[Show more]B - correct answer A third 90-degree bend may be permitted in a conduit run if the run does NOT exceed ______? 
 
A 5 m (16.5') 
B 10 m (33') 
C 15 m (50') 
D 30 m (100') 
 
C - correct answer Which of the following is a property of an electromagnetic field built around a conductor that oppo...
Preview 4 out of 42 pages
Add to cartB - correct answer A third 90-degree bend may be permitted in a conduit run if the run does NOT exceed ______? 
 
A 5 m (16.5') 
B 10 m (33') 
C 15 m (50') 
D 30 m (100') 
 
C - correct answer Which of the following is a property of an electromagnetic field built around a conductor that oppo...
The function of which type of cable is to provide interconnections between equipment rooms and telecommunications rooms? - correct answer Backbone cable 
 
The main components of backbone cabling are cabling pathways, cables, miscellaneous support facilities and which of the following? - correct ...
Preview 1 out of 4 pages
Add to cartThe function of which type of cable is to provide interconnections between equipment rooms and telecommunications rooms? - correct answer Backbone cable 
 
The main components of backbone cabling are cabling pathways, cables, miscellaneous support facilities and which of the following? - correct ...
Three transmission methods are - correct answer Symplex, half duplex, full duplex 
 
The choice of a specific transport medium is influenced by 5 economics and technical considerations such as the: - correct answer Physical construction, type of services, topology and size of the network, transm...
Preview 3 out of 18 pages
Add to cartThree transmission methods are - correct answer Symplex, half duplex, full duplex 
 
The choice of a specific transport medium is influenced by 5 economics and technical considerations such as the: - correct answer Physical construction, type of services, topology and size of the network, transm...
Figure 12.1-Pic on test-Transposed pairs - correct answer 2 pairs wrong on 1 end (12-2) 
 
Propagation delay = - correct answer A measurement of the time for signal to travel from one end of the transmission path to the other (12-4) 
 
TDR troubleshooting = - correct answer Copper return loss ...
Preview 1 out of 2 pages
Add to cartFigure 12.1-Pic on test-Transposed pairs - correct answer 2 pairs wrong on 1 end (12-2) 
 
Propagation delay = - correct answer A measurement of the time for signal to travel from one end of the transmission path to the other (12-4) 
 
TDR troubleshooting = - correct answer Copper return loss ...
design and implementation/installation - correct answer Telecommunications project management (TPM) typically consists of two distinct processes: 
 
Design PM Tasks - correct answer Review expression of interest for client 
Perform a user needs analysis 
Perform site surveys and meet with clie...
Preview 4 out of 41 pages
Add to cartdesign and implementation/installation - correct answer Telecommunications project management (TPM) typically consists of two distinct processes: 
 
Design PM Tasks - correct answer Review expression of interest for client 
Perform a user needs analysis 
Perform site surveys and meet with clie...
Pathway Considerations - correct answer In planning for OSP cabling, cable infrastructure must be determined irst. The choices are underground, direct-buried, and aerial. 
 
Underground plant - correct answer most expensive system, has the highest cable placement capacity, longest projected life...
Preview 1 out of 3 pages
Add to cartPathway Considerations - correct answer In planning for OSP cabling, cable infrastructure must be determined irst. The choices are underground, direct-buried, and aerial. 
 
Underground plant - correct answer most expensive system, has the highest cable placement capacity, longest projected life...
The 2 main considerations concerning the existing cabling are? - correct answer Grandfathered system 
Abandoned cable 11-25 
 
The type of cutover where cross-connects are relocated one pair after another until completed is called a - correct answer rolling cut 11-28 
 
Which practice involves m...
Preview 2 out of 11 pages
Add to cartThe 2 main considerations concerning the existing cabling are? - correct answer Grandfathered system 
Abandoned cable 11-25 
 
The type of cutover where cross-connects are relocated one pair after another until completed is called a - correct answer rolling cut 11-28 
 
