[Show more]The operable part of a manually actuated alarm initiating device shall be not less than ____ inches AFF. <<Ans>> 42 inches 
 
Consider the use of grounding electrodes. Rod and pipe electrodes shall not be less than____ feet in length? <<Ans>> 8 feet 
 
Smoke detectors s...
Preview 2 out of 10 pages
Add to cartThe operable part of a manually actuated alarm initiating device shall be not less than ____ inches AFF. <<Ans>> 42 inches 
 
Consider the use of grounding electrodes. Rod and pipe electrodes shall not be less than____ feet in length? <<Ans>> 8 feet 
 
Smoke detectors s...
When testing a water level supervisory switch serving a pressure tank a signal shall indicate if the water level _____________from the required level 
 
(NFPA 72, Table 14.4.3.2 17 (j) (4) <<Ans>> rises or falls over 3 inches 
 
If combination audible/visible appliances are installed ...
Preview 2 out of 12 pages
Add to cartWhen testing a water level supervisory switch serving a pressure tank a signal shall indicate if the water level _____________from the required level 
 
(NFPA 72, Table 14.4.3.2 17 (j) (4) <<Ans>> rises or falls over 3 inches 
 
If combination audible/visible appliances are installed ...
What is a purpose of a control valve <<Ans>> Control Flow to water based fire protection system 
 
The gauge on the quick opening device shall indicate _____ as compared to the gauge on the system side of the dry pipe valve? <<Ans>> the same pressure 
 
What type of test ...
Preview 1 out of 4 pages
Add to cartWhat is a purpose of a control valve <<Ans>> Control Flow to water based fire protection system 
 
The gauge on the quick opening device shall indicate _____ as compared to the gauge on the system side of the dry pipe valve? <<Ans>> the same pressure 
 
What type of test ...
When a device is inaccessible due to excessive height, such as an atrium, what it the maximum interval for testing? <<Ans>> 18 months 
 
When installing a wall-mounted fire telephone appliance to the public, what is the acceptable maximum mounting height from the floor? <<Ans>...
Preview 2 out of 7 pages
Add to cartWhen a device is inaccessible due to excessive height, such as an atrium, what it the maximum interval for testing? <<Ans>> 18 months 
 
When installing a wall-mounted fire telephone appliance to the public, what is the acceptable maximum mounting height from the floor? <<Ans>...
Secondary power for remote supervising station systems shall be capable of normal operation for ___ hours and then operate the system in alarm for ___ minutes? <<Ans>> 24 / 5 
 
A fire alarm system which serves contiguous or noncontiguous properties under one ownership is considered? ...
Preview 2 out of 5 pages
Add to cartSecondary power for remote supervising station systems shall be capable of normal operation for ___ hours and then operate the system in alarm for ___ minutes? <<Ans>> 24 / 5 
 
A fire alarm system which serves contiguous or noncontiguous properties under one ownership is considered? ...
Toggle hangers shall be permitted only for the support of pipe __________ inches or smaller in size under ceilings of hollow tile or metal lath and plaster. <<Ans>> 1 2/2 in. (ref. NFPA 13 2016 Sec. 9.2.1.1.2. 
 
While conducting a flow test, the chosen hydrant should be ______ <&l...
Preview 2 out of 11 pages
Add to cartToggle hangers shall be permitted only for the support of pipe __________ inches or smaller in size under ceilings of hollow tile or metal lath and plaster. <<Ans>> 1 2/2 in. (ref. NFPA 13 2016 Sec. 9.2.1.1.2. 
 
While conducting a flow test, the chosen hydrant should be ______ <&l...
If combination audible/ visible appliances are installed, the location of the installed appliance shall be determined by the requirements of the _____. <<Ans>> the visible appliance. 
 
The maximum number of 12- gauge THHN wires that can be installed in 1-inch EMT. <<Ans>>...
Preview 2 out of 5 pages
Add to cartIf combination audible/ visible appliances are installed, the location of the installed appliance shall be determined by the requirements of the _____. <<Ans>> the visible appliance. 
 
The maximum number of 12- gauge THHN wires that can be installed in 1-inch EMT. <<Ans>>...
Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.
You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.
Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.
Stuvia is a marketplace, so you are not buying this document from us, but from seller Mawseron. Stuvia facilitates payment to the seller.
No, you only buy these notes for $12.49. You're not tied to anything after your purchase.
4.6 stars on Google & Trustpilot (+1000 reviews)
80796 documents were sold in the last 30 days
Founded in 2010, the go-to place to buy study notes for 14 years now