominal .25 in. gauge valve. - 3.5"



The dial on the gauge on the discharge side of the pump shall indicate pressure to at least twice the
rated working pressure of the pump but not less than _____ psi. - 200



Where the minimum pump suction pressure is below 20 psi under any flow condition, the suction gauge
shall be a __________ pressure and vacuum gauge. - compound

, unless the requirements if 4.11.1.7 are met, each pump shall have an automatic relief valve listed for the
fire pump service installed and set below the shutoff pressure at minimum expected suction pressure. I.
4.11.1.7 which pumps do not require automatic relief valve. - Engine Driven



The automatic relief valve shall have a nominal size of .75 in. for pumps with a rated capacity not
exceeding 2500 gpm and have a nominal size of ______ for pumps with a rated capacity of 3000 gpm to
5000 gpm. - 1"



Fire pump units that are outdoors shall be located at least ______ away from any buildings and other fire
exposures exposing the building. - 50'



Where the suction supply is of sufficient pressure to be of material value without the pump, the pump
shall be installed with a ______. - bypass



A listed ______ gate valve shall be installed in the suction pipe. No other kind of valves shall be installed
in the suction piping within 50' of the fire pump. - OS&Y



Where the suction pipe and pump suction flange are not of the same size, they shall be connected with
an _______ tapered reducer or increase installed in such a way as to avoid air pockets. - eccentric



A listed ______ or backflow preventer shall be installed in the pump discharge assembly. - check
valve



Where pumps are installed in a series, a __________ valve shall not be installed between pumps. -
Butterfly



When a low suction throttling valve is used, it shall be installed according to manufacturers
reccomendations in the piping between the pump and the discharge _________. - check valve



in fire pump assemblies a clearance of not less than _______ shall be provided around pipes that pass
through walls or floors. - 1"

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller ACADEMICMATERIALS. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $7.99. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

79223 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$7.99
  • (0)
  Add to cart