100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached
logo-home
CT image production post course assessment questions with correct answers. $10.29   Add to cart

Exam (elaborations)

CT image production post course assessment questions with correct answers.

 2 views  0 purchase
  • Course
  • Computered Tomography
  • Institution
  • Computered Tomography

CT image production post course assessment questions with correct answers.

Preview 3 out of 19  pages

  • August 3, 2024
  • 19
  • 2024/2025
  • Exam (elaborations)
  • Questions & answers
  • Computered Tomography
  • Computered Tomography
avatar-seller
Professorkaylee
CT image production post course
assessment questions with correct
answers.

The phantom pictured below contains only water. Based on the ROI readings what problem should be
reported to the medical physicist? ANS - Unacceptable uniformity



What artifact is visible in the image below in the posterior portion of the patient's abdomen? ANS -
Beam hardening artifact



What two computed tomography (CT) artifacts are demonstrated in the following image? (Select two)
ANS - Beam hardening artifact

Ring artifact



A technologist review a patient's EMR for evidence of a gadolinium allergy prior to performing a scan
with contrast. is this a hippa violation? ANS - This is NOT a hippa violation



Compared to a pitch of 1.2, a pitch of 1 will demonstrate what two differences? (Select two)

1. Increased dose

2. increased spatial resolution

3. increased total scan time ANS - Increased dose

Increased spatial resolution



Which part of the PACS system houses all of the historic digital image data along with the current digital
data being generated by the modalities? ANS - Archive server



Consider a PACS network running through a traditional internet network. What is the primary advantage
of this network architecture? ANS - The PACS archive server can be accessed from any internet-
connected computer

,What difference in image processing accounts for the visible difference between the following two
images of the brain? ANS - Back projection filter



During spiral scanning, attenuation data from the patient is first organized in a helical pattern. The
process of converting this information into axial sections is accompanied by through: ANS -
interpolation



"Matrix size" in computed tomography (CT) refers to which of the following? ANS - The number of pixels
in the matrix



Consider a computed tomography (CT) image that was initially displayed with a 300 window width (WW)
and a 30 window level (WL). DECREASING the window level from 30 to 0 will have what effect on the
image? ANS - decreased brightness



If the pitch is greater than one, this results in: ANS - Scan data without overlap or missing views



The contrast resolution of a CT system is recorded with which of these units? ANS - HU



Compared to a pitch of 1, a pitch of 1.137 will demonstrate what three differences? (Select three)



1. decreased scan time

2. decreased pt. dose

3. decreased spatial resolution ANS - 1. decreased scan time

2. decreased pt. dose

3. decreased spatial resolution



What is the main DISADVANTAGE of using thick detector rows? ANS - decreased contrast resolution



ideally, the patient worklists on imaging equipment should be automatically populated from
examination request placed though the: ANS - Electronic medical record ( EMR)

, After completing a routine scan of the chest the radiologist request a sagittal image series with 5mm
slices. this request can be completed using which of these imaging techniques? ANS - multiplaner
reformation



What is the principle function of the data acquisition system (DAS) in CT? ANS - Reconstruct raw data
into image data



The following image shows excessively high contrast. Improving the contrast could be accomplished by:
ANS - Increasing the WW



Cone beam artifact is increased under what circumstances? ANS - Use a wide X-ray beam



Which two types of reconstruction algorithm should be used to view bony injuries to the thorax? (Select
two) ANS - Edge enhancing algorithms Smoothing algorithms



Compared to a 2mm reconstruction slice thickness a 1mm slice thickness will result in

1. decreased image noise

2. decreased spatial resolution

3. more total image slices ANS - more total image slices



Which of the following is a disadvantage of accessing the PACS server through the internet on a basic
desktop computer

1. decreased image quality

2. inability to access archived studies

3. increased archived retrieves time ANS - decreased image quality



Ring artifact can be the result of ANS - using a large display field of view



What controls the physical size of the X-ray beam? ANS - Pre patient collimators

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller Professorkaylee. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $10.29. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

67163 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$10.29
  • (0)
  Add to cart