[Show more]Journeyman Electrician Exam 1 - Q & A When a pull box contains conductors of size 4 AWG and larger and a straight pull of the conductors is to be made, the length of the box shall NOT be less than _____ times the trade diameter of the largest conduit entering the box. a) six b) four c) eight d) tw...
Preview 2 out of 6 pages
Add to cartJourneyman Electrician Exam 1 - Q & A When a pull box contains conductors of size 4 AWG and larger and a straight pull of the conductors is to be made, the length of the box shall NOT be less than _____ times the trade diameter of the largest conduit entering the box. a) six b) four c) eight d) tw...
Journeyman Electrician Exam 2 - Q & A In indoor areas where walls are frequently washed, such as laundries or car washes, metal conduit and metal panelboards shall be mounted with a _____ space between the wall and conduit or panelboard when the equipment is installed exposed. a) 3/4 inch b) 1/2 i...
Preview 2 out of 6 pages
Add to cartJourneyman Electrician Exam 2 - Q & A In indoor areas where walls are frequently washed, such as laundries or car washes, metal conduit and metal panelboards shall be mounted with a _____ space between the wall and conduit or panelboard when the equipment is installed exposed. a) 3/4 inch b) 1/2 i...
Journeyman Electrician Exam 3 - Q & A The NEC requires the MAXIMUM length permitted for a flexible cord supplying a 208-volt, single-phase, room air-conditioner to be _____. a) 4 feet b) 6 feet c) 8 feet d) 10 feet Ref: 440.64 In general, which of the following receptacle outlets in a commercial k...
Preview 2 out of 6 pages
Add to cartJourneyman Electrician Exam 3 - Q & A The NEC requires the MAXIMUM length permitted for a flexible cord supplying a 208-volt, single-phase, room air-conditioner to be _____. a) 4 feet b) 6 feet c) 8 feet d) 10 feet Ref: 440.64 In general, which of the following receptacle outlets in a commercial k...
Journeyman Electrician Exam 4 - Q & A When grounding the structural reinforcing steel of a swimming pool, what is the smallest size grounding conductor permitted for this installation? a) 12 AWG b) 10 AWG c) 8 AWG d) 6 AWG Ref: 680.26(B)(1)(a) and (b) A surge-protective device (SPD) is a protectiv...
Preview 2 out of 6 pages
Add to cartJourneyman Electrician Exam 4 - Q & A When grounding the structural reinforcing steel of a swimming pool, what is the smallest size grounding conductor permitted for this installation? a) 12 AWG b) 10 AWG c) 8 AWG d) 6 AWG Ref: 680.26(B)(1)(a) and (b) A surge-protective device (SPD) is a protectiv...
Journeyman Electrician Exam 5 - Q & A When armored cable (AC) is installed in thermal insulation, the ampacity of the cable shall be that of _____ conductors. a) 60°C b) 75°C c) 194°F d) 90°C Ref: 320.80(A) Receptacle outlets installed on a branch-circuit rated at 30 amperes are permitted to h...
Preview 2 out of 7 pages
Add to cartJourneyman Electrician Exam 5 - Q & A When armored cable (AC) is installed in thermal insulation, the ampacity of the cable shall be that of _____ conductors. a) 60°C b) 75°C c) 194°F d) 90°C Ref: 320.80(A) Receptacle outlets installed on a branch-circuit rated at 30 amperes are permitted to h...
Journeyman Electrician Final Exam - Q & A Which one of the following listed raceways is NOT permitted for use of enclosing control wiring for electric motor-driven fire pumps? a) flexible metal conduit (FMC) b) liquidtight flexible metal conduit (LFMC) c) liquidtight flexible nonmetallic conduit (...
Preview 2 out of 8 pages
Add to cartJourneyman Electrician Final Exam - Q & A Which one of the following listed raceways is NOT permitted for use of enclosing control wiring for electric motor-driven fire pumps? a) flexible metal conduit (FMC) b) liquidtight flexible metal conduit (LFMC) c) liquidtight flexible nonmetallic conduit (...
Journeyman Electrician Practice Test - Questions, Answers and Rationales For dwelling units, GFCI protection is required for all single-phase, 125-volt, 15- and 20-ampere receptacles installed within six (6) feet of the top inside edge of the bowl of sinks located in _____. a. laundry rooms b. bat...
Preview 2 out of 10 pages
Add to cartJourneyman Electrician Practice Test - Questions, Answers and Rationales For dwelling units, GFCI protection is required for all single-phase, 125-volt, 15- and 20-ampere receptacles installed within six (6) feet of the top inside edge of the bowl of sinks located in _____. a. laundry rooms b. bat...
Journeyman Electrician Test - Q & A In dwelling units, all 125-volt, single-phase, 15- or 20-ampere receptacle outlets installed within six (6) feet of the outside edge of a sink in a laundry room shall be provided with _____. both GFCI protection and AFCI protection A 30 hp, 480-volt, 3-phase wou...
Preview 2 out of 10 pages
Add to cartJourneyman Electrician Test - Q & A In dwelling units, all 125-volt, single-phase, 15- or 20-ampere receptacle outlets installed within six (6) feet of the outside edge of a sink in a laundry room shall be provided with _____. both GFCI protection and AFCI protection A 30 hp, 480-volt, 3-phase wou...
Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.
You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.
Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.
Stuvia is a marketplace, so you are not buying this document from us, but from seller NurseHenny. Stuvia facilitates payment to the seller.
No, you only buy these notes for $31.49. You're not tied to anything after your purchase.
4.6 stars on Google & Trustpilot (+1000 reviews)
81989 documents were sold in the last 30 days
Founded in 2010, the go-to place to buy study notes for 14 years now