Package deal
ACI Concrete Bundled Exams Questions and Answers Multiple Versions (2024/2025) (Complete and Accurate)
ACI Concrete Bundled Exams Questions and Answers Multiple Versions (2024/2025) (Complete and Accurate)
[Show more]ACI Concrete Bundled Exams Questions and Answers Multiple Versions (2024/2025) (Complete and Accurate)
[Show more]ACI ASTM C138 Latest Version with 
 
Complete Solutions 
 
ASTM C138 is used for what test method for Density(unit weight), Yield, and Air 
Content(gravimetric) of concrete 
 
A lower density may indicate what 1)materials have changed[lower specific gravity], 
2)higher water content, 3)higher air co...
Preview 2 out of 6 pages
Add to cartACI ASTM C138 Latest Version with 
 
Complete Solutions 
 
ASTM C138 is used for what test method for Density(unit weight), Yield, and Air 
Content(gravimetric) of concrete 
 
A lower density may indicate what 1)materials have changed[lower specific gravity], 
2)higher water content, 3)higher air co...
ACI 318-14 Concrete Code Questions 
 
and Answers 100% Pass 
 
1 - What is the minimum thickness of concrete bearing walls? 
 
1 - 5 1⁄2 inches 
2 - 6 inches 
3 - 7 1⁄2 inches 
 
4 - 8 inches 1 - 5 1⁄2 inches 
 
2 - What is the maximum amount of fly ash that can be added to concrete exposed to...
Preview 2 out of 11 pages
Add to cartACI 318-14 Concrete Code Questions 
 
and Answers 100% Pass 
 
1 - What is the minimum thickness of concrete bearing walls? 
 
1 - 5 1⁄2 inches 
2 - 6 inches 
3 - 7 1⁄2 inches 
 
4 - 8 inches 1 - 5 1⁄2 inches 
 
2 - What is the maximum amount of fly ash that can be added to concrete exposed to...
Concrete Flatwork Tech and Flatwork 
Finisher (3rd Ed.) 100% Pass 
 
(Ch. 1, #1) It is important that the _______ _______ read and understand project specifications 
finishing foreman 
 
(Ch. 1, #2) If the crew can place and finish 100yd^3 (m^3) of concrete per hour, the producer's 
rate should be ...
Preview 4 out of 33 pages
Add to cartConcrete Flatwork Tech and Flatwork 
Finisher (3rd Ed.) 100% Pass 
 
(Ch. 1, #1) It is important that the _______ _______ read and understand project specifications 
finishing foreman 
 
(Ch. 1, #2) If the crew can place and finish 100yd^3 (m^3) of concrete per hour, the producer's 
rate should be ...
ACI Concrete Strength Testing 
Technician Sample Written Exam 
Questions with Complete Solutions 
 
These procedures for capping enable concrete cylinders and cores to meet the standard's 
requirements for: a) planeness b)strength c) perpendicularity d) B and C e) A and C E) 
 
The strength of th...
Preview 1 out of 2 pages
Add to cartACI Concrete Strength Testing 
Technician Sample Written Exam 
Questions with Complete Solutions 
 
These procedures for capping enable concrete cylinders and cores to meet the standard's 
requirements for: a) planeness b)strength c) perpendicularity d) B and C e) A and C E) 
 
The strength of th...
ACI Concrete Field Testing Technician- 
Grade I Questions and Answers Already 
 
Passed 
 
The sensor of the temperature measuring device shall be submerged a minimum of _____ in. 
[_____mm] into the freshly mixed concrete. 3 in. [75 mm] 
 
The temperature measuring device shall have a capacity of m...
Preview 3 out of 23 pages
Add to cartACI Concrete Field Testing Technician- 
Grade I Questions and Answers Already 
 
Passed 
 
The sensor of the temperature measuring device shall be submerged a minimum of _____ in. 
[_____mm] into the freshly mixed concrete. 3 in. [75 mm] 
 
The temperature measuring device shall have a capacity of m...
ACI Concrete- Section 4 Questions and 
 
Answers Graded A+ 
 
The diameter of the tamping rod used in this test method is ________. 16 mm (5/8") + or - 2 
mm (1/16") 
 
