how do you reduce beam hardening - answer-1. Increase dose
b b b b b b b b b
2. Reduce collimation--Reduce slice thickness
b b b b
3. Increase window width
b b b
At what level does the abdominal aortal bifurcate? - answer-L4
b b b b b b b b b
What is the typical scan delay after injection of contrast media for studies of the liver? -
b b b b b b b b b b b b b b b b
answer-30-45 seconds
b b
What window settings provide the best tissue differentiation within the liver? - answer-
b b b b b b b b b b b b
window width= 140, level= 60
b b b b
What is the window settings that provide the best bone window for the pelvis? - answer-
b b b b b b b b b b b b b b b
window width=2000, window level=350
b b b
What mAs is typically used in routine CT exams of the abdomen? - answer-200-300
b b b b b b b b b b b b b
mAs
b
What is the result of the bifurcation of the abdominal aorta? - answer-The right and left
b b b b b b b b b b b b b b b
common iliac arteries
b b b
What is the anode target angle? - answer-12 degrees
b b b b b b b b
At what level do the common carotids bifurcate into the internal and external carotid
b b b b b b b b b b b b b
arteries? - answer-C3-C4
b b b
The floor of the orbit is formed by the __________ bones. - answer-maxillary and
b b b b b b b b b b b b b
zygomatic
b
The lateral wall of the orbit is formed by the ___________ bones. - answer-zygomatic
b b b b b b b b b b b b b
and sphenoid
b b
The medial wall of the orbit is formed by the _________ bones. - answer-ethmoid and
b b b b b b b b b b b b b b
lacrimal bones
b b
how do you calculate effective mAs? - answer-mAs/pitch
b b b b b b b
,define window level and window width - answer-LEVEL: a chosen midpoint in the
b b b b b b b b b b b b
grayscale
b b
WIDTH: number of grayscale values above and below the level.
b b b b b b b b b b
- The width is DIVIDED in HALF and distributed above and below the level.
b b b b b b b b b b b b b b
- Anything above the window is white
b b b b b b
- Anything below the window is black
b b b b b b
The wider the window the more grayscale values, the lower the contrast!
b b b b b b b b b b b
example:
Level 100, Width 300b b b
White = >+250 b b
Black = <-50 b b
Level 100, Width 200b b b
White = >+200 b b
Black = <0 b b
Level 100, Width 150b b b
White = >+175 b b
Black = <25 b b
factors that affect spatial and contrast resolution - answer-Spatial resolution:
b b b b b b b b b
1) focal spot
b b
2) detector width (aperture)
b b b
3) reconstruction algorithm - bone>soft tissue
b b b b b
4) slice thickness - thinner is better
b b b b b b
5) pixel/FOV/matrix
b
6) pitch - decreased pitch means no gaps
b b b b b b b
7) nyquist limitations
b b
Contrast resolution: CNR b b
1) energy of X-rays - kVp - ↑ kVp ↓ contrast
b b b b b b b b b b
2) number of X-rays - mA - ↑ mA ↓ mottle
b b b b b b b b b b
3) slice thickness - thicker is better
b b b b b b
4) reconstruction method - iterative > filtered
b b b b b b
5) reconstruction algorthith - soft tissue>bone
b b b b b
Give window levels for brain, lung, abdomen, bone - answer-Brain: W80,L+40
b b b b b b b b b b
Lung: W1500, L-400 b b
Abdomen: W400, L+50 b b
Bone: W1600, L+500 b b
What is beam hardening?
b b b
,what are the two types of beam hardening artifact?
b b b b b b b b
how do you compensate for it? - answer-1) as the X-ray beam passes through an
b b b b b b b b b b b b b b
object, lower energy photons are removed (like filtration!) leaving a "harder beam" of
b b b b b b b b b b b b b
high energy photons. This causes two artifacts:
b b b b b b b
2) Cupping: the center of a round object is darker than the periphery due to hardening
b b b b b b b b b b b b b b b
of the beam 360 degrees around the object. happens in the head
b b b b b b b b b b b b
3) Streak: these are dark bands that occur in between two dense objects - nearly all the
b b b b b b b b b b b b b b b b
photons are removed in a line between the two objects
b b b b b b b b b b
4) fixes:
b
A) Filtration: pre-hardening the beam to remove low energy photons
b b b b b b b b b
B) Calibration: using a phantom to set a compensated mA/kVp
b b b b b b b b b
C) Correct software: iterative reconstruction may help
b b b b b b
D) Avoidance: tilting the gantry of positioning the patient to avoid areas that may cause
b b b b b b b b b b b b b b
hardening.
