100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached
logo-home
ASE ELECTRICAL EXAM - GENERAL ELECTRICAL/ELECTRONIC SYSTEM DIAGNOSIS QUESTIONS AND ANSWERS WITH SOLUTIONS 2024 $14.49   Add to cart

Exam (elaborations)

ASE ELECTRICAL EXAM - GENERAL ELECTRICAL/ELECTRONIC SYSTEM DIAGNOSIS QUESTIONS AND ANSWERS WITH SOLUTIONS 2024

 5 views  0 purchase
  • Course
  • ASE
  • Institution
  • ASE

ASE ELECTRICAL EXAM - GENERAL ELECTRICAL/ELECTRONIC SYSTEM DIAGNOSIS QUESTIONS AND ANSWERS WITH SOLUTIONS 2024

Preview 2 out of 12  pages

  • August 15, 2024
  • 12
  • 2024/2025
  • Exam (elaborations)
  • Questions & answers
  • ASE
  • ASE
avatar-seller
Performance
ASE ELECTRICAL EXAM - GENERAL
ELECTRICAL/ELECTRONIC SYSTEM
DIAGNOSIS QUESTIONS AND ANSWERS
WITH SOLUTIONS 2024
How are voltage tests measured? - ANSWER Voltage tests are measured with the test leads of the DMM
in parallel to the component or circuit being tested.



How do you test applied voltage? - ANSWER 1. In testing applied voltage, the negative or black test lead
of the DMM is connected to a battery or chassis ground

2. The positive red lead is then probed near the power source (e.g. a switch or fuse) to determine if the
circuit is receiving the proper voltage.



What is a handy feature of a DMM? - ANSWER Polarity is not important.

2. If the leads are reversed. the display will simply include a minus sign in front of the reading.



How are circuit voltages tested. - ANSWER Take a positive test probe and go from one circuit's power
source to the next.



Generally, the applied voltages _______________. - ANSWER Should be the same.



What is recommended when selecting a DMM to use for testing electronics circuits? - ANSWER 1. It is
recommended that it have a 10 megohm or higher impedance.

2.This is necessary to limit the effect the unit might have on accuracy when testing low current flow
circuits.

3.The lamp in the test light will draw too much current and this can damage the circuit integrity.



What should be done if it is necessary to test for voltage in an energized circuit - ANSWER 1. A
convenient way to do this is with a black-probe tool, also know as a "spoon," at various connectors in a
particular circuit.

2.This DMM accessory makes it possible to probe into the connector from behind without disconnecting
it.

, Under what conditions should you check current flow in electrical/electronic circuits etc? - ANSWER 1.
Current flow tests are used when a circuit is suspected of having higher than normal current flow, such
as a dragging blower motor, or a circuit with a low-resistance short to ground.



In testing current flow with an ammeter or DMM, what is important to remember? - ANSWER 1. It is
important to remember that the test leads are connected in series with the circuit being tested, usually
at a point near the power source.

2.The circuit must be interrupted at some point to allow the connection of the test leads.



When do most DMMs have a 10-20 amp limit? - ANSWER When measuring amperage directly through
the meter.

-Any greater current flow will blow its fuse.



How should you test DMMS if you suspect that the circuit carries more than than a 10-20 amp limit? -
ANSWER 1. A safe way to test for current flow would be to use a current clamp.

2.This device simply clamps over the wire being tested and determines current flow by measuring the
strength of the magnetic field surrounding the wire.

3. While it is extremely handy to use, it is not as accurate as routing all the current through the DMM,
especially in circuits flowing less than 10 amps.



What is low current flow usually a result of? - ANSWER Of excessive resistance in a circuit or low voltage.

2. Higher than normal current flow can generally be traced to excessive applied voltage or a shorted
component or wire.



How would you check continuity in an electrical circuit? - ANSWER 1. Auto-ranging DMMS do not have to
be adjusted to the range that is being measured.

3. While the purpose of this test is to make sure that a complete current path exists in the circuit being
tested, it is important to remember that it is not an accurate indication of circuit performance (e.g.,
excessive resistance).

4. A continuity test is most useful to quickly differentiate one circuit from another, such as trying to
locate a specific contact in a multiple pin connector.

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller Performance. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $14.49. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

72042 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$14.49
  • (0)
  Add to cart