Package deal
BICSI BUNDLED exams 2023 with 100% correct answers
BICSI exam 2023 with 100% correct answers BICSI IN225 7.0, Installer 2 exam 2023 with 100% correct answers
[Show more]BICSI exam 2023 with 100% correct answers BICSI IN225 7.0, Installer 2 exam 2023 with 100% correct answers
[Show more]B - correct answer A third 90-degree bend may be permitted in a conduit run if the run does NOT exceed ______? 
 
A 5 m (16.5') 
B 10 m (33') 
C 15 m (50') 
D 30 m (100') 
 
C - correct answer Which of the following is a property of an electromagnetic field built around a conductor that oppo...
Preview 4 out of 42 pages
Add to cartB - correct answer A third 90-degree bend may be permitted in a conduit run if the run does NOT exceed ______? 
 
A 5 m (16.5') 
B 10 m (33') 
C 15 m (50') 
D 30 m (100') 
 
C - correct answer Which of the following is a property of an electromagnetic field built around a conductor that oppo...
The function of which type of cable is to provide interconnections between equipment rooms and telecommunications rooms? - correct answer Backbone cable 
 
The main components of backbone cabling are cabling pathways, cables, miscellaneous support facilities and which of the following? - correct ...
Preview 1 out of 4 pages
Add to cartThe function of which type of cable is to provide interconnections between equipment rooms and telecommunications rooms? - correct answer Backbone cable 
 
The main components of backbone cabling are cabling pathways, cables, miscellaneous support facilities and which of the following? - correct ...
Three transmission methods are - correct answer Symplex, half duplex, full duplex 
 
The choice of a specific transport medium is influenced by 5 economics and technical considerations such as the: - correct answer Physical construction, type of services, topology and size of the network, transm...
Preview 3 out of 18 pages
Add to cartThree transmission methods are - correct answer Symplex, half duplex, full duplex 
 
The choice of a specific transport medium is influenced by 5 economics and technical considerations such as the: - correct answer Physical construction, type of services, topology and size of the network, transm...
Figure 12.1-Pic on test-Transposed pairs - correct answer 2 pairs wrong on 1 end (12-2) 
 
Propagation delay = - correct answer A measurement of the time for signal to travel from one end of the transmission path to the other (12-4) 
 
TDR troubleshooting = - correct answer Copper return loss ...
Preview 1 out of 2 pages
Add to cartFigure 12.1-Pic on test-Transposed pairs - correct answer 2 pairs wrong on 1 end (12-2) 
 
Propagation delay = - correct answer A measurement of the time for signal to travel from one end of the transmission path to the other (12-4) 
 
TDR troubleshooting = - correct answer Copper return loss ...
design and implementation/installation - correct answer Telecommunications project management (TPM) typically consists of two distinct processes: 
 
Design PM Tasks - correct answer Review expression of interest for client 
Perform a user needs analysis 
Perform site surveys and meet with clie...
Preview 4 out of 41 pages
Add to cartdesign and implementation/installation - correct answer Telecommunications project management (TPM) typically consists of two distinct processes: 
 
Design PM Tasks - correct answer Review expression of interest for client 
Perform a user needs analysis 
Perform site surveys and meet with clie...
Pathway Considerations - correct answer In planning for OSP cabling, cable infrastructure must be determined irst. The choices are underground, direct-buried, and aerial. 
 
Underground plant - correct answer most expensive system, has the highest cable placement capacity, longest projected life...
Preview 1 out of 3 pages
Add to cartPathway Considerations - correct answer In planning for OSP cabling, cable infrastructure must be determined irst. The choices are underground, direct-buried, and aerial. 
 
Underground plant - correct answer most expensive system, has the highest cable placement capacity, longest projected life...
1x sold
The 2 main considerations concerning the existing cabling are? - correct answer Grandfathered system 
Abandoned cable 11-25 
 
The type of cutover where cross-connects are relocated one pair after another until completed is called a - correct answer rolling cut 11-28 
 
Which practice involves m...
Preview 2 out of 11 pages
Add to cartThe 2 main considerations concerning the existing cabling are? - correct answer Grandfathered system 
Abandoned cable 11-25 
 
The type of cutover where cross-connects are relocated one pair after another until completed is called a - correct answer rolling cut 11-28 
 
Which practice involves m...
What is the Best practice in the case of a wetland that you cannot feasibly avoid? - correct answer Directional Bore under the wetland 
 
What is necessary for a permit to cross a navigable waterway? - correct answer Environmental Management Plan 
 
What condition requires special permitting pro...
Preview 1 out of 3 pages
Add to cartWhat is the Best practice in the case of a wetland that you cannot feasibly avoid? - correct answer Directional Bore under the wetland 
 
What is necessary for a permit to cross a navigable waterway? - correct answer Environmental Management Plan 
 
