CBSPD chapters: 10, 5, 6 Questions with
correct answers


If the steam pressure is too low for the set temperature - ANSWER-Superheating
can occur

Wet steam can cause - ANSWER-Wet packs

AAMI recommends that the temperature in the sterilization area be: -
ANSWER-68-73 degrees

AAMI recommends that the humidity is the sterilization area be -
ANSWER-30%-60%

The recommended ventilation in the sterilization are is—— air exchanges per
hour under positive pressure - ANSWER-10

AAMI recommends that the temperature in the sterilizer access area be —- with
— air exchanges per hour and under — pressure - ANSWER-75-85/10/negative

The only 3 areas in SPD that should have negative pressure are: -
ANSWER-Decon, the sterilizer access area, EVS closet

— is the absence of all forms of microbial life, including bacterial spores -
ANSWER-sterility

An item is considered sterile if there is less than —— chance that a viable
microorganism has survived the sterilization process. This is reflected
numerically as —- - ANSWER-One in a million; 10(-6)

SAL= - ANSWER-Sterility Assurance Level

— kills microorganisms by denature great the protein - ANSWER-Steam

,— is the most common form of sterilization for items that are heat- and
moisture-tolerant - ANSWER-steam sterilization

Three parameters of steam sterilization cycles are - ANSWER-saturated steam
under pressure, time, and temperature

— are used in prevacuum sterilized and in steam-flush pressure-pulse (SFPP) -
ANSWER-Dynamic-air-removal cycles

— remove air by drawing series of vacuums with an injection of steam between
each vacuum pull. - ANSWER-Prevacuum sterilizers

Performed daily to detect air leaks or inadequate air removal from prevacuum
sterilzers - ANSWER-Bowie-Dick test

Incoming steam displaces residual air through the drain at the bottom of the
sterilizer chamber: - ANSWER-Gravity-displacement cycles

Because there is no mechanical air removal in a —, a Bowie-Dick test is not
required for — or sterilizers - ANSWER-Gravity-displacement

In most healthcare facilities, steam is generated inside of a: - ANSWER-Boiler

The required pressure of steam as it enters the jacket is usually: -
ANSWER-60-80psig

For a sterilizer operating at 270 degrees, the sterilizer gauge will show: -
ANSWER-28-30 lbs of pressure

Provides heat inside the chamber to prevent condensation from forming on the
chamber walls: - ANSWER-An insulating jacket

The sterilizers - - - is locates in the drain line - ANSWER-Heat-sensing
thermometer

The coldest part of sterilizer is - ANSWER-The drain line

, All PCDs should be placed on the —, directly over the — - ANSWER-Bottom
rack, drain line

The Bowie-Dick test pack is placed - ANSWER-On the bottom rack above the
drain line

The phases of steam sterilization cycles are: - ANSWER-Conditioning,
sterilization/exposure/"holding, Exhaust, Drying

During this phase, air is removed from the sterilization chamber and steam is
injected - ANSWER-Conditioning phase

In this phase, the exposure temperature is maintained for the prescribed amount
of time. - ANSWER-Sterilization/exposure/holding

After the exposure phase, steam is — from the sterilizer through the chamber
drain line is this phase: - ANSWER-Exhausted, Exhaust phase

After the steam has been exhausted, the sterilizer goes into the - of the cycle
which typically lasts about 30 minutes - ANSWER-Drying phase

The cycle for wrapped items using Dynamic-air-removal steam is: - ANSWER-• 4
minutes @ 270 and 28-30 psi
• 3 minutes @ 275 and 38-30 psi

The cycle for wrapped items using Gravity-displacement steam: - ANSWER-• 30
minutes @ 350 and 15 psi
• 15-20 minutes @ 270 and 27 psi
• 10 minutes @ 275 and 30 psi

To verify that the cycle met the requirements for sterilization, a — should be
included in the load (whether or not the load contains implantable devices) -
ANSWER-BI PCD

—- is usually performed when an unplanned event occurs -
ANSWER-Immediate-Use steam sterilization (IUSS)

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller TUTORSON. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $13.49. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

79276 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$13.49
  • (0)
  Add to cart