Which practice involves m...
What is the Best practice in the case of a wetland that you cannot feasibly avoid? - correct answer Directional Bore under the wetland 
 
What is necessary for a permit to cross a navigable waterway? - correct answer Environmental Management Plan 
 
What condition requires special permitting pro...
Preview 1 out of 3 pages
Add to cartWhat is the Best practice in the case of a wetland that you cannot feasibly avoid? - correct answer Directional Bore under the wetland 
 
What is necessary for a permit to cross a navigable waterway? - correct answer Environmental Management Plan 
 
What condition requires special permitting pro...
If lead to height ratio is between 1/2 and 3/4 and only 2 or 3 spans the head guy should be_____ than suspension strand. - correct answer One SIze Larger 
 
Important set of deliverables - correct answer Design documents 
 
OSP cost variance - correct answer 10% 
 
CSI 27 
CSI 28 
CSI 31 
CSI ...
Preview 2 out of 12 pages
Add to cartIf lead to height ratio is between 1/2 and 3/4 and only 2 or 3 spans the head guy should be_____ than suspension strand. - correct answer One SIze Larger 
 
Important set of deliverables - correct answer Design documents 
 
OSP cost variance - correct answer 10% 
 
CSI 27 
CSI 28 
CSI 31 
CSI ...
body language - correct answer 55% 
 
Tone of voice - correct answer 38% 
 
Choice of words - correct answer 7% 
 
Pair Twists... what is the length of twist ranges of balanced twisted pair cabling - correct answer Range is from 6mm(.24in) to 150mm(6in) 
 
Max supportable distance for twiste...
Preview 2 out of 5 pages
Add to cartbody language - correct answer 55% 
 
Tone of voice - correct answer 38% 
 
Choice of words - correct answer 7% 
 
Pair Twists... what is the length of twist ranges of balanced twisted pair cabling - correct answer Range is from 6mm(.24in) to 150mm(6in) 
 
Max supportable distance for twiste...
What is inductace? - correct answer 1) The property of an electrical force field built around a conductor when current flows through it. 2) The resistance to change in current. 
 
What is impedance? - correct answer The total opposition (resistance and reactance [capacitance and inductance]) tha...
Preview 2 out of 8 pages
Add to cartWhat is inductace? - correct answer 1) The property of an electrical force field built around a conductor when current flows through it. 2) The resistance to change in current. 
 
What is impedance? - correct answer The total opposition (resistance and reactance [capacitance and inductance]) tha...
Total dispersion is the______ modal dispersion and chromatic dispersion. - correct answer Sum of 
 
Bend insensitive optical fiber adds a third layer of glass between the core and the cladding of the fiber. - correct answer True 
 
Ohm's Law - correct answer V = I x R or I = V / R or R = V / ...
Preview 1 out of 3 pages
Add to cartTotal dispersion is the______ modal dispersion and chromatic dispersion. - correct answer Sum of 
 
Bend insensitive optical fiber adds a third layer of glass between the core and the cladding of the fiber. - correct answer True 
 
Ohm's Law - correct answer V = I x R or I = V / R or R = V / ...
Balanced twisted-pair cables have a nominal characteristic impedance of - correct answer 100 ohms at 100 MHz 
 
Insulation - correct answer Copper wires must be physically separated 
 
UTP - correct answer unshielded twisted-pair 
 
screened/shielded cabling offers - correct answer a higher ...
Preview 2 out of 10 pages
Add to cartBalanced twisted-pair cables have a nominal characteristic impedance of - correct answer 100 ohms at 100 MHz 
 
Insulation - correct answer Copper wires must be physically separated 
 
UTP - correct answer unshielded twisted-pair 
 
screened/shielded cabling offers - correct answer a higher ...
Choose Correct Term: 
1. Attenuation, 2. Bandwidth, 3. Cable Loss, 4. Cladding, 5. Connector, 6. Dispersion, 7. Ferrule (Optical Fiber), 8. FC, 9. Furcating Harness, 10. Insertion Loss, 11. LC Connector/Adapter, 12. Multimode Optical Fiber, 13. SFF, 14. SC 
 
