100% satisfaction guarantee Immediately available after payment Both online and in PDF No strings attached
logo-home
TCFP Inspector's Class II Exam Questions and Answers (Rated A) $10.99   Add to cart

Exam (elaborations)

TCFP Inspector's Class II Exam Questions and Answers (Rated A)

 5 views  0 purchase
  • Course
  • TCFP Inspector\'s Class II
  • Institution
  • TCFP Inspector\'s Class II

Foam water system design and installation requirements are regulated by ___________. A. NFPA 13 B. NFPA 13R C. NFPA 25 D. NFPA 16 - ANSWER-NFPA 16 True or False, NFPA 72 allows only manual pull stations and water flow detection devices to be used on shunt systems. Fire detection devices are ...

[Show more]

Preview 4 out of 37  pages

  • March 29, 2024
  • 37
  • 2023/2024
  • Exam (elaborations)
  • Questions & answers
  • TCFP Inspector's Class II
  • TCFP Inspector's Class II
avatar-seller
IMORA
TCFP Inspector's Class II Exam
Questions and Answers (Rated A)

Which of the following are a type of sprinkler?
A) ESFR
B) EC
C) AF
D) A and B - ANSWER-A and B

Foam water system design and installation requirements are regulated by
___________.
A. NFPA 13
B. NFPA 13R
C. NFPA 25
D. NFPA 16 - ANSWER-NFPA 16

True or False, NFPA 72 allows only manual pull stations and water flow detection
devices to be used on shunt systems. Fire detection devices are not permitted. -
ANSWER-True

The fire alarm control panel (FACP) is essentially the _____ of the system. -
ANSWER-Brain

Heat sensing fire detector color coding has a RED extra high temperature rating of?
A.) 0-99f
B.)175-249f
C.) 325-399f
D.) 500-575f - ANSWER-325-399f

According to NFPA, travel distances to a manual pull station should not exceed
_____ feet.
A. 100
B. 200
C. 300
D. 400 - ANSWER-200

What color tag is used to indicate that an alarm system is impaired?
A. White
B. Yellow
C. Blue
D. Red - ANSWER-Red

About _____ % of fire deaths are attributed to smoke inhalation and not to burns.
A. 55%
B. 60%

,C. 65%
D. 70% - ANSWER-65%

When performing maintenance inspections of occupancies with alarm systems, the
first step will be to:
A) Check for green light indicating normal operation
B) Confirm monitoring status with alarm company
C) Confirm panel is locked and inaccessible to public
D) Confirm system has been tested by licensed alarm contractor and has a current
inspection tag - ANSWER-Confirm system has been tested by licensed alarm
contractor and has a current inspection tag

Most people are well aware of the dangers of fire but less aware of the dangers of
smoke inhalation. About ___% of of fire deaths are attributed to smoke inhalation
and not to burns.
A) 65
B) 80
C) 92
D) 75 - ANSWER-65

If required, pull stations should be placed within ___ feet of every exit.
a) 4
b) 5
c) 10
d) does not matter what distance, as long as it is not blocked - ANSWER-5

T or F: The development of clean-agent fire-extinguishing systems began in the late
1940s. - ANSWER-True

NFPA 10 has assigned a maximum travel distance of __ feet from the hazard to a
Class K extinguisher?
A) 30
B) 50
C) 75
D) 100 - ANSWER-30

If an extinguisher is suitable for use on a particular class of fire, the picture-symbol
background is what color?
A.) Red
B.) Light Blue
C.) Black
D.) Grey - ANSWER-Light Blue

Which one of the following is not considered a proper placement of a fire
extinguisher?
A. Visible and marked with legible signage.
B. Near Points of egress or ingress.
C. Sitting on top of a work bench with no mount.
D. Near formal paths of travel. - ANSWER-Sitting on top of a work bench with no
mount.

,Foam extinguishes a fire by one or more of the four following methods except:
A. Smothering
B. Seperating
C. Suppressing
D. Blanketing - ANSWER-Blanketing

In regards to carbon dioxide fire-extinguishing systems, total flooding systems are
designed to deliver at least ___ percent concentration of CO into and enclosed area.
A. 21
B. 19
C. 34
D. 15 - ANSWER-34

What is the fuel classification for combustible metals?
A. Class A
B. Class B
C. Class C
D. Class D - ANSWER-Class D

Most fire-extinguishing foam concentrates in use today are of the _____ type, which
means they must be proportioned with water and mixed with air (aerated) before
they can be used.
A. mechanical
B. electrical
C. slippery
D. bubbly - ANSWER-mechanical

A properly placed fire extinguisher will result in all of the following except:
A. Visible, signage not necessary
B. Not be blocked by storage or equipment
C. Near points of egress and ingress
D. Near normal paths of travel - ANSWER-Visible, signage not necessary

A dry chemical extinguishing system is used wherever rapid fire extinguishment is
required and where ________ of the burning material is unlikely.
A) exploding
B) oxidation
C) smothering
D) reignition - ANSWER-reignition

NFPA 10 establishes a Class B flammable liquid fire with depth at____
A. 1/2"
B. 1/4"
C. < 1/4"
D. > 1/2" - ANSWER-1/4"

What percentage of fire deaths is attributed to smoke inhalation?
A) 65%
B) 50%

, C) 42%
D) 15% - ANSWER-65%

True/False
A critical feature and limitation of special-agent fire-extinguishing systems is the
quality of agent available in the system. - ANSWER-False - "quantity"

High expansion foam fire extinguishing systems typically have the following
expansion rates:
A) 7:1 to 20:1
B) 20:1 to 200:1
C) 200:1 to 1,000:1
D) 1,000:1 to 2,500:1 - ANSWER-200:1 to 1,000:1

The most serious problem involving CO2 systems, especially total flooding systems,
is __________?
A. pre-activation
B. personnel safety
C. exploding actuating mechanisms
D. lack of nozzle lubrication - ANSWER-personnel safety

Which is not considered a foam expansion rate?
A. Low
B. Medium
C. High
D. Fast - ANSWER-Fast

In addition to foam concentrate and mechanical agitation, what other two elements
are necessary to produce high-quality fire fighting foam:
a) borosilicate ketone and muriatic acid
b) water and air
c) 3% hydrocarbon and a polar solvent
d) sodium bicarbonate and potassium chloride - ANSWER-water and air

Foam Fire-extinguishing systems extinguish the fire by one or more of the following
ways Except_____.
A. Smothering
B. Separating
C. Compressing
D. Cooling - ANSWER-Compressing

Class K extinguishing agents turn fats and oils into a soapy form that extinguishes
the fire through a process known as __________.
A. ozonification
B. ionization
C. saponification
D. lubrication - ANSWER-saponification

NFPA ______ is the Standard on Carbon Dioxide Extinguishing Systems.
a. NFPA 10

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller IMORA. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $10.99. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

73314 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$10.99
  • (0)
  Add to cart