100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached
logo-home
HVAC JOURNEYMAN EXAM /TEST EXAM WITH OVER 300 QUESTIONS AND CORRECT ELABORATED ANSWERS ALREADY RATED BY EXPERTS AS THE BEST EXAM (GRADED A+) $19.99   Add to cart

Exam (elaborations)

HVAC JOURNEYMAN EXAM /TEST EXAM WITH OVER 300 QUESTIONS AND CORRECT ELABORATED ANSWERS ALREADY RATED BY EXPERTS AS THE BEST EXAM (GRADED A+)

 5 views  0 purchase
  • Course
  • Institution

HVAC JOURNEYMAN EXAM /TEST EXAM WITH OVER 300 QUESTIONS AND CORRECT ELABORATED ANSWERS ALREADY RATED BY EXPERTS AS THE BEST EXAM (GRADED A+) A listed smoke damper designed to resist the passage of smoke shall be provided at each point in a duct or air transfer opening penetrates a: (A)smoke barr...

[Show more]

Preview 4 out of 51  pages

  • July 10, 2024
  • 51
  • 2023/2024
  • Exam (elaborations)
  • Questions & answers
avatar-seller
HVAC JOURNEYMAN EXAM 2024-2025/TEST EXAM

WITH OVER 300 QUESTIONS AND CORRECT

ELABORATED ANSWERS ALREADY RATED BY

EXPERTS AS THE BEST EXAM (GRADED A+)


A listed smoke damper designed to resist the passage of smoke shall be provided at

each point in a duct or air transfer opening penetrates a: (A)smoke barrier wall (B)fire

rated wall (C)interior wall (D)corridor wall - ANSWER- Corridor wall (IMC 607.5.4)



Flexible air duct may be what length? (A)10' (B)2' (C)14' (D)6' - ANSWER- 14' (IMC

603.6.1.1)



The maximum vertical distance between the front lower lip of a canopy Type 1 hood and

the appliance surface shall be ____ feet: (A)5' (B)3' (C)6' (D)4' - ANSWER- 4' (IMC

507.4.1)



The return air duct to a blower type warm air furnace is being replaced, how many sq.

inches of free air are required per 1,000 BTU or rated capacity of the furnace? (A)3"

(B)1" (C)4" (D)2" - ANSWER- 2" (Fuel Gas Code 9.3.3.2)

,The existing terminals of a mechanical draft system shall not be less than ___ feet

above finished ground level where located adjacent to public walkways: (A)7' (B)2' (C)8'

(D)5' - ANSWER- 7' (IMC 804.3.4 #1)



What device is installed to prevent a back draft occurring in an appliance? (A)Power

draft vent (B)Vent cap (C)Saftey relief valve (D)Draft hood - ANSWER- Draft hood (Fuel

Gas Code, 3.3.33)

Minimum distance between the lowest edge of a grease filter and the cooking surface

with exposed flame or burners is: (A)42" (B)6" (C)48" (D)24" - ANSWER- 24" (IMC

Table 507.2.8)



Non-metallic ducts shall have a flame spread index of ___ or less and a smoke-

devolped index of ___ or less: (A)100,200 (B)84,723 (C)50,100 (D)25,50 - ANSWER-

25,50 (IMC 602.2.1)



A blower fan used for the purpose of distributing supply air to a room, space, or area is

a: (A)Air-handling unit (B)Return fan (C)Make-up fan (D)Exhaust fan - ANSWER- Air

handling unit (IMC Chapter #2)



Maximum flame spread distance of ___ feet for combustable electrical wires, cables,

and optical fiber cables exposed within a plenum: (A)30' (B)3' (C)70' (D)5' - ANSWER-

5' (IMC 602.2.1.1)

,Where all combustion air is provided by a mechanical air supply system, the combustion

air shall be supplied from outdoors at the minimum rate of: (A)100ft3/1000BTU/hr

(B)0.35ft3/1000BTU/hr (C) 25ft3/1000BTU/hr (D)50ft/1000BTU/hr - ANSWER-

0.35ft3/1000BTU/hr (Fuel Gas Code, 9.3.6)



A chimney for a residential type or low-heat appliances shall exceed at least ___ feet

above the highest point where it passes through the roof of a building? (A)5' (B)2' (C)10'

(D)3' - ANSWER- 3' (Fuel Gas Code, 12.6.2.1)



A chimney for a low heat appliance must withstand a continuous flue gas temperature

not exceeding ___: (A)1000 (B)1800 (C)800 (D)1200 - ANSWER- 1000 (IMC 202

Appliance Type)



When running flue gas pipe, any angle greater than ___ from the vertical is considered

to be horizontal: (A)30 (B)60 (C)45 (D)90 - ANSWER- 45 (Fuel Gas Code, 12.7.3.2)



A direct vent appliance with an input over 50,000BTU/hr, shall have at least ___ inches

from any air opening into a building: (A)12 (B)6 (C)18 (D)9 - ANSWER- 12 (Fuel code

12.9.3)



Unless otherwise specified by the designer, that sealing requirements do not contain

provisions to: withstanding temperatures higher than ___ degrees F, or lower than ___

, degrees F: (A)120, 40 (B)175, -30 (C)40,120 (D)212, 32 - ANSWER- 120, 40 (SMACNA

S1.9 e. 4. )



What minimum pitch per foot is required for the horizontal run of a vent connector?

(A)3/4" (B)1/4" (C)1" (D)1/2" - ANSWER- 1/4" (Fuel code 12.11.7)



Maximum allowable load size for 1"x18Ga. hanger is: (A)420lbs (B)260lbs (C)700lbs

(D)320LBS - ANSWER- 420lbs (SMACNA Table 5-1)



At least ___ feet of clearance shall be available between the access opening and the

edge of the roof: (A)8' (B)4' (C)10' (D)6' - ANSWER- 6' (Fuel code 9.4.3.3)



A type 1 hood shall have what minimum clearance to combustable materials? (A)14"

(B)6" (C)18" (D)10" - ANSWER- 18" (IMC 507.2.6)



Unless complying as underground duct per section 603.8, ducts shall be installed a

minimum of ___ inches from the earth: (A)4" (B)2" (C)6" (D)3' - ANSWER- 4" (IMC

603.14)



Smoke detectors shall be located downstream of an air filter and ahead of any branch

connectors in a return stream with flow greater than: (A)4,000CFM (B)2,000CFM

(C)5,000CFM (D)3,000CFM - ANSWER- 2,000CFM (IMC 606.2.1)

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller samnyoki. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $19.99. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

78252 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$19.99
  • (0)
  Add to cart