Definition: 
The decrease in magnitude o...
Preview 4 out of 62 pages
Add to cartChoose Correct Term: 
1. Attenuation, 2. Bandwidth, 3. Cable Loss, 4. Cladding, 5. Connector, 6. Dispersion, 7. Ferrule (Optical Fiber), 8. FC, 9. Furcating Harness, 10. Insertion Loss, 11. LC Connector/Adapter, 12. Multimode Optical Fiber, 13. SFF, 14. SC 
 
Definition: 
The decrease in magnitude o...
BICSI Installer 2 copper exam 2023 with 100% correct answers
Preview 2 out of 11 pages
Add to cartBICSI Installer 2 copper exam 2023 with 100% correct answers
BICSI Installer 2 exam 2023 with 100% correct answers
Preview 2 out of 6 pages
Add to cartBICSI Installer 2 exam 2023 with 100% correct answers
Code - correct answer Addresses the safety of persons, property and the environment associated with the ITS cabling Installation 
 
NEC - correct answer National electric code 
 
Frequency conversion chart - correct answer One thousand hertz = 1KHz 
 
One million Kilohertz = 1 MHz 
 
One billi...
Preview 2 out of 11 pages
Add to cartCode - correct answer Addresses the safety of persons, property and the environment associated with the ITS cabling Installation 
 
NEC - correct answer National electric code 
 
Frequency conversion chart - correct answer One thousand hertz = 1KHz 
 
One million Kilohertz = 1 MHz 
 
One billi...
25-pair color code - correct answer White - Blue, orange, green, brown, slate 
Red - Blue, orange, green, brown, slate 
Black - Blue, orange, green, brown, slate 
Yellow - Blue, orange, green, brown, slate 
Violet - Blue, orange, green, brown, slate 
 
Fiber color code - correct answer Blue, Orang...
Preview 3 out of 17 pages
Add to cart25-pair color code - correct answer White - Blue, orange, green, brown, slate 
Red - Blue, orange, green, brown, slate 
Black - Blue, orange, green, brown, slate 
Yellow - Blue, orange, green, brown, slate 
Violet - Blue, orange, green, brown, slate 
 
Fiber color code - correct answer Blue, Orang...
SAFETY REVIEW 
OSHA - correct answer Occupational Safety and Health Administration 
 
What is the 1st step you should take to safely assist an injured person during an emergency? - correct answer Survey the Scene 
 
When Surveying a Victim what does the B in ABC stand For? - correct answer Bre...
Preview 2 out of 11 pages
Add to cartSAFETY REVIEW 
OSHA - correct answer Occupational Safety and Health Administration 
 
What is the 1st step you should take to safely assist an injured person during an emergency? - correct answer Survey the Scene 
 
When Surveying a Victim what does the B in ABC stand For? - correct answer Bre...
Attenuation - correct answer The Decrease in magnitude or power loss of a signal. 
 
Decibels, dB - correct answer Unit of measurement for attenuation. 
 
American Wire Gauge (AWG) - correct answer The numerical system for designating wire diameter. 
 
inverse relationship - correct answer A...
Preview 4 out of 33 pages
Add to cartAttenuation - correct answer The Decrease in magnitude or power loss of a signal. 
 
Decibels, dB - correct answer Unit of measurement for attenuation. 
 
American Wire Gauge (AWG) - correct answer The numerical system for designating wire diameter. 
 
inverse relationship - correct answer A...
Cross Connects, Backbone Cabling, and Administration - correct answer Administration systems include requirements for; identifiers - that serve to locate the element record and administration scheme such as the standards found in ANSI/TIA 606-B, records - which can be paper based, spreadsheets, da...
Preview 4 out of 35 pages
Add to cartCross Connects, Backbone Cabling, and Administration - correct answer Administration systems include requirements for; identifiers - that serve to locate the element record and administration scheme such as the standards found in ANSI/TIA 606-B, records - which can be paper based, spreadsheets, da...
T or F: A STANDARD can be described as "a rule or set of rules intended to ensure safety during the installation and use of materials, components, fixtures, systems, premises, and related objects. - correct answer False (describes Codes) 
 
