100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached
logo-home
Home Inspection Course National Preparation Exam Q&A 2024 $15.49   Add to cart

Exam (elaborations)

Home Inspection Course National Preparation Exam Q&A 2024

 9 views  0 purchase
  • Course
  • Home inspection
  • Institution
  • Home Inspection

Home Inspection Course National Preparation Exam Q&A 2024 The main difference between a laundry tub pump and a sump pump is (a) laundry tub pumps can handle lint (b) sump pumps are laundry capacity (c) laundry tub pumps operate on 120 volt, and sump pumps operate only on 240v power (d) su...

[Show more]

Preview 3 out of 20  pages

  • April 30, 2024
  • 20
  • 2023/2024
  • Exam (elaborations)
  • Questions & answers
  • Home inspection
  • Home inspection
avatar-seller
TIFFACADEMICS
Home Inspection Course National
Preparation Exam Q&A 2024


The main difference between a laundry tub pump and a sump pump is

(a) laundry tub pumps can handle lint
(b) sump pumps are laundry capacity
(c) laundry tub pumps operate on 120 volt, and sump pumps operate only on 240v
power
(d) sump pumps are manual, and laundry tub pumps are automatic - CORRECT
ANSWER -(a) laundry tub pumps can handle lint

All of the following are common HRV problems
except

(a) missing filters
(b) dirty heat exchanger core
(c) lack of a trap in the condensate drain
(d) flow measuring stations located on warm side ducts - CORRECT ANSWER -(d) flow
measuring stations located on warm side ducts

Squeaking subflooring is an indication of

(a) over spanned joists
(b) undersized beams
(c) poor fastening of subfloors
(d) undersized subfloors - CORRECT ANSWER -(c) poor fastening of subfloors

High efficiency gas furnaces installed in old ductwork tend to have

(a) higher maintenance
(b) excess temperature rise
(c) shorter life spans
(d) all of the above - CORRECT ANSWER -(c) shorter life spans

Most radiant heating systems are located

(a) in the ceiling
(b) in the floors
(c) on exterior walls below windows
(d) in light weight concrete panels - CORRECT ANSWER -(a) in the ceiling

Which group of terms does not go together?
1 / 3


(a) pier, column, truss
(b) rafter, truss, purlin
(c) joist, beam, girder
(d) stud, header, sill - CORRECT ANSWER -(a) pier, column, truss

The cable is protected by 60 -amp breakers at the main panel. You should make sure
that

(a) the cable is protected in a ventilated metal raceway
(b) the cable is in rigid conduit
(c) the cable is no longer than three feet
(d) the subpanel is rated to handle at least 60 amps.
(d) the subpanel is rated to handle at least 60 amps. - CORRECT ANSWER -(d) the
subpanel is rated to handle at least 60 amps.

If there is no water in the boiler, the low water cutouts prevents the

(a) circulator from operating
(b) burner from firing
(c) pressure reducer from adding water
(d) entrapment of air in the air separator - CORRECT ANSWER -(b) burner from firing

A house has service entrance conductors designed for 100 amps and a main
disconnect rated at 100 amps. Which of these conditions is unsafe?

(a) The service entrance box is rated at 125 amps
(b) The service box is rated at 75 amps
(c) The distribution panel is rated at 125 amps
(d) The distribution panel is rated at 200 amps - CORRECT ANSWER -(b) The service
box is rated at 75 amps

Which of the following steam systems is commonly converted to hot water?

(a) A one pipe, up -feed system
(b) A one pipe, down -feed system
(c) A two -pipe system
(d) A one pipe, parallel flow system - CORRECT ANSWER -(c) A two -pipe system

All of the following are basic components of a masonry wood -burning fireplace except

(a) A damper
(b) A throat
(c) A smoke shelfs
(d) A heat circulator - CORRECT ANSWER -(d) A heat circulator

2 / 3

Copper -tube boilers typically have:

a) Better heat transfer characteristics, and longer lifespans than cast -iron boilers
(b) Better heat transfer characteristics, but shorter lifespans than cast -iron boilers
(c) Worse heat transfer characteristics, but longer lifespans than cast -iron boilers
(d) Worse heat transfer characteristics, and shorter lifespans than cast -iron boilers -
CORRECT ANSWER -(b) Better heat transfer characteristics, but shorter lifespans than
cast-iron boilers

Which of the following is a similarity between furnaces and boilers?

(a) Piping
(b) A low -level safety device
(c) High -temperature limit switches
(d) Backflow preventers - CORRECT ANSWER -(c) High -temperature limit switches

Heat exchanger diagnosis is easier than on furnaces because the heat exchanger will
leak when it has failed.

(a) True
(b) False - CORRECT ANSWER -(a) True

List the four safety controls found on hydronic systems:

(a) Pressure relief valve, high temperature limit, low -water cutout, backflow preventer

(b) Low temperature limit, high water cut out, backflow preventer, pressure relief valve

(c) Pressure relief valve, high temperature limit, water cutoff, back flow preventer

(d) Pressure relief, high temperature limit, low water cutout, back flow preventer -
CORRECT ANSWER -(a) Pressure relief valve, high temperature limit, low -water cutout,
backflow preventer

What is the normal operating pressure in a boiler?

(a) 2 to 5 psi
(b) 5 to 9 psi
(c) 12 to 15 psi
(d) 9 to 12 psi - CORRECT ANSWER -(c) 12 to 15 psi

In a two -story Victorian home with a boiler in the basement you find a pressure -reducing
valve set to 12 psi. Is there a possibility that his valve is set too low?

(a) Yes
(b) No - CORRECT ANSWER -(b) No Powered by TCPDF (www.tcpdf.org)
3 / 3

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller TIFFACADEMICS. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $15.49. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

67866 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$15.49
  • (0)
  Add to cart