EPA 608 TYPE 1 TEST ACTUAL EXAM 200 QUESTIONS AND CORRECT DETAILED ANSWERS (VERIFIED ANSWERS) |ALREADY GRADED A+
6 views 0 purchase
Course
EPA 608 TYPE 1
Institution
EPA 608 TYPE 1
EPA 608 TYPE 1 TEST ACTUAL EXAM 200
QUESTIONS AND CORRECT DETAILED ANSWERS
(VERIFIED ANSWERS) |ALREADY GRADED A+
EPA 608 TYPE 1 TEST ACTUAL EXAM 200
QUESTIONS AND CORRECT DETAILED ANSWERS
(VERIFIED ANSWERS) |ALREADY GRADED A+
EPA 608 TYPE 1 TEST 2023-2024 ACTUAL EXAM 200
QUESTIONS AND CORRECT DETAILED ANSWERS
(VERIFIED ANSWERS) |ALREADY GRADED A+
which of the following is not a type 1 appliance - ANSWER-an mvac like
system that holds three pounds of R-12
When R-500 is recovered from an appliance, it: - ANSWER-must be
recovered into its own recovery vessel (or a recovery cylinder that already
contains some R-500).
when you connect your service manifold to check system pressures it's
always a good idea to - ANSWER-use equipment such as hard hand
valves or self sealing hoses to minimizes any release
The Epa requires that all appliances must be equipped with a service
aperture or other device that is used when adding or removing refrigerant
from the appliance. Form small appliances, this service port typically is -
ANSWER-a small piece of tubing called a process tube
Anyone who recovers refrigerant during the maintenance, service or repair
of small appliances must be certified as either a Universal Technician or a:
- ANSWER-type ! technician
EPA regulations require the capture of at least 80% of the refrigerant from
a small appliance with an non operating compressor is the tech is using: -
ANSWER-either type of recovery unit
when using a passive recovery method on an appliance with an operating
compressor you should run the compressor - ANSWER-and recover the
refrigerant form the high side
, EPA 608 TYPE 1 TEST 2023-2024 ACTUAL EXAM 200
QUESTIONS AND CORRECT DETAILED ANSWERS
(VERIFIED ANSWERS) |ALREADY GRADED A+
a passive system dependent recovery device for small appliances -
ANSWER-captures refrigerant in a non pressurized container
The sale of CFC and HCFC refrigerants is: - ANSWER-restricted to
technicians who are EPA certified in refrigerant recovery
Which of the refrigerants listed below should be recovered with current
EPA approved recovery devices - ANSWER-none of the above
when servicing a small appliance with a leak - ANSWER-it is not mandatory
to repair the leak but do so whenever
for which of the following refrigeraton systems/ appliances would it be
permissible to use a passive recovery device for refrigerant recovery -
ANSWER-a domestic refrigerator
When using any equipment or servicing any system that has schraeder
valves, it is "critical" to: - ANSWER-inspect the Schrader valve core for
bends and breakage, replace any damaged Schrader valve core to prevent
leakage, cap the Schrader ports to prevent accidental depression of the
valve core
If R-12 or R-22 are exposed to high temperatures, (from open flames or
glowing hot metal surfaces for example), these refrigerants can decompose
to form: - ANSWER-hydrochloric and hydrofluoric acids
, EPA 608 TYPE 1 TEST 2023-2024 ACTUAL EXAM 200
QUESTIONS AND CORRECT DETAILED ANSWERS
(VERIFIED ANSWERS) |ALREADY GRADED A+
When using a graduated charging cylinder, any refrigerant that is vented
from the charging cylinder: - ANSWER-must be recovered
A standard vacuum pump designed specifically for evacuation and
dehydration can: - ANSWER-never be used as a recovery device in
combination with a pressurized container
the epa section 608 certification must be renewed every - ANSWER-the
epa certification has no expiration date
Prior to shipping any used refrigerant it is necessary to: - ANSWER-
properly label the refrigerant container, properly complete shipping
paperwork, check that the refrigerant container meets department of
transportation standards
A refrigerant that can be used as a direct service drop in subsitute for R-12
in a small appliance is: - ANSWER-none of the above
after installing and opening a piercing access valve if the system pressure
is _______ do not begin the recovery procedure - ANSWER-0 psig
when using ________ it is essential to take extra measures to help release
trapped refrigerant from the compressor oil - ANSWER-passive system
dependent recovery devices on a small appliances with a non operating
compressor
it is an EPA regulation that any person who opens an appliance for
maintenance, service or repair must have at least one self contained
The benefits of buying summaries with Stuvia:
Guaranteed quality through customer reviews
Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.
Quick and easy check-out
You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.
Focus on what matters
Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!
Frequently asked questions
What do I get when I buy this document?
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
Satisfaction guarantee: how does it work?
Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.
Who am I buying these notes from?
Stuvia is a marketplace, so you are not buying this document from us, but from seller erickarimi. Stuvia facilitates payment to the seller.
Will I be stuck with a subscription?
No, you only buy these notes for $22.49. You're not tied to anything after your purchase.