What is the required shape of the tamping end of the rod Rounded to Hemispherical tip 
 
What is the required minimum frequency o...
Preview 2 out of 5 pages
Add to cartACI Concrete- Section 4 Questions and 
 
Answers Graded A+ 
 
The diameter of the tamping rod used in this test method is ________. 16 mm (5/8") + or - 2 
mm (1/16") 
 
What is the required shape of the tamping end of the rod Rounded to Hemispherical tip 
 
What is the required minimum frequency o...
ACI Concrete Strength Technician 
Questions and Answers Already Passed 
 
What is ASTM C1231? Standard Practice for use of Unbonded Caps in determination of 
compressive strength of hardened cylindrical concrete specimens 
 
(C1231) The height (cavity) of the metal retaining ring must be (25 +/- 3mm...
Preview 3 out of 16 pages
Add to cartACI Concrete Strength Technician 
Questions and Answers Already Passed 
 
What is ASTM C1231? Standard Practice for use of Unbonded Caps in determination of 
compressive strength of hardened cylindrical concrete specimens 
 
(C1231) The height (cavity) of the metal retaining ring must be (25 +/- 3mm...
ACI Written Exam Questions and 
Answers Already Passed 
 
The sensor of the temperature measureing device shall be submerged a minimum of ____ in 
3 (75mm) 
 
The temperature measureing device shall have a capacity of measuring temperature of freshly 
mixed conrcrete to +-_____ degrees F throught a ...
Preview 3 out of 20 pages
Add to cartACI Written Exam Questions and 
Answers Already Passed 
 
The sensor of the temperature measureing device shall be submerged a minimum of ____ in 
3 (75mm) 
 
The temperature measureing device shall have a capacity of measuring temperature of freshly 
mixed conrcrete to +-_____ degrees F throught a ...
ACI Flatwork Questions and Answers 
 
Already Passed 
 
It is important that the ____________ __________ read and understand project specifications. 
finisher foreman 
 
If the crew can place and finish 100 yd3 of concrete per hour, the producer's delivery rate should 
be about _____ yd3 per hour. ...
Preview 3 out of 16 pages
Add to cartACI Flatwork Questions and Answers 
 
Already Passed 
 
It is important that the ____________ __________ read and understand project specifications. 
finisher foreman 
 
If the crew can place and finish 100 yd3 of concrete per hour, the producer's delivery rate should 
be about _____ yd3 per hour. ...
ACI Certification - Concrete Field Testing 
Technician - Grade 1 - Test Sample 
Written Exam Questions - CP-1(17) 100% 
 
Correct 
 
The Method of determining air content of concrete containing lightweight aggregate is the 
pressure method. True or False? False 
 
When making a test cylinder from co...
Preview 1 out of 4 pages
Add to cartACI Certification - Concrete Field Testing 
Technician - Grade 1 - Test Sample 
Written Exam Questions - CP-1(17) 100% 
 
Correct 
 
The Method of determining air content of concrete containing lightweight aggregate is the 
pressure method. True or False? False 
 
When making a test cylinder from co...
ACI Strength Exam Study Guide 
Questions with Certified Solutions 
 
Name the two allowable materials with with concrete cylinders may be capped with. I. High- 
strength gypsum 
 
II. Sulfur mortar 
III. Neat cement paste 
 
Name the three materials with with cylinders may be capped against. I. Glas...
Preview 3 out of 28 pages
Add to cartACI Strength Exam Study Guide 
Questions with Certified Solutions 
 
Name the two allowable materials with with concrete cylinders may be capped with. I. High- 
strength gypsum 
 
II. Sulfur mortar 
III. Neat cement paste 
 
Name the three materials with with cylinders may be capped against. I. Glas...
ACI Concrete Strength Testing 
Technician CP-19 (14) Questions and 
 
Answers Already Passed 
 
These procedures for capping enable concrete cylinders and cores to meet the standard's 
requirements for ________ and _________. Planeness, perpendicularity 
 
Equipment needed for the capping process...
Preview 3 out of 15 pages
Add to cartACI Concrete Strength Testing 
Technician CP-19 (14) Questions and 
 
Answers Already Passed 
 
These procedures for capping enable concrete cylinders and cores to meet the standard's 
requirements for ________ and _________. Planeness, perpendicularity 
 
Equipment needed for the capping process...
ACI Concrete Field Testing Technician - 
Grade I Questions and Answers 100% 
 
Pass 
 
The end of the temperature sensing portion of the temperature measuring device is submerged a 
minimum of __mm [__in.] into the freshly mixed concrete. 77mm /3in. 
 
