NICET LEVEL III S-95 SUPERVISION OF FIRE ALARM SYSTEMS COMPLETE MATERIAL GUIDE 2024 an approved central station company is one that has been issued a valid certificate from ____________. - answer fdny a _________ is the open space that carries air between the ceilings and floor above. - answer plenum an _________ alarm is one which functioned as designed, but which department response is unneccessary. - answer unnecessary an _________ alarm is the result of improper installation, or maintenance. - answer unwarranted the new fire code was adopted in __________ and vastly changed the requirements for supervision of all fire alarm systems. - answer july 2008 duties that can be performed by an s -95 cof holder in clude ___________ only. - answer visual inspections only the primary purpose of a ____________ is to warn occupants and to transmit signals indication fire to the fdny. - answer fire alarm system the primary purpose of a ______________ is to process signals received from initiating devices and to activate appropriate signals. - answer fire alarm control panel a ___________ signal is initiated when a device indicates the presence of fire. - answer fire alarm a _________ signal indicates that a system or device b eing monitored is in an abnormal state. - answer supervisory a __________ signal indicates that the alarm system, transmitter, or communications path is wholly or partially out of service. - answer trouble routine handling of trouble signals should take a ma ximum of ___________ minutes from receipt of trouble signal by central station until initial investigation by telephone. - answer four the fdny is not dispatched to respond to _________ or ________ signals. - answer supervisory, trouble do not silence the bu ilding ___________ and ________ device until the fire alarm condition is verified by fdny personnel. - answer audible, visual smoke detectors must be cleaned at least _____________ by an s -78, s -
97, t-97, or s -98 cof holder. - answer once every six months. any abnormal conditions must be investigated and noted in the ___________. - answer logbook the fire alarm primary power source shall be generated electric power not exceeding ____________ volts. - answer 277/480 ________ shall not be a substitute for connect ion to a secondary power source. - answer batteries
The benefits of buying summaries with Stuvia:
Guaranteed quality through customer reviews
Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.
Quick and easy check-out
You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.
Focus on what matters
Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!
Frequently asked questions
What do I get when I buy this document?
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
Satisfaction guarantee: how does it work?
Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.
Who am I buying these notes from?
Stuvia is a marketplace, so you are not buying this document from us, but from seller smartzone. Stuvia facilitates payment to the seller.
Will I be stuck with a subscription?
No, you only buy these notes for $11.99. You're not tied to anything after your purchase.