100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached
logo-home
LEED Green Associate Exam Questions With Answers $11.09   Add to cart

Exam (elaborations)

LEED Green Associate Exam Questions With Answers

 3 views  0 purchase
  • Course
  • Institution

LEED Green Associate Exam Questions With Answers [EQ] Construction Indoor Air Quality Management Plan Credit Intent: to promote the well-being of construction workers and building occupants by minimizing indoor air quality problems associated with construction and renovation Credit Requireme...

[Show more]

Preview 4 out of 58  pages

  • June 24, 2024
  • 58
  • 2023/2024
  • Exam (elaborations)
  • Questions & answers
avatar-seller
LEED Green Associate Exam Questions With
Answers
[EQ] Construction Indoor Air Quality Management Plan Credit

Intent: to promote the well-being of construction workers and building occupants by minimizing
indoor air quality problems associated with construction and renovation

Credit Requirements:

- Develop an indoor air quality (IAQ) plan for construction and preoccupancy phases of the building

- Meet or exceed Control Measures from SMACNA IAQ Guidelines for Occupied Buildings Under
Construction, 2nd edition, 2007

- Protect absorptive materials from moisture damage

- Install MERV 8 or class F5 at return air grille and return or transfer duct inlet opening for any
equipment that will be operated during construction. Install final design filtration media immediately
prior to occupancy

- Prohibit use of tobacco inside the building and within 25 of the building entrance during
construction

Ref: SMACNA (Sheet Metal and Air-Conditioning National Contractors Associations) IAQ Guidelines for
Occupied Buildings Under Construction, 2nd edition, 2007

- ASHRAE 52.2-2007

- CEN Standard EN 779-2002



[EQ] Minimum Indoor Air Quality Prereq and Enhanced Indoor Air Quality Credit

Intent: to contribute to the comfort and well-being of building occupants by establishing minimum
standards for indoor air quality (IAQ)

Prereq Requirements:
Mechanically Ventilated Spaces (Ventilation)
Option 1. ASHRAE Standard 62.1-2010
Use ASHRAE Standard 62.1-2010 to establish minimum outdoor air intake flow using the Ventilation
Rate Procedure and follow Sections 4-7 (or local code if more stringent)

Option 2. CEN Standards EN 15251-2007 and EN 13779-2007
*Non-US projects only

Mechanically Ventilated Spaces (Monitoring)
Variable Air Volume (VAV) Systems
- Provide direct outdoor air intake monitoring with an alarm if airflow varies by more than 15% from
setpoint

Constant-Volume Systems
- Balance outdoor airflow to at least the design minimum of ASHRAE Standard 62.1-2010 and install a
current transducer

Naturally Ventilated Spaces (Ventilation)

,- Determine minimum air opening space configuration requirements using natural ventilation
procedure using ASHRAE Standard 62.1-2010 (or local code if more stringent)
- Follow ASHRAE Standard 62.1-2010 Section 4 (or local code if more stringent)
- Confirm natural ventilation will be effective using CIBSE AM10

Naturally Ventilated Spaces (Monitoring)
- Measure the exhaust airflow and have an alarm if it varies by more than 15% from setpoint
- Automatic indication devices for windows and other operable devices used to meet minimum
requirements with an alarm if any opening is closed during occupied hours
- CO2 monitoring in each thermal zone from 3-6 ft above the floor. CO2 monitors to have visual or
audio indicator (or alert to the building automation system) if CO2 levels vary by 10% from setpoint
(calculated using ASHRAE Standard 62.1-2010)

** Residential Requirements (Additional)
- No unvented combustion appliances (e.g. decorative logs)
- Carbon Monoxide (CO) monit


USGBC Mission
To transform the way buildings and communities are designed, built and operated, enabling an
environmentally and socially responsible, healthy, and prosperous environment that improves the
quality of life.


What does LEED stand for?
Leadership in Energy and Environmental Design


ASHRAE 90.1-2010
Used for [EA] baseline building energy performance


Green-E Energy Product Certification
Used for [EA] green energy and carbon offset certification


CA Dept. Public Health Standard Method v1.1 - 2010
Used for [IEQ] to determine low-emitting products


Triple Bottom Line
People, Planet, Profit; measures an organization's social, environmental, and financial performance


Why build green? (People: Health & Wellbeing)
- Quality of Life
- Access to Nature
- Community


Why build green? (Planet: Resource Management & Climate Change)
- Fossil Fuels (Petroleum, Gas, Coal)
- Water Scarcity
- Building Materials Management
- Soil Erosion

,Why build green? (Profit: Financial Benefits)
- Improved Marketability
- Increased Occupancy & Rental Rates
- Reduced Operating Costs (Energy & Water Savings)


7 LEED Impact Categories / System Goals
- Climate Change
- Human Health
- Water Resources
- Biodiversity
- Green Economy
- Community
- Natural Resources


What does GBCI (Green Building Certification Institute) do?
Administers LEED Accredited Professionals & LEED Building Certification


What does USGBC (United States Green Building Council) do?
Develops & Maintains LEED Rating System


LEED Rating Levels
Certification - 40 points (40%)
Silver Certification - 50 points (50%)
Gold Certification - 60 points (60%)
Platinum Certification - 80 points (80%)


3 Minimum Project Requirements (MPRs)
The requirements that a building must meet before it can consider LEED certification.

1. Must be in a permanent location on existing land
2. Must use reasonable LEED boundaries
3. Must comply with project size requirements
- BD+C and O+M must be at least 1000 sq ft
- Interior must be at least 250 sq ft
- Neighborhood must have at least 2 habitable buildings and be a max of 1500 acres
- Homes must meet the definition for a dwelling unit (permanent provisions for living, sleeping,
eating, cooking and sanitation)


Full-time equivalent (FTE)
The designation for a building occupant who spends 40 hours per week in the project building.
Transient occupants (students, visitors, shoppers, customers) have FTE values based on their hours
per week divided by 40.


What credits are FTE used for?
- Bicycle Storage & Shower
- Green Vehicles
- Parking Capacity
- Water Fixtures

, What does BD+C stand for?
Building Design & Construction


BD+C Adaptations (8)
- New Construction & Major Renovation
- Core & Shell Development
- Schools
- Retail
- Data Centers
- Warehouses & Distribution Centers
- Hospitality
- Healthcare


BD+C Project Scope
- Whole Building Design & Construction
- Buildings (all except homes)
- Major Renovations (HVAC, envelope modifications, major interior rehabilitation


Core & Shell certification is for buildings that _______________ ?
don't include a complete interior fit-out


What does ID+C stand for?
Interior Design & Construction


ID+C Adaptatons (3)
- Commercial Interiors
- Retail
- Hospitality


ID+C Project Scope
Interior Spaces that are a complete interior fit-out


What does O+M stand for?
Operations & Maintenance


O+M Adaptations (6)
- Existing Buildings
- Retail
- Schools
- Hospitality
- Data Centers
- Warehouses & Distribution Centers


O+M Project Scope
- Existing Buildings
- Little to no construction

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller LectDan. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $11.09. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

72042 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$11.09
  • (0)
  Add to cart