Nursing PN 3 EXAM 2 FINAL STUDY GUIDE.Cardiac
Normal cardiac output- Normal cardiac output is 60-100 beats per minute. If below 60 is brady
cardia and the patient is at risk for poor perfusion. Cardiac output is defined as the amount of
blood pumped from the left ventricle each minute.
Remember...
Cardiac
Normal cardiac output- Normal cardiac output is 60-100 beats per minute. If below 60 is brady
cardia and the patient is at risk for poor perfusion. Cardiac output is defined as the amount of
blood pumped from the left ventricle each minute.
Remember that arrhythmia is a deviation from a normal rhythm and a dysrhythmia is a
disturbance in the normal rhythm.
Medications for:
contractility, maintaining normal blood pressure, various tachycardias, bradycardias,
different degrees of AV blocks, and arrhythmias
PHARM
Class 1- Sodium channel blockers- electrical pulses will become slow. Used for
TACHYARHYTHMIAS
Class II- Beta Blockers. Beta receptors are blocked. Used for tach arrhythmias
Class III- potassium channel blockers. Amiodarone. Used for V tach and V fib
Class for- calcium channel blockers- diltiazem, arabamil? Given to slow ventricular rate in a fib
and supra ventricular tachycardia.
Adenosine/ Digoxin- Adenosine has very short half life and is given IV push and primarily used
to stop supra ventricular tach
Digoxin- will slow conduction through the AV node. A fib and A flutter
Heparin is given for A fib- will cause pooling that will lead to clotting and can cause PE or
stroke.
Cardiac rhythm interpretations
P wave: represents atrial contraction depolarization; small, rounded and upright (in Lead II). Are they
present before every QRS and do they look the same?
PR Interval (PRI): time it takes the impulse to travel from the SA node to the bundle branches. It should
measure 0.12-0.20 seconds. Starts at P wave and ends at the beginning of the ventricular contraction.
QRS Interval: represents ventricular depolarization (contraction); it should measure 0.04-0.10 seconds.
T wave: represents ventricular repolarization (relax). Monitor for changes in amplitude or configuration.
QT Interval: represents the amount of time it takes for ventricular depolarization and repolarization.
Measurement will depend on heart rate but it is usually 0.40 to 0.44 seconds.
U wave: Rare/ uncommon. Resting of perkinje fibers.
ST segment: Starting with the ventricular contraction to before the T wave. THIS IS WHERE MI CAN BE
DETECTED.
Depolarization is contraction. Results in action potential.
Repolarization is relaxation
, If AV conduction is not normal will see cardiac block.
PLEASE SEE NOTES… TRIED TO EXPLAIN BUT IT WAS DIFFICULT.
6 Seconds = 30 small squares. Count for atrial or ventricular rate is to count 30 large squares (P
Wave for Atrium contraction) (R wave for ventricular waves).
Example:
If four squares are counted in P wave then take 4x10= 40 and will give atrial rate.
External vs internal pacemaker- EXTERNAL is done in EMERGENT situations!! Is used until
permanent pacemaker can be placed.
Internal pacemaker is either synchronous (demand) or asynchronous (fixed rate)
When a pacing stimulus is delivered to the heart, a spike (or pacemaker
artifact) is seen on the monitor or ECG strip. The spike should be followed by
evidence of depolarization (i.e., a P wave, indicating atrial depolarization, or
a QRS complex, indicating ventricular depolarization). This pattern is referred
The benefits of buying summaries with Stuvia:
Guaranteed quality through customer reviews
Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.
Quick and easy check-out
You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.
Focus on what matters
Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!
Frequently asked questions
What do I get when I buy this document?
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
Satisfaction guarantee: how does it work?
Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.
Who am I buying these notes from?
Stuvia is a marketplace, so you are not buying this document from us, but from seller StudyConnect. Stuvia facilitates payment to the seller.
Will I be stuck with a subscription?
No, you only buy these notes for $15.49. You're not tied to anything after your purchase.