A ______ is an authoritative rule that controls or gover...
Preview 1 out of 4 pages
Add to cartT or F: A STANDARD can be described as "a rule or set of rules intended to ensure safety during the installation and use of materials, components, fixtures, systems, premises, and related objects. - correct answer False (describes Codes) 
 
A ______ is an authoritative rule that controls or gover...
1 Trillionth (10 ' 12) cycles - correct answer 1 picohertz (pHz) 
 
1 Billionth (10'9) cycles - correct answer 1 nanohertz (nHz) 
 
1 millionth (10'6) cycles - correct answer 1 microhertz 
 
1 thousand (10'6) cycles - correct answer 1 milliheartz 
 
1 cycle - correct answer 1 HZ 
 
V%R - co...
Preview 2 out of 12 pages
Add to cart1 Trillionth (10 ' 12) cycles - correct answer 1 picohertz (pHz) 
 
1 Billionth (10'9) cycles - correct answer 1 nanohertz (nHz) 
 
1 millionth (10'6) cycles - correct answer 1 microhertz 
 
1 thousand (10'6) cycles - correct answer 1 milliheartz 
 
1 cycle - correct answer 1 HZ 
 
V%R - co...
high pair count cable can be loaded onto reels that are up too - correct answer 2 meters (6.5 FT high) and 1.5meters (5 FT wide) 
 
elements common to all cabling installation projects - correct answer knowledge of industry standards and codes 
understanding the project design and compliance wit...
Preview 1 out of 4 pages
Add to carthigh pair count cable can be loaded onto reels that are up too - correct answer 2 meters (6.5 FT high) and 1.5meters (5 FT wide) 
 
elements common to all cabling installation projects - correct answer knowledge of industry standards and codes 
understanding the project design and compliance wit...
In the absence of a specified distance, what is the minimum space front and back for work area? - correct answer Minimum of, 3.3 feet front and back workspace. 
 
If an ER layout is not provided where can details be found by laying out an equipment room. - correct answer Laying out an ER can be fo...
Preview 1 out of 4 pages
Add to cartIn the absence of a specified distance, what is the minimum space front and back for work area? - correct answer Minimum of, 3.3 feet front and back workspace. 
 
If an ER layout is not provided where can details be found by laying out an equipment room. - correct answer Laying out an ER can be fo...
ICT - correct answer Information and communications technology 
 
Transmission - correct answer Movement of information by electromagnetic energy in the form of electrical or optical signals from one point to another through a transport medium 
 
Transport medium - correct answer Air, balance ...
Preview 2 out of 6 pages
Add to cartICT - correct answer Information and communications technology 
 
Transmission - correct answer Movement of information by electromagnetic energy in the form of electrical or optical signals from one point to another through a transport medium 
 
Transport medium - correct answer Air, balance ...
Codes address the safety of persons, property and the environment associated with the ITS cabling installation. - correct answer TRUE 
 
The IEEE standard associated with Ethernet (or LANs) is 802.3 - correct answer TRUE 
 
"TIA" stands for Telecommunications Industry Association. - correct a...
Preview 3 out of 24 pages
Add to cartCodes address the safety of persons, property and the environment associated with the ITS cabling installation. - correct answer TRUE 
 
The IEEE standard associated with Ethernet (or LANs) is 802.3 - correct answer TRUE 
 
"TIA" stands for Telecommunications Industry Association. - correct a...
Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.
You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.
Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.
Stuvia is a marketplace, so you are not buying this document from us, but from seller JUICYGRADES. Stuvia facilitates payment to the seller.
No, you only buy these notes for $40.49. You're not tied to anything after your purchase.
4.6 stars on Google & Trustpilot (+1000 reviews)
67096 documents were sold in the last 30 days
Founded in 2010, the go-to place to buy study notes for 14 years now