Oil Burners license test
A cad cell primary control can lock out safety because - correct answer-All of the above-
dirty, faulty, not sensing flame
A Call for too much heat on a hot water heating job may be caused by - correct
answer-Thermostat wire is shorted out
A common cause of delayed ignition is a delayed oil solenoid valve - correct answer-True
A decrease in CO2 with an increase in excess air will give a drop in stack temperature -
correct answer-True
A high limit device installed on a forced air furnace is controlled by - correct
answer-Temperature
A non-resident steam or hot water boiler having a minimum safety relief valve capacity over
200,000 BTU/hr requires certificate of inspection from the department of fire services -
correct answer-Prior to the initial firing, every 3 years after
A storage tank that has greater than —— gallon capacity, other than an outside above
ground tank shall be filled only through a fill pipe which terminates outside the building -
correct answer-60
Adequate breaching draft will always reduce the risk of CO in a structure - correct
answer-True
All persons assisting and working under the supervision of a person holding a certificate as
an oil burner technician must hold current apprentice certificates issued by Department of
fire services - correct answer-True
All primary control safety shutdowns are caused by no combustion - correct answer-False
Corrosion in the flu pipe may occur if - correct answer-Flue gas temperature is below the
dewpoint and sulfur oxide's combine with water
Delayed ignition may be caused by - correct answer-Unvented pressure regulator
Dirt or lint build up in the bevel of the burner blades will - correct answer-Reduce the amount
of combustion air
Doing a combustion pretest on and oil burning appliance will not tell you anything this is why
they generally are performed - correct answer-False
, Energizing the ignition circuit during the entire burn cycle reduces - correct answer-Ignition
component life
Flue pipes must terminate outside of the building at a point at least —— feet away from any
building opening at the same or lower level - correct answer-4
From whom must you obtain a permit for removal of a fuel oil storage tank - correct
answer-The head of the local fire department
Fuel can be transferred from a tank to an appliance by pressurizing the tank - correct
answer-False
Fuel return piping from an appliance shall - correct answer-Enter the top of the tank
High viscosity problems brought on by cold oil may be minimized by - correct answer-All of
the above
How many BTUs are in one gallon of No.2 fuel oil - correct answer-140,000 BTUs
If a cad cell is sensing light when there is a call for heat the primary control - correct
answer-Will lockout on safety
If a high limit is installed to prevent high boiler water temperature what is the function of the
low limit - correct answer-To maintain temperature for domestic hot water
If a newly installed oil line cannot be fully visually inspected you must - correct answer-Install
an oil safety valve
If a split phase burner motor does not operate after the primary control has been reset and
the voltage to the motor is correct you should check the - correct answer-Capacitor
If a stack type controller fails you must - correct answer-Replace it with an approved type
controller
Increasing the fuel pump pressure will - correct answer-Increase the flow rate
Installation of oil safety valves and oil pressure reducing valve - correct answer-Reduces the
chance of a return line leak
It is best to connect flue units as a one pipe system instead of a two pipe system because -
correct answer-One pipe leads to longer filter life and eliminates leaking return lines
It is common for the oil burner and blower to come on at the same time on a warm air
system - correct answer-False
Materials who's electrons are so loosely bound that they can be persuaded to move with
very little pressure allowing electricity to flow are called - correct answer-Conductors
The benefits of buying summaries with Stuvia:
Guaranteed quality through customer reviews
Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.
Quick and easy check-out
You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.
Focus on what matters
Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!
Frequently asked questions
What do I get when I buy this document?
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
Satisfaction guarantee: how does it work?
Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.
Who am I buying these notes from?
Stuvia is a marketplace, so you are not buying this document from us, but from seller Hkane. Stuvia facilitates payment to the seller.
Will I be stuck with a subscription?
No, you only buy these notes for $7.99. You're not tied to anything after your purchase.