Endoscope Reprocessing Manual Chapters 1 – 15 Verified Solutions 1. True or False: Manual cleaning should start right after pre-cleaning. - Answer: False 2. What term describes reprocessing that occurs more than one hour after the endoscope has been utilized? - Answer: Delayed processing. ...

[Show more]

Preview 4 out of 89  pages

  • August 14, 2024
  • 89
  • 2024/2025
  • Exam (elaborations)
  • Questions & answers
  • Endoscope Reprocessing Manual Chapters 1 – 15 Veri
  • Endoscope Reprocessing Manual Chapters 1 – 15 Veri
avatar-seller
CertifiedGrades
Endoscope Reprocessing Manual Chapters 1 – 15 Verified Solutions


1. True or False: Manual cleaning should start right after pre-cleaning.

- Answer: False



2. What term describes reprocessing that occurs more than one hour after the endoscope has been
utilized?

- Answer: Delayed processing.



3. When manually cleaning endoscopes, when should the cleaning solution be changed?

- Answer: For each individual endoscope.



4. True or False: Using detergents that generate excessive foam can hinder fluid contact with the
endoscope’s surface.

- Answer: True



5. After rinsing the endoscope, what should be done to the inner channels before disinfection?

- Answer: They should be purged with air.



6. How should water bottles be cleaned?

- Answer: According to the manufacturer’s instructions.



7. True or False: Testing the effectiveness of the manual cleaning process should be conducted at least
weekly, but daily is preferable.

- Answer: True



8. True or False: Automated cleaning is the most crucial step in eliminating microbial contamination
from flexible endoscopes.

- Answer: False

,9. What must be done before placing an endoscope into automated reprocessing equipment?

- Answer: Thorough manual cleaning must be performed. ✔️



10. How does the U.S. Food and Drug Administration (FDA) define validation?

- Answer: Validation is establishing, through objective evidence, that a process consistently yields a
result or product that meets predetermined specifications.



11. What are the seven general steps for manually cleaning flexible endoscopes?

1. Submerge the endoscope completely in a detergent/enzymatic solution.

2. Manually clean all internal and external surfaces, including brushing all internal channels that can
be cleaned.

3. Attach appropriate cleaning adapters following the endoscope manufacturer’s instructions.

4. Flush each internal channel with detergent or enzymatic solution.

5. Soak in detergent/enzymatic solution for the recommended duration as per the manufacturer’s
guidelines.

6. Rinse and submerge the endoscope in clean water; flush the channels.

7. Remove water from the channels by flushing them with air.



12. What should cleaning verification of flexible and semi-rigid endoscopes entail?

1. Visual inspection alongside other verifications to assess both external surfaces and internal
channels.

2. Testing the effectiveness of mechanical cleaning equipment.

3. Monitoring key cleaning parameters.



13. What are the risks associated with delayed processing of endoscopes?

- Answer: Delayed processing allows biofilm formation and soil to dry, making it more challenging to
clean the endoscope effectively.



14. What federal agency is responsible for health promotion and prevention activities in the U.S., which
also aims to enhance public health?

, - Answer: Centers for Disease Control and Prevention (CDC), established in 1946 and based in Atlanta,
GA.



15. Which type of cleaning brush minimizes the risk of cross-contamination most effectively?

- Answer: Disposable brushes.



16. What does the term 'distal' refer to in medical terminology?

- Answer: It refers to the end of an item that is farthest from the point of origin; for example, the
distal end of the femur is closest to the knee.



17. What are the three main objectives when transporting contaminated endoscopes?

1. Deliver the endoscope promptly.

2. Prevent cross-contamination during transport.

3. Protect the endoscope from damage.



18. What is the risk of a flexible endoscope that has not undergone leak testing?

1. Damaged endoscopes are susceptible to fluid invasion.

2. Unnoticed damage can hinder future procedures.



19. What is the term for fluid invading internal sections of an endoscope, leading to damage?

- Answer: Fluid invasion.



20. What are the eight steps for conducting leak testing on an endoscope?

1. Inspect for tears and damage.

2. Remove suction, air, and water valves.

3. Connect the endoscope to the leak test device.

4. Pressurize, submerging the distal portion; flex, submerge, and inspect the control head.

5. Look for bubbles and signs of damage.

6. Remove the endoscope from water and drain it.

, 7. Release the pressure from the endoscope.

8. Disconnect from the leak tester.



21. What enzyme helps break down fatty deposits, such as bone marrow and adipose tissue?

- Answer: Lipase.



22. What enzyme catalyzes the change of starch?

- Answer: Amylase.



23. True or False: Pre-cleaning at the point of use reduces the chance of biofilm formation.

- Answer: True



24. True or False: Pre-cleaning at the point of use should happen before the endoscope is detached from
the power source.

- Answer: True



25. What is the first action in point-of-use pre-cleaning after removing the endoscope from the patient?

- Answer: Remove any gross soil.



26. When placing the pre-cleaned endoscope in a container for transport, should all accessories used
during the procedure be included?

- Answer: False



27. What is the primary objective of leak testing?

- Answer: To detect any damage present on the interior and exterior of the endoscope.



The endoscope can be returned to circulation to be used for surgery if the leakage is very minimal after
leak testing

false

Pre cleaning at the point of use increase the likelihood of biofilm formation

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller CertifiedGrades. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $9.69. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

75323 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$9.69
  • (0)
  Add to cart