[Show more]How long does an owner have to fix a significant violation that does not pose an imminent threat to 
human health and safety or environment before being issued a red tag? 
a) 24 hours 
b) 48 hours 
c) 7 days 
d) 30 days - c) 7 days; CCR 2717.1(b) 
Which one of the following can perform ELD? 
a) lice...
Preview 2 out of 9 pages
Add to cartHow long does an owner have to fix a significant violation that does not pose an imminent threat to 
human health and safety or environment before being issued a red tag? 
a) 24 hours 
b) 48 hours 
c) 7 days 
d) 30 days - c) 7 days; CCR 2717.1(b) 
Which one of the following can perform ELD? 
a) lice...
Type A Fire Extinguisher - Puts out paper, wood, cloth, rubbish fires. 
Type B Fire Extinguisher - Puts out flammable and combustible liquids. 
Type C Fire Extinguisher - Puts out electrical fires. 
According to CCR, Title 23 UST Regulations, what is the frequency that the monitor system certificati...
Preview 2 out of 10 pages
Add to cartType A Fire Extinguisher - Puts out paper, wood, cloth, rubbish fires. 
Type B Fire Extinguisher - Puts out flammable and combustible liquids. 
Type C Fire Extinguisher - Puts out electrical fires. 
According to CCR, Title 23 UST Regulations, what is the frequency that the monitor system certificati...
Corrosion Specialist - designs and certifies cathodic protection system 
Secondary containment shall be constructed to contain at least the following volumes: - A. 100% of 
usable capacity of primary where there is only one primary is within the secondary 
B. 150% of the largest container if there a...
Preview 1 out of 4 pages
Add to cartCorrosion Specialist - designs and certifies cathodic protection system 
Secondary containment shall be constructed to contain at least the following volumes: - A. 100% of 
usable capacity of primary where there is only one primary is within the secondary 
B. 150% of the largest container if there a...
Is this statement true or false? Fiberglass and flexible plastic piping do not need to have cathodic 
protection. - False. 
Cathodic protection - a technique used to control the corrosion of a metal surface by making it the 
cathode of an electrochemical cell. A simple method of protection connects ...
Preview 2 out of 10 pages
Add to cartIs this statement true or false? Fiberglass and flexible plastic piping do not need to have cathodic 
protection. - False. 
Cathodic protection - a technique used to control the corrosion of a metal surface by making it the 
cathode of an electrochemical cell. A simple method of protection connects ...
1. One of the significant causes of leaks in underground liquid storage systems is ____________ 
________________ - Improper Installation 
2. Written Plans are required to - obtain permits, solicit bids, and provide precise guidance for 
installers. 
3. The plans should - Describe the property, iden...
Preview 3 out of 21 pages
Add to cart1. One of the significant causes of leaks in underground liquid storage systems is ____________ 
________________ - Improper Installation 
2. Written Plans are required to - obtain permits, solicit bids, and provide precise guidance for 
installers. 
3. The plans should - Describe the property, iden...
What is the hold time for soil and preserved GW GRO samples? - 14 days 
Is an ICC certification needed to install an AST? - No 
Flammability limits of gasoline - 1.4 to 7.6% 
How many days do you have from a tank closure to report/provide the UST checklist to ECY? - 30 
days 
MTCA Method A lead CUL,...
Preview 2 out of 7 pages
Add to cartWhat is the hold time for soil and preserved GW GRO samples? - 14 days 
Is an ICC certification needed to install an AST? - No 
Flammability limits of gasoline - 1.4 to 7.6% 
How many days do you have from a tank closure to report/provide the UST checklist to ECY? - 30 
days 
MTCA Method A lead CUL,...
Secondary containment required for all new USTs (date) - January 1, 1984 
(25291; H&SC) 
23 CCR closure requirements do not apply to UST closed prior to ____________________ (date) - 
January 1, 1984 
(2670(I); CCR) 
New UST with pressured piping must have secondary containment after _______________...
Preview 2 out of 8 pages
Add to cartSecondary containment required for all new USTs (date) - January 1, 1984 
(25291; H&SC) 
23 CCR closure requirements do not apply to UST closed prior to ____________________ (date) - 
January 1, 1984 
(2670(I); CCR) 
New UST with pressured piping must have secondary containment after _______________...
Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.
You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.
Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.
Stuvia is a marketplace, so you are not buying this document from us, but from seller VasilyKichigin. Stuvia facilitates payment to the seller.
No, you only buy these notes for $35.99. You're not tied to anything after your purchase.
4.6 stars on Google & Trustpilot (+1000 reviews)
82871 documents were sold in the last 30 days
Founded in 2010, the go-to place to buy study notes for 14 years now