Package deal
NICET LEVELS I, II, III PACKAGE SOLUTION GRADED A
NICET LEVELS I, II, III PACKAGE SOLUTION GRADED A
[Show more]NICET LEVELS I, II, III PACKAGE SOLUTION GRADED A
[Show more]NICET LEVEL 1 HIGHWAY CONSTRUCTION ALREADY 
GRADED A+ 
Acceptance The written acceptance by the Department of the Work. 
acceptance testing 
the Contract 
actual cost 
Testing conducted by the Department to measure the degree of compliance to 
The computed cost using calculations provided 
a...
Preview 2 out of 8 pages
Add to cartNICET LEVEL 1 HIGHWAY CONSTRUCTION ALREADY 
GRADED A+ 
Acceptance The written acceptance by the Department of the Work. 
acceptance testing 
the Contract 
actual cost 
Testing conducted by the Department to measure the degree of compliance to 
The computed cost using calculations provided 
a...
NICET LEVEL III WATER BASED LAYOUT 2024 
General Conditions 
•contract 
•specifications 
•contract drawings 
General Conditions 
What is not included in the technical specification? 
Bid documents include? 
Codes, standards, Authority Having Jurisdiction (AHJ), clean-up, safety ...
Preview 3 out of 17 pages
Add to cartNICET LEVEL III WATER BASED LAYOUT 2024 
General Conditions 
•contract 
•specifications 
•contract drawings 
General Conditions 
What is not included in the technical specification? 
Bid documents include? 
Codes, standards, Authority Having Jurisdiction (AHJ), clean-up, safety ...
Nicet Level 2: Earth Work Already Rated A+ 
What does the Sand Cone Method Determine? 
In-place density of soil and aggregates 
Mass for sand cone test should be recorded to nearest? 
Sand cone test can also be used to determine? 
0.01lbs 
Moisture content and dry mass of excavated soil 
H...
Preview 2 out of 7 pages
Add to cartNicet Level 2: Earth Work Already Rated A+ 
What does the Sand Cone Method Determine? 
In-place density of soil and aggregates 
Mass for sand cone test should be recorded to nearest? 
Sand cone test can also be used to determine? 
0.01lbs 
Moisture content and dry mass of excavated soil 
H...
NETTCP Training Already Graded A+ 2024 
Quality assurance is defined as 
plans or action taken by an agency that provides confidence that a 
product or service with be satisfactory/adequate 
I-15 
A Quality Assurance program serves as 
Assurance implementation 
I-18 
the framework necess...
Preview 2 out of 10 pages
Add to cartNETTCP Training Already Graded A+ 2024 
Quality assurance is defined as 
plans or action taken by an agency that provides confidence that a 
product or service with be satisfactory/adequate 
I-15 
A Quality Assurance program serves as 
Assurance implementation 
I-18 
the framework necess...
NICET Level 2 Questions Already Graded A+ 2024 
4 Consider a room which is 40' square. How many 15cd wall mounted strobes are required to 
adequately cover this space? 
Annually 
What is the testing frequency of a strobe? 
15 In a corridor application, visible appliances shall be rated not les...
Preview 1 out of 4 pages
Add to cartNICET Level 2 Questions Already Graded A+ 2024 
4 Consider a room which is 40' square. How many 15cd wall mounted strobes are required to 
adequately cover this space? 
Annually 
What is the testing frequency of a strobe? 
15 In a corridor application, visible appliances shall be rated not les...
Nicet Level 1 Questions And Answers 2024 
rises or falls over 3 inches (NFPA 72, Table 14.4.3.2 17 (j) (4) 
When testing a water level 
supervisory switch serving a pressure tank a signal shall indicate if the water level 
_____________from the required level 
the visible appliance (Nfpa 72 1...
Preview 1 out of 2 pages
Add to cartNicet Level 1 Questions And Answers 2024 
rises or falls over 3 inches (NFPA 72, Table 14.4.3.2 17 (j) (4) 
When testing a water level 
supervisory switch serving a pressure tank a signal shall indicate if the water level 
_____________from the required level 
the visible appliance (Nfpa 72 1...
NICET LEVEL 1 All Answers Rated A+ 
4 wires 
what is the maximum number of 14 AWG RHH conductors which can be installed in 1/2 
rigid metal conduit? 
3.5'-48" to the actuator 
pull station? 
1 flash per second 
Which of the following would be an appropriate mounting height for a 
What is t...
