Florida Home Inspector Exam Questions With Correct And Complete Solutions Service entrace conductors run from the service drop to the service box or service panel. True or False? True The service size is determined by the amperage and the voltage ratings of the service. True Is the service d...

[Show more]

Preview 4 out of 115  pages

  • January 21, 2024
  • 115
  • 2023/2024
  • Exam (elaborations)
  • Questions & answers
avatar-seller
Florida Home Inspector Exam Questions With
Correct And Complete Solutions
Service entrace conductors run from the service drop to the service box or
service panel. True or False?
True
The service size is determined by the amperage and the voltage ratings of the
service.
True
Is the service drop overhead or underground?
Overhead
Are service laterals overhead or underground?
Underground
The drip loop is typically part of the service drop. True or False?
False
The wire size for the service drop must be the same as the wire size for the
service entrance conductors. True or False?
False
How many wires would you typically find in a 240-volt service drop?
3
What would 4 wires mean?
3-phase electricity
What would 2 wires usually mean?
120 volt service
List 7 common problems with service drops.
1. Overhead wires too low.
2. Damaged or frayed wires.
3. Trees or vines interfering with wires.
4. Wires too close to doors or windows.

,5. Wires not well-secured to the house.
6. Poor connection between service drop and service entrance.
7. Inadequate clearance from roofs.
List clearances above ground, swimming pools, and roofs.
above roadway--18 ft.
above driveway--12 ft.
above flat roof--8 to 10 ft.
above sloped roof--18 inches
away from water in swimming pool--22.5 ft
3 ft. above sloped roof with pitch > 4 in 12
above walkway--10 ft.
The service entrance conductors run from the _________ to the ___________.
service drop to service box
All service entrance conductors must be in conduit. True or False?
False
All service entrance conductors must be attached above roof level. True or
False?
False
The drip loop should be as close to the roof as possible. True or False?
False
List 10 common problems with service entrance conductors.
1. No drip loop
2. No mast head
3. Mast head not weather tight.
4. Mast or conduit bent.
5. Mast or conduit rusted.
6. Mast rotted (if wood).
7. Mast conduit or cable not well secured.
8. Mast conduit or cable not weather tight.
9. Conduit or cable not well sealed at house/wall penetration.
10. Cable frayed, damaged, or covered by siding.

,List 4 common areas of water penetration into service entrances.
1. conduit joints
2. mast head
3. roof flashing
4. meter base
5. house entry
List 2 functions of the drip loop.
1. Prevents water entry into the conduit or service entrance conductors.
2. Shows that the service drop wires are not straining the splices.
Roughly 999 out of 1000 houses have _________ volts available.
240
Roughly 999 out of 1000 houses have __________ service entrance wires.
3
Load calculations are part of a home inspection.
False
Implications of an undersized service include:
a. shock hazard
b. fire hazard
c. shock and fire hazard
d. melting insulation
e. nuisance tripping of the main fuses and breakers
e.
What is the largest single-phase service that you are likely to find in a home?
400 amps
What size copper wire would you expect to find on the service entrance for:
a. 60-amp service
b. 100-amp service
c. 200-amp service
a. 6 gauge
b. 4 gauge
c. 2-0 gauge

, Which of the following is a reliable way to identify the service size?
a. the size of the service drop wires
b. the distribution panel rating
c. the service box rating
d. the service entrance conductor
e. the service entrance conduit size
d.
Aluminum is an acceptable service entrance conductor material. True or False?
True
A fused 200-amp service has two 100-amp fuses in the service box. True or
False?
False
If you can't read the size of the fuses in the service box, you should remove them
to try to get a better look. True or False?
False
Which of the following is a safety issue:
a. The main fuses have a lower rating than the service entrance wire.
b. The main fuses have a higher rating than the service entrance wire.
c. The service box has a higher rating than the service entrance wires.
d. The service box has the same rating as the service entrance wires.
e. The distribution panel has a larger rating than the service entrance wires.
b
The service box can be inside, outside, or in the garage. True or False?
True
There can be up to 10 throws to disconnect all the electricity in the house. True or
False?
False
The service box may stand alone or may be combined with the distribution panel.
True or False?
True
List common conditions you might find in a service box.

The benefits of buying summaries with Stuvia:

Guaranteed quality through customer reviews

Guaranteed quality through customer reviews

Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.

Quick and easy check-out

Quick and easy check-out

You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.

Focus on what matters

Focus on what matters

Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!

Frequently asked questions

What do I get when I buy this document?

You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.

Satisfaction guarantee: how does it work?

Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.

Who am I buying these notes from?

Stuvia is a marketplace, so you are not buying this document from us, but from seller NurseAdvocate. Stuvia facilitates payment to the seller.

Will I be stuck with a subscription?

No, you only buy these notes for $12.49. You're not tied to anything after your purchase.

Can Stuvia be trusted?

4.6 stars on Google & Trustpilot (+1000 reviews)

80202 documents were sold in the last 30 days

Founded in 2010, the go-to place to buy study notes for 14 years now

Start selling
$12.49
  • (0)
  Add to cart