100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached
logo-home
IEC FINAL YEAR EXAM GUIDE NEWEST VERSION EXPECTED QUESTION AND CORRECT ANSWER FROM VERIFIED SOURCES RATED A GRADE. $19.99   Add to cart

Exam (elaborations)

IEC FINAL YEAR EXAM GUIDE NEWEST VERSION EXPECTED QUESTION AND CORRECT ANSWER FROM VERIFIED SOURCES RATED A GRADE.

 8 views  0 purchase
  • Course
  • IEC YEAR
  • Institution
  • IEC YEAR

IEC FINAL YEAR EXAM GUIDE NEWEST VERSION EXPECTED QUESTION AND CORRECT ANSWER FROM VERIFIED SOURCES RATED A GRADE.

Preview 4 out of 53  pages

  • August 17, 2024
  • 53
  • 2024/2025
  • Exam (elaborations)
  • Questions & answers
  • IEC YEAR
  • IEC YEAR
avatar-seller
teachme2expert
IEC FINAL YEAR EXAM GUIDE NEWEST VERSION 2024-2025
EXPECTED QUESTION AND CORRECT ANSWER FROM VERIFIED
SOURCES RATED A GRADE.


What type of switch would you use to control a lighting load from one
location only? ✔✔ANSWER✔✔Single pole


SPST is an abbreviation for ___. ✔✔ANSWER✔✔Single Pole-Single
Throw


The neutral conductor of a 120-volt circuit is referred to as the ___
conductor in the NEC®. ✔✔ANSWER✔✔grounded


The "hot" conductor of a circuit is referred to as the ___ conductor in
the NEC®. ✔✔ANSWER✔✔ungrounded


When installed as the neutral for a 120-volt circuit, the neutral is
considered to be a current-carrying conductor. ✔✔ANSWER✔✔True


Which of the following is an example of a "device?"
✔✔ANSWER✔✔GFCI receptacle


The color of the insulation of a neutral conductor that is 8 AWG shall be
___.

,I. white II. bare III. gray ✔✔ANSWER✔✔I or III only


An insulated grounded conductor of 6 AWG or smaller shall be
identified by a continuous white or gray outer finish or by ___
continuous white stripes on other than green insulation along its entire
length. ✔✔ANSWER✔✔3


What conductor in a circuit cannot be marked with a color of white or
gray?
I. grounded II. equipment grounding III. ungrounded ✔✔ANSWER✔✔II
& III only


Where installed in conduit, which of the following wire colors are
permitted for "hots," travelers, and switch legs of a circuit?
I. black, red, and blue
II. brown, orange, and yellow
III. pink, black, and blue ✔✔ANSWER✔✔I or II or III


What conductor in a circuit can be marked with a green color?
I. grounded II. equipment grounding III. ungrounded ✔✔ANSWER✔✔II
only


A luminaire has one blue wire and one white wire for field connection.
When using cable (NM, AC, or MC for example), the wire connected to

,the blue wire from the luminaire ___. ✔✔ANSWER✔✔must have
colored insulation (not green or white or gray)


The Code section that addresses sensor (automatic) control of lighting
in a restaurant bathroom is ___. Select N/A (not applicable) if there is
not a Code reference for this. ✔✔ANSWER✔✔N/A


For stairway lighting, a typical installation is to install a 3-way switching
system. For a commercial building, ___ for stairway lighting control.
✔✔ANSWER✔✔there are no NEC® requirements


Both lamps are to be controlled from the switch. Which of the
connection diagrams shown in Figure 112.511 is wired to operate
correctly and does not violate 200.7 in the NEC®? Type AC 12-2 and 12-
3 cables are used between the outlet boxes. Future wall access is
available as required in NEC® 404.2(C)(2). ✔✔ANSWER✔✔IV only


Refer to Figure 112.512. The lamp on the right is to be ON constantly (as
a night light) and the lamp on the left is to be controlled from the
switch. Which of the connection diagrams is wired to operate correctly
and does not violate 200.7 in the NEC®? Type AC 12-2 and 12-3 cables
are used between the outlet boxes. Future wall access is available as
required in NEC® 404.2(C)(2). ✔✔ANSWER✔✔none of these

, The lamp shown in Figure 122.514 is to be controlled from either
switch. Which of the following statements is true for Connection
Diagram B? No wall access is available for future cable installation.
I. It is wired to operate correctly.
II. The markings on the white conductor do not violate 200.7(C)(1) in
the NEC®.
III. This installation meets the requirements of NEC® 404.2(C).
✔✔ANSWER✔✔Not I & II only


Which of the connection diagrams shown below is wired to operate
correctly so that the lamp can be controlled from any switch and the
markings on the white conductors do not violate NEC® 200.7? Future
wall access is available as required in NEC® 404.2(C)(2).
✔✔ANSWER✔✔B , 2nd option pic


Which of these is the symbol used for a 4-way switch?
✔✔ANSWER✔✔c.$4


Lighted handle toggle switches utilize a neon lamp that is illuminated
when the switch is in the ___ position. ✔✔ANSWER✔✔b.OFF


The ungrounded conductor is often called the ___. ✔✔ANSWER✔✔hot


Drawing ___ in Figure 112.415 is a framed locking (not key-lock) type
switch. ✔✔ANSWER✔✔Not D.VI or E.None of these

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller teachme2expert. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $19.99. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

78834 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$19.99
  • (0)
  Add to cart