Preview 2 out of 8 pages
Add to cartNICET LEVEL 1 All Answers Rated A+ 
4 wires 
what is the maximum number of 14 AWG RHH conductors which can be installed in 1/2 
rigid metal conduit? 
3.5'-48" to the actuator 
pull station? 
1 flash per second 
Which of the following would be an appropriate mounting height for a 
What is t...
NICET level 1 Study Guide Questions And Answers All Correct 
When testing a water level supervisory switch serving a pressure tank a signal shall indicate if the 
water level _____________from the required level 
(NFPA 72, Table 14.4.3.2 17 (j) (4) 
rises or falls over 3 inches 
If combinatio...
Preview 3 out of 16 pages
Add to cartNICET level 1 Study Guide Questions And Answers All Correct 
When testing a water level supervisory switch serving a pressure tank a signal shall indicate if the 
water level _____________from the required level 
(NFPA 72, Table 14.4.3.2 17 (j) (4) 
rises or falls over 3 inches 
If combinatio...
NICET Level 1 Water-based Systems Guaranteed Success 
What is a purpose of a control valve 
Control Flow to water based fire protection system 
The gauge on the quick opening device shall indicate _____ as compared to the gauge on the system 
side of the dry pipe valve? 
the same pressure 
V...
Preview 2 out of 5 pages
Add to cartNICET Level 1 Water-based Systems Guaranteed Success 
What is a purpose of a control valve 
Control Flow to water based fire protection system 
The gauge on the quick opening device shall indicate _____ as compared to the gauge on the system 
side of the dry pipe valve? 
the same pressure 
V...
NICET Fire Alarm Level 1 Graded A+ 
When a device is inaccessible due to excessive height, such as an atrium, what it the maximum 
interval for testing? 
18 months 
When installing a wall-mounted fire telephone appliance to the public, what is the acceptable 
maximum mounting height from the ...
Preview 2 out of 9 pages
Add to cartNICET Fire Alarm Level 1 Graded A+ 
When a device is inaccessible due to excessive height, such as an atrium, what it the maximum 
interval for testing? 
18 months 
When installing a wall-mounted fire telephone appliance to the public, what is the acceptable 
maximum mounting height from the ...
NICET 2 All Answers Correct 
Where located above floor (within 2.1m or 7ft.) cables shall be securely fastened at intervals of? 
not more than 18 inches 
Which cable types can be installed in fireproof riser shafts? 
FPLP, FPLR, and FPL 
How many THHN conductors can fit in a 3/4 size Rigid PVC...
Preview 2 out of 9 pages
Add to cartNICET 2 All Answers Correct 
Where located above floor (within 2.1m or 7ft.) cables shall be securely fastened at intervals of? 
not more than 18 inches 
Which cable types can be installed in fireproof riser shafts? 
FPLP, FPLR, and FPL 
How many THHN conductors can fit in a 3/4 size Rigid PVC...
NICET Level 1 ITM Of Water-Based Systems 2024 
Who is responsible for the inspection, testing, maintenance and impairment of a water based fire 
protection system? 
The Property owner or designated representative 
Who's responsibility is it to provide accessibility to components of a water ba...
Preview 2 out of 9 pages
Add to cartNICET Level 1 ITM Of Water-Based Systems 2024 
Who is responsible for the inspection, testing, maintenance and impairment of a water based fire 
protection system? 
The Property owner or designated representative 
Who's responsibility is it to provide accessibility to components of a water ba...
NICET FAS Top 100 Q&A 2024 
Standby power 24 hours 1 
Alarm Power 5 minutes 
MNS Power 15 minutes 
household alarm power 4 minutes 1 
battery safety margin 
20 % 
switch to secondary power 
alarm turn on time 
10 seconds 2 
10 seconds 1 
supervisory signal time 
trouble signal time 
90 ...
Preview 2 out of 6 pages
Add to cartNICET FAS Top 100 Q&A 2024 
Standby power 24 hours 1 
Alarm Power 5 minutes 
MNS Power 15 minutes 
household alarm power 4 minutes 1 
battery safety margin 
20 % 
switch to secondary power 
alarm turn on time 
10 seconds 2 
10 seconds 1 
supervisory signal time 
trouble signal time 
90 ...
NICET Level 2 ITM of Water Based Systems Already Graded A+ 
When placing a LOTO on a system, how many locks should be applied? 
personnel working on the system. 
As many locks as their are 
A ladder must be able to support ____ times the weight of the expected load 
3.3 
It is acceptable to ...