b
ring artifact - answer-Calibration error or defective detector cause consistently
b b b b b b b b b
berroneous reading at each angular position, resulting in a circular artifact
b b b b b b b b b b
is the focal spot large or small? - answer-large 0.6-1.2 - so as not to overheat the anode
b b b b b b b b b b b b b b b b b
bfrom such a high mA b b b b
Which of the following will result in an increased voxel size: B increased slice thickness
b b b b b b b b b b b b b b
- answer-A)decreased reconstruction FOV B) increased slice thickness C) increased
b b b b b b b b b b
matrix D) none of these
b b b b b
If a tissue with a CT number of +300 appears white on the image, which of the following
b b b b b b b b b b b b b b b b b
bare the window width and window level selected: A)window level =0, window width
b b b b b b b b b b b b
b=500 B)window level= +300, window width= 500 C)window level =+100, window width
b b b b b b b b b b b
b=1000 D)none of these - answer-A) window level =0, window width =500
b b b b b b b b b b b
What is the volume of a voxel if a slice thickness of 3 mm, a 512x512 matrix & a
b b b b b b b b b b b b b b b b b b
reconstruction field of view of 25.6cm are used A) 0.75mm³ B)1.5mm³ C) 6.0mm³
b b b b b b b b b b b b b
D)none of these - answer-A. Solve this by finding the pixel size first FOV/matrix size ...
b b b b b b b b b b b b b b b b
that is 0.5 ... now square that 0.25 .... multiply that by slice thickness and you get 0.75
b b b b b b b b b b b b b b b b b b
Which of the following parameters is responsible for partial volume averaging: A) matrix
b b b b b b b b b b b b
size B) kVp C)slice thickness D) patient dose - answer-C
b b b b b b b b b b
Voxel equation - answer-pixel area x section thickness
b b b b b b b
What is interpolation? - answer-Mathematical method for taking SPIRAL data and
b b b b b b b b b b
viewing it as AXIAL images
b b b b b
, Bone windows - answer-2000-4000 WW
b b b b
200-400 WL b
Lung windows - answer-1400-1600 WW
b b b b
(-)400-600 WL b
Modular Transfer Function? - answer-graphical representation of SPATIAL
b b b b b b b
RESOLUTION measured in lp/cm, tells how small you can scan without blurring
b b b b b b b b b b b b
Decrease partial volume averaging? - answer-Reduce slice thickness
b b b b b b b
Which portion of the pancreas is the most common site for tumors?; and where located?
b b b b b b b b b b b b b b
- answer-The head of the pancreas. It is located approximately at T12
b b b b b b b b b b b b
LUNG WINDOW b
(-) IS AIR - answer-2000 WW and -200 WL =
b b b b b b b b b
The Hounsfield unit that is -1000 most likely represents which of the following? -
b b b b b b b b b b b b b
answer-Air
b
Relative to CT topography, slice thickness is best represented by which of the following
b b b b b b b b b b b b b
axes? - answer-Z axis
b b b b
What unit is the basis for exposure based on ionization in air? - answer-mR or C/kg
b b b b b b b b b b b b b b b
What radiation unit considers the biological effectiveness of radiation exposure? -
b b b b b b b b b b
answer-mrem or mSv
b b b
"Fan" beam technology first historically came on the scene with which acquisition
b b b b b b b b b b b
bgeometries? - answer-Second b b
"Rotate-rotate" applies to which of the following geometries? - answer-Thirdb b b b b b b b b
In CT what imaging plane is the pituitary best visualized? - answer-coronal
b b b b b b b b b b b
The third ventricle of the brain communicates with the fourth ventricle through the -
b b b b b b b b b b b b b
answer-Cerebral aqueduct
b b
refers to an excessive Amount of nitrogenous materials in the blood and is a symptom
b b b b b b b b b b b b b b
bof renal failure. - answer-Azotemia
b b b b
Which paranasal sinus is usually the last to fully develop? - answer-Frontal
b b b b b b b b b b b
What is the average annual radiation dose? - answer-2 rem
b b b b b b b b b
10 rem converted to Sieverts is what? - answer-0.1 Sv
b b b b b b b b b
The benefits of buying summaries with Stuvia:
Guaranteed quality through customer reviews
Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.
Quick and easy check-out
You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.
Focus on what matters
Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!
Frequently asked questions
What do I get when I buy this document?
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
Satisfaction guarantee: how does it work?
Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.
Who am I buying these notes from?
Stuvia is a marketplace, so you are not buying this document from us, but from seller ParadisePro. Stuvia facilitates payment to the seller.
Will I be stuck with a subscription?
No, you only buy these notes for $13.99. You're not tied to anything after your purchase.