What is: Design wind pressure? Correct Answer-Design wind pressure: Minimum design value for the equivalent static pressure on the exterior surfaces resulting from critical wind velocity (equal to a reference wind wind pressure measured at 33', 10m). The # is modified by a bunch of coefficients t...

[Show more]

Preview 4 out of 36  pages

  • August 17, 2024
  • 36
  • 2024/2025
  • Exam (elaborations)
  • Questions & answers
  • Exac
  • Exac
avatar-seller
cracker
ExAC - Section 3 - Final Project Questions with
Correct Answers
What is: Design wind pressure? Correct Answer-Design wind pressure:
Minimum design value for the equivalent static pressure on the exterior
surfaces resulting from critical wind velocity (equal to a reference wind
wind pressure measured at 33', 10m). The # is modified by a bunch of
coefficients to account for: exposure conditions, building height, wind
gusts, geometry/orientation.


Why are horizontal forces more critical than vertical ones in seismic
design? Correct Answer-Because structures usually have considerable
reserve for dealing with additional vertical loads.


Define Base Shear. Correct Answer-Base shear:
Minimum design value for the total lateral seismic force (assumed to act
in any horizontal direction)


Define the following: Collinear Forces, Concurrent Forces,
Nonconcurrent Forces. Correct Answer-Collinear Forces:
Occur along straight line. Vector sum= sum of magnitude of forces
acting along same line of action.


Concurrent Forces:
Lines of action intersecting at common point. Vector sum=equivalent to,
and produces same effect on rigid body as the application of the vectors
of the several forces.

,Nonconcurrent Forces:
Lines of action that do not intersect at common point. Vector
sum=single force that would cause the same translation and rotation of a
body as the set of original forces.


What is a moment (structural forces)? Correct Answer-Moment:
The tendency of a force to produce rotation of a body about a point or
line


What is a Couple (structural forces)? Correct Answer-Couple:
Force system of 2 equal parallel forces acting in opposite directions
tending to produce rotation but not translation


What are beams designed to do? Correct Answer-Designed to carry and
transfer transverse loads across to supporting elements.


Define Deflection Correct Answer-Deflection:
perp distance a spanning member deviates from true course under
transverse loading


What is the difference between a simple beam and a Fixed-End Beam?
Correct Answer-Simple Beam:
Rests on supports at both ends - no moment resistance (ends free to
rotate)

,Fixed-end beam:
Both ends fixed against translation and rotation (reduced max deflection,
transferred bending stresses, increased rigidity)


Distinguish between the following three frame types:
-Fixed Frame
-Hinged Frame
-Three Hinged Frame Correct Answer-Fixed Frame
rigid frame connected to its supports with fixed joints (more resistant to
deflection than hinged from but also more sensitive to settlements and
thermal expansion/contraction)


Hinged Frame -
Rigid frame connected to its joints with pinned connections (pinned
connections prevent high bending stresses by allowing rotation)


Three-hinged Frame - structural assembly of 2 rigid sections connected
to each other and to its supports with pin joints (more sensitive to
deflection than fixed or hinged, 3-hinged system is least affected by
support settlements and thermal stresses - can also be analyzed as a
statically determinate structure


Name 1 kind of beam for each wood, steel, and concrete, that can span
>60' (18m). Correct Answer-Wood:
Laminated Beams (Timber)

, Trusses (Timber)


Steel:
OWSJ


Concrete:
Precast Tees


List three basic mechanisms for resisting lateral loads. Correct Answer-
Rigid Frame
steel or reinforced concrete with rigid joints


Shear Wall
wood/concrete/masonry - resist changes of shape and transfer cert loads
to ground foundation


Braced Frame - timber or steel
Knee brace
K-brace
Cross-brace


What is the least effective way to achieve lateral stability? Correct
Answer-Rigid frame (only appropriate in low-mid rise buildings)

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller cracker. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $14.49. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

75391 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$14.49
  • (0)
  Add to cart