Preview 2 out of 13 pages
Add to cartNICET Level 2 ITM of Water Based Systems Already Graded A+ 
When placing a LOTO on a system, how many locks should be applied? 
personnel working on the system. 
As many locks as their are 
A ladder must be able to support ____ times the weight of the expected load 
3.3 
It is acceptable to ...
NICET Level 1 - Water Based Layout Already Rated A+ 
Toggle hangers shall be permitted only for the support of pipe __________ inches or smaller in size 
under ceilings of hollow tile or metal lath and plaster. 
1 2/2 in. (ref. NFPA 13 2016 Sec. 9.2.1.1.2. 
While conducting a flow test, the chos...
Preview 2 out of 15 pages
Add to cartNICET Level 1 - Water Based Layout Already Rated A+ 
Toggle hangers shall be permitted only for the support of pipe __________ inches or smaller in size 
under ceilings of hollow tile or metal lath and plaster. 
1 2/2 in. (ref. NFPA 13 2016 Sec. 9.2.1.1.2. 
While conducting a flow test, the chos...
NICET Level 1 Fire Inspection & Testing of Water Based Fire 
Protection Systems Already Rated A+ 
25NFPA Chapter One 
set out the administration or scope of NFPA 25 
Where can the referenced publication that are used to create NFPA 25 be found? 
What is the defination of AHJ 
Chapter 2 ...
Preview 2 out of 5 pages
Add to cartNICET Level 1 Fire Inspection & Testing of Water Based Fire 
Protection Systems Already Rated A+ 
25NFPA Chapter One 
set out the administration or scope of NFPA 25 
Where can the referenced publication that are used to create NFPA 25 be found? 
What is the defination of AHJ 
Chapter 2 ...
NICET Fire Alarm Systems Level 1 Exam Verified Solutions 
if a combination audible/visible appliances are installed, the location of the installed appliance shall 
be determined by the requirements of 
the visible appliance 
what is the maximum number of 12-gaugeTHHN conductors that can be inst...
Preview 1 out of 3 pages
Add to cartNICET Fire Alarm Systems Level 1 Exam Verified Solutions 
if a combination audible/visible appliances are installed, the location of the installed appliance shall 
be determined by the requirements of 
the visible appliance 
what is the maximum number of 12-gaugeTHHN conductors that can be inst...
NICET Soils Level 1 Already Verified Answers 
Define C117 
The determination of the amount of material finer than a 75-um (No.200) sieve 
What is the significance of C136? -To determine the grading of materials, -compliance of particle size distribution, -provide data for control of producti...
Preview 2 out of 7 pages
Add to cartNICET Soils Level 1 Already Verified Answers 
Define C117 
The determination of the amount of material finer than a 75-um (No.200) sieve 
What is the significance of C136? -To determine the grading of materials, -compliance of particle size distribution, -provide data for control of producti...
NICET Level 1 ITM of Water Based Systems Rated A+ 
What is a purpose of a control valve 
Control Flow to water based fire protection system 
The gauge on the quick opening device shall indicate _____ as compared to the gauge on the system 
side of the dry pipe valve? 
the same pressure 
What t...
Preview 3 out of 16 pages
Add to cartNICET Level 1 ITM of Water Based Systems Rated A+ 
What is a purpose of a control valve 
Control Flow to water based fire protection system 
The gauge on the quick opening device shall indicate _____ as compared to the gauge on the system 
side of the dry pipe valve? 
the same pressure 
What t...
NICET - LEVEL 1 – SPRINKLER VERIFIED ANSWERS 
30' 
48" 
92dBa 
Maximum length of single ladder section 
An extention ladder is required to have overlap between sections of 
At what dB is hearing protection required (based on exposure time)? 
Elevate their feet 
How do you treat s...
Preview 1 out of 1 pages
Add to cartNICET - LEVEL 1 – SPRINKLER VERIFIED ANSWERS 
30' 
48" 
92dBa 
Maximum length of single ladder section 
An extention ladder is required to have overlap between sections of 
At what dB is hearing protection required (based on exposure time)? 
Elevate their feet 
How do you treat s...
Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.
You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.
Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.
Stuvia is a marketplace, so you are not buying this document from us, but from seller CertifiedGrades. Stuvia facilitates payment to the seller.
No, you only buy these notes for $30.39. You're not tied to anything after your purchase.
4.6 stars on Google & Trustpilot (+1000 reviews)
80202 documents were sold in the last 30 days
Founded in 2010, the go-to place to buy study notes for 14 years now