The temperature measuring device shall be capab...
Preview 2 out of 10 pages
Add to cartACI Concrete Field Testing Technician - 
Grade I Questions and Answers 100% 
 
Pass 
 
The end of the temperature sensing portion of the temperature measuring device is submerged a 
minimum of __mm [__in.] into the freshly mixed concrete. 77mm /3in. 
 
The temperature measuring device shall be capab...
ACI Concrete Field Testing Technician 
Grade 1 Study Guide Latest Update 
 
Rated A+ 
 
ASTM C31 / C31M-06 Standard Practice for Making, Curing, Protecting & Transporting 
Test Specimens in the Field Conditions. 
 
ASTM C1064 /C1064M-05 Standard Test Method for Temperature of Freshly Mixed 
Hydrauli...
Preview 2 out of 15 pages
Add to cartACI Concrete Field Testing Technician 
Grade 1 Study Guide Latest Update 
 
Rated A+ 
 
ASTM C31 / C31M-06 Standard Practice for Making, Curing, Protecting & Transporting 
Test Specimens in the Field Conditions. 
 
ASTM C1064 /C1064M-05 Standard Test Method for Temperature of Freshly Mixed 
Hydrauli...
ACI Test Questions and Answers 
(2024/2025) (Complete and Accurate) 
 
The total time allowed between obtaining the first and final portions of a composite sample is 
15 minutes 
 
When it is necessary to wet sieve the concrete sample, wet sieving should be performed after the 
individual samples ar...
Preview 2 out of 13 pages
Add to cartACI Test Questions and Answers 
(2024/2025) (Complete and Accurate) 
 
The total time allowed between obtaining the first and final portions of a composite sample is 
15 minutes 
 
When it is necessary to wet sieve the concrete sample, wet sieving should be performed after the 
individual samples ar...
ACI Concrete Field Testing Technician- 
Grade I Latest Update Graded A+ 
 
The sensor of the temperature measuring device shall be submerged a minimum of _____ in. 
[_____mm] into the freshly mixed concrete. 3 in. [75 mm] 
 
The temperature measuring device shall have a capacity of measuring tempera...
Preview 3 out of 23 pages
Add to cartACI Concrete Field Testing Technician- 
Grade I Latest Update Graded A+ 
 
The sensor of the temperature measuring device shall be submerged a minimum of _____ in. 
[_____mm] into the freshly mixed concrete. 3 in. [75 mm] 
 
The temperature measuring device shall have a capacity of measuring tempera...
ACI Certification- Concrete Field Testing 
Technician Grade 1 CP-1 (12) Latest 2024 
 
Graded A+ 
 
ASTM C1064 Standard Test Method For Temperature of Freshly Mixed Hydraulic-Cement 
Concrete 
 
The sensor of the temperature measuring device shall be submerged a minimum of ______ 
inches into the fr...
Preview 3 out of 27 pages
Add to cartACI Certification- Concrete Field Testing 
Technician Grade 1 CP-1 (12) Latest 2024 
 
Graded A+ 
 
ASTM C1064 Standard Test Method For Temperature of Freshly Mixed Hydraulic-Cement 
Concrete 
 
The sensor of the temperature measuring device shall be submerged a minimum of ______ 
inches into the fr...
Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.
You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.
Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.
Stuvia is a marketplace, so you are not buying this document from us, but from seller StellarScores. Stuvia facilitates payment to the seller.
No, you only buy these notes for $25.49. You're not tied to anything after your purchase.
4.6 stars on Google & Trustpilot (+1000 reviews)
67163 documents were sold in the last 30 days
Founded in 2010, the go-to place to buy study notes for 14 years now