On a unit that has a receiver/storage tank, and the condenser is on the roof with an evaporator on the
first floor, recovery should begin from the liquid line entering the ________. - ANSWER-evaporator
After recovery, refrigerant may be returned to the appliance from which it was removed or to another
appliance owned by the same person without being _____ or _____. Exception: MVAC like appliances. -
ANSWER-recycled reclaimed
The technician should always ______ an empty recovery cylinder before transferring _______ to the
cylinder. - ANSWER-evacuate refrigerant
______ ______, self-sealing hoses, or hand valves should be used (as low loss fittings) to minimize
refrigerant release when hoses are connected and disconnected. - ANSWER-quick couplers
Quick couplers, ____ ____ ____, or hand valves should be used (as low loss fittings) to minimize
refrigerant release when hoses are connected and disconnected. - ANSWER-self sealing hoses
Quick couplers, self-sealing hoses, or _____ _____ should be used (as low loss fittings) to minimize
refrigerant release when hoses are connected and disconnected. - ANSWER-hand valves
Appropriate recovery equipment has been certified by an EPA approved laboratory (UL or ETL) to meet
or exceed ______ standards. - ANSWER-ARI
Refrigerant recovery and/or recycling equipment manufactured after November 15, 1993, must be
certified and _______ by an EPA ______ equipment testing organization to meet EPA standards. -
ANSWER-labeled approved
Refrigerant recovery and/or recycling equipment manufactured after _________, must be certified and
labeled by an EPA approved equipment testing organization to meet EPA standards. - ANSWER-
november 15 1993
,Required Recovery Levels in Inches of Mercury:
HCFC-22 appliance or isolated component of such, normally containing LESS than 200 lbs. of refrigerant:
Equipment
before 11/15/93_____
after 11/15/93_____ - ANSWER-0 0
Required Recovery Levels in Inches of Mercury:
HCFC-22 appliance or isolated component of such, normally containing MORE than 200 lbs. of
refrigerant:
Equipment
before 11/15/93_____
after 11/15/93_____ - ANSWER-4 10
Required Recovery Levels in Inches of Mercury:
Other high pressure appliance or isolated component of such, normally containing LESS than 200 lbs. of
refrigerant:
Equipment
before 11/15/93_____
after 11/15/93_____ - ANSWER-4 10
Required Recovery Levels in Inches of Mercury:
Other high pressure appliance or isolated component of such, normally containing MORE than 200 lbs.
of refrigerant:
Equipment
before 11/15/93_____
after 11/15/93_____ - ANSWER-4 15
Required Recovery Levels in Inches of Mercury:
Very high pressure appliances
, Equipment
before 11/15/93_____
after 11/15/93_____ - ANSWER-0 0
After reaching the desired vacuum, the technician should wait a few minutes to see if the system
pressure rises, which would indicate there is still refrigerant in _____ form or in the ____. - ANSWER-
liquid oil
What psig is considered Atmospheric pressure - ANSWER-0 psig
Appliances can be evacuated to _______ pressure, if _____ make evacuation to the prescribed level
unattainable. - ANSWER-atmospheric leaks
The technician must isolate a _______ _______ system in order to recover refrigerant. - ANSWER-
parallel compressor
Failure to isolate a parallel compressor system will cause an open equalization connection that will
prevent refrigerant _______. - ANSWER-recovery
_______ ________ recovery equipment cannot be used on appliances containing more than 15 pounds
of refrigerant. - ANSWER-System Dependent
System dependent recovery equipment cannot be used on appliances containing more than _____
pounds of refrigerant. - ANSWER-15
Under EPA regulations, a "major repair" means any Maintenance, service or repair involving the removal
of any or all of the following components: the ______, the condenser, the evaporator or an auxiliary
heat exchanger. - ANSWER-compressor
Under EPA regulations, a "major repair" means any Maintenance, service or repair involving the removal
of any or all of the following components: the compressor, the ______, the evaporator or an auxiliary
heat exchanger. - ANSWER-condenser
The benefits of buying summaries with Stuvia:
Guaranteed quality through customer reviews
Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.
Quick and easy check-out
You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.
Focus on what matters
Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!
Frequently asked questions
What do I get when I buy this document?
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
Satisfaction guarantee: how does it work?
Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.
Who am I buying these notes from?
Stuvia is a marketplace, so you are not buying this document from us, but from seller Settings. Stuvia facilitates payment to the seller.
Will I be stuck with a subscription?
No, you only buy these notes for $22.49. You're not tied to anything after your purchase.