What condition requires special permitting pro...
1x sold
If lead to height ratio is between 1/2 and 3/4 and only 2 or 3 spans the head guy should be_____ than suspension strand. - correct answer One SIze Larger 
 
Important set of deliverables - correct answer Design documents 
 
OSP cost variance - correct answer 10% 
 
CSI 27 
CSI 28 
CSI 31 
CSI ...
Preview 2 out of 12 pages
Add to cartIf lead to height ratio is between 1/2 and 3/4 and only 2 or 3 spans the head guy should be_____ than suspension strand. - correct answer One SIze Larger 
 
Important set of deliverables - correct answer Design documents 
 
OSP cost variance - correct answer 10% 
 
CSI 27 
CSI 28 
CSI 31 
CSI ...
body language - correct answer 55% 
 
Tone of voice - correct answer 38% 
 
Choice of words - correct answer 7% 
 
Pair Twists... what is the length of twist ranges of balanced twisted pair cabling - correct answer Range is from 6mm(.24in) to 150mm(6in) 
 
Max supportable distance for twiste...
Preview 2 out of 5 pages
Add to cartbody language - correct answer 55% 
 
Tone of voice - correct answer 38% 
 
Choice of words - correct answer 7% 
 
Pair Twists... what is the length of twist ranges of balanced twisted pair cabling - correct answer Range is from 6mm(.24in) to 150mm(6in) 
 
Max supportable distance for twiste...
What is inductace? - correct answer 1) The property of an electrical force field built around a conductor when current flows through it. 2) The resistance to change in current. 
 
What is impedance? - correct answer The total opposition (resistance and reactance [capacitance and inductance]) tha...
Preview 2 out of 8 pages
Add to cartWhat is inductace? - correct answer 1) The property of an electrical force field built around a conductor when current flows through it. 2) The resistance to change in current. 
 
What is impedance? - correct answer The total opposition (resistance and reactance [capacitance and inductance]) tha...
Total dispersion is the______ modal dispersion and chromatic dispersion. - correct answer Sum of 
 
Bend insensitive optical fiber adds a third layer of glass between the core and the cladding of the fiber. - correct answer True 
 
Ohm's Law - correct answer V = I x R or I = V / R or R = V / ...
Preview 1 out of 3 pages
Add to cartTotal dispersion is the______ modal dispersion and chromatic dispersion. - correct answer Sum of 
 
Bend insensitive optical fiber adds a third layer of glass between the core and the cladding of the fiber. - correct answer True 
 
Ohm's Law - correct answer V = I x R or I = V / R or R = V / ...
Balanced twisted-pair cables have a nominal characteristic impedance of - correct answer 100 ohms at 100 MHz 
 
Insulation - correct answer Copper wires must be physically separated 
 
UTP - correct answer unshielded twisted-pair 
 
screened/shielded cabling offers - correct answer a higher ...
Preview 2 out of 10 pages
Add to cartBalanced twisted-pair cables have a nominal characteristic impedance of - correct answer 100 ohms at 100 MHz 
 
Insulation - correct answer Copper wires must be physically separated 
 
UTP - correct answer unshielded twisted-pair 
 
screened/shielded cabling offers - correct answer a higher ...
Choose Correct Term: 
1. Attenuation, 2. Bandwidth, 3. Cable Loss, 4. Cladding, 5. Connector, 6. Dispersion, 7. Ferrule (Optical Fiber), 8. FC, 9. Furcating Harness, 10. Insertion Loss, 11. LC Connector/Adapter, 12. Multimode Optical Fiber, 13. SFF, 14. SC 
 
Definition: 
The decrease in magnitude o...
Preview 4 out of 62 pages
Add to cartChoose Correct Term: 
1. Attenuation, 2. Bandwidth, 3. Cable Loss, 4. Cladding, 5. Connector, 6. Dispersion, 7. Ferrule (Optical Fiber), 8. FC, 9. Furcating Harness, 10. Insertion Loss, 11. LC Connector/Adapter, 12. Multimode Optical Fiber, 13. SFF, 14. SC 
 
Definition: 
The decrease in magnitude o...
BICSI Installer 2 copper exam 2023 with 100% correct answers
Preview 2 out of 11 pages
Add to cartBICSI Installer 2 copper exam 2023 with 100% correct answers
BICSI Installer 2 exam 2023 with 100% correct answers
Preview 2 out of 6 pages
Add to cartBICSI Installer 2 exam 2023 with 100% correct answers
Code - correct answer Addresses the safety of persons, property and the environment associated with the ITS cabling Installation 
 
NEC - correct answer National electric code 
 
Frequency conversion chart - correct answer One thousand hertz = 1KHz 
 
One million Kilohertz = 1 MHz 
 
One billi...
Preview 2 out of 11 pages
Add to cartCode - correct answer Addresses the safety of persons, property and the environment associated with the ITS cabling Installation 
 
NEC - correct answer National electric code 
 
Frequency conversion chart - correct answer One thousand hertz = 1KHz 
 
One million Kilohertz = 1 MHz 
 
One billi...
25-pair color code - correct answer White - Blue, orange, green, brown, slate 
Red - Blue, orange, green, brown, slate 
Black - Blue, orange, green, brown, slate 
Yellow - Blue, orange, green, brown, slate 
Violet - Blue, orange, green, brown, slate 
 
Fiber color code - correct answer Blue, Orang...
Preview 3 out of 17 pages
Add to cart25-pair color code - correct answer White - Blue, orange, green, brown, slate 
Red - Blue, orange, green, brown, slate 
Black - Blue, orange, green, brown, slate 
Yellow - Blue, orange, green, brown, slate 
Violet - Blue, orange, green, brown, slate 
 
Fiber color code - correct answer Blue, Orang...
SAFETY REVIEW 
OSHA - correct answer Occupational Safety and Health Administration 
 
What is the 1st step you should take to safely assist an injured person during an emergency? - correct answer Survey the Scene 
 
When Surveying a Victim what does the B in ABC stand For? - correct answer Bre...
Preview 2 out of 11 pages
Add to cartSAFETY REVIEW 
OSHA - correct answer Occupational Safety and Health Administration 
 
What is the 1st step you should take to safely assist an injured person during an emergency? - correct answer Survey the Scene 
 
When Surveying a Victim what does the B in ABC stand For? - correct answer Bre...
Attenuation - correct answer The Decrease in magnitude or power loss of a signal. 
 
Decibels, dB - correct answer Unit of measurement for attenuation. 
 
American Wire Gauge (AWG) - correct answer The numerical system for designating wire diameter. 
 
inverse relationship - correct answer A...
Preview 4 out of 33 pages
Add to cartAttenuation - correct answer The Decrease in magnitude or power loss of a signal. 
 
Decibels, dB - correct answer Unit of measurement for attenuation. 
 
American Wire Gauge (AWG) - correct answer The numerical system for designating wire diameter. 
 
inverse relationship - correct answer A...
Cross Connects, Backbone Cabling, and Administration - correct answer Administration systems include requirements for; identifiers - that serve to locate the element record and administration scheme such as the standards found in ANSI/TIA 606-B, records - which can be paper based, spreadsheets, da...
Preview 4 out of 35 pages
Add to cartCross Connects, Backbone Cabling, and Administration - correct answer Administration systems include requirements for; identifiers - that serve to locate the element record and administration scheme such as the standards found in ANSI/TIA 606-B, records - which can be paper based, spreadsheets, da...
T or F: A STANDARD can be described as "a rule or set of rules intended to ensure safety during the installation and use of materials, components, fixtures, systems, premises, and related objects. - correct answer False (describes Codes) 
 
A ______ is an authoritative rule that controls or gover...
Preview 1 out of 4 pages
Add to cartT or F: A STANDARD can be described as "a rule or set of rules intended to ensure safety during the installation and use of materials, components, fixtures, systems, premises, and related objects. - correct answer False (describes Codes) 
 
A ______ is an authoritative rule that controls or gover...
1 Trillionth (10 ' 12) cycles - correct answer 1 picohertz (pHz) 
 
1 Billionth (10'9) cycles - correct answer 1 nanohertz (nHz) 
 
1 millionth (10'6) cycles - correct answer 1 microhertz 
 
1 thousand (10'6) cycles - correct answer 1 milliheartz 
 
1 cycle - correct answer 1 HZ 
 
V%R - co...
Preview 2 out of 12 pages
Add to cart1 Trillionth (10 ' 12) cycles - correct answer 1 picohertz (pHz) 
 
1 Billionth (10'9) cycles - correct answer 1 nanohertz (nHz) 
 
1 millionth (10'6) cycles - correct answer 1 microhertz 
 
1 thousand (10'6) cycles - correct answer 1 milliheartz 
 
1 cycle - correct answer 1 HZ 
 
V%R - co...
In the absence of a specified distance, what is the minimum space front and back for work area? - correct answer Minimum of, 3.3 feet front and back workspace. 
 
If an ER layout is not provided where can details be found by laying out an equipment room. - correct answer Laying out an ER can be fo...
Preview 0 out of 0 pages
Add to cartIn the absence of a specified distance, what is the minimum space front and back for work area? - correct answer Minimum of, 3.3 feet front and back workspace. 
 
If an ER layout is not provided where can details be found by laying out an equipment room. - correct answer Laying out an ER can be fo...
Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.
You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.
Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.
Stuvia is a marketplace, so you are not buying this document from us, but from seller YANCHY. Stuvia facilitates payment to the seller.
No, you only buy these notes for $40.49. You're not tied to anything after your purchase.
4.6 stars on Google & Trustpilot (+1000 reviews)
67096 documents were sold in the last 30 days
Founded in 2010, the go-to place to buy study notes for 14 years now