[Show more]For other than one-and two-family dwellings, when building a new electrical service, at least one (1) 125- 
volt, single-phase, 15- or 20-ampere-rated receptacle outlet shall be located within at LEAST _____ of 
the electrical service equipment? - 50 feet 
The ampacity of a conductor is defined by t...
Preview 2 out of 11 pages
Add to cartFor other than one-and two-family dwellings, when building a new electrical service, at least one (1) 125- 
volt, single-phase, 15- or 20-ampere-rated receptacle outlet shall be located within at LEAST _____ of 
the electrical service equipment? - 50 feet 
The ampacity of a conductor is defined by t...
When determining the initial standard size time-delay fuse for branch-circuit, short-circuit, and groundfault protection for a threephase, continuous duty, squirrel cage, AC motor, the fuse shall have a rating of 
_____ of the FLC of the motor. When the value determined does not correspond to a stan...
Preview 2 out of 11 pages
Add to cartWhen determining the initial standard size time-delay fuse for branch-circuit, short-circuit, and groundfault protection for a threephase, continuous duty, squirrel cage, AC motor, the fuse shall have a rating of 
_____ of the FLC of the motor. When the value determined does not correspond to a stan...
A fitting is a part of a wiring system that is intended primarily to perform which type of function? - 
mechanical 
When the disconnecting means of a transformer is located remotely it must be? - lockable 
If installed and routed on the outside of a raceway, the length of the equipment bonding jumpe...
Preview 2 out of 10 pages
Add to cartA fitting is a part of a wiring system that is intended primarily to perform which type of function? - 
mechanical 
When the disconnecting means of a transformer is located remotely it must be? - lockable 
If installed and routed on the outside of a raceway, the length of the equipment bonding jumpe...
when an electrical circuit tested with ohm meter, a short circuit is indicated by a reading of... - 0 
If the panel board rating is 100 amperes, what shall be the overcurrent device rating located in 
panelboard? - NEC 408.36 
the overcurrent device rating must not be greater than panel board rating...
Preview 1 out of 2 pages
Add to cartwhen an electrical circuit tested with ohm meter, a short circuit is indicated by a reading of... - 0 
If the panel board rating is 100 amperes, what shall be the overcurrent device rating located in 
panelboard? - NEC 408.36 
the overcurrent device rating must not be greater than panel board rating...
A fixed light will be allowed to be 30 amp provided the socket is rated ____ duty. 
a. Light 
b. Medium 
c. Heavy 
d. Extra Heavy - c. Heavy 
From the Skilled Trades Act, Section 7 "Except as otherwise provided in this article or in subsection (3), 
and individual other than an individual who is li...
Preview 3 out of 18 pages
Add to cartA fixed light will be allowed to be 30 amp provided the socket is rated ____ duty. 
a. Light 
b. Medium 
c. Heavy 
d. Extra Heavy - c. Heavy 
From the Skilled Trades Act, Section 7 "Except as otherwise provided in this article or in subsection (3), 
and individual other than an individual who is li...
An electromagnet can be switched on and off - And advantage of an electromagnet over a 
permanent magnet is 
Scatters light uniformly in all directions - An excellent diffuser surface is one that 
In a photovoltaic cell - Light is converted into electricity 
Armature - The rotating part of a DC moto...
Preview 2 out of 6 pages
Add to cartAn electromagnet can be switched on and off - And advantage of an electromagnet over a 
permanent magnet is 
Scatters light uniformly in all directions - An excellent diffuser surface is one that 
In a photovoltaic cell - Light is converted into electricity 
Armature - The rotating part of a DC moto...
Conductors with _____ marked on the insulation are NOT approved for use in a wet location. - THHN 
conductors with THHN insulation are approved for use in dry and damp locations only and conductors 
with THWN, THHW, and THW insulation are recognized for use in dry and wet locations. 
Given: A one-fa...
Preview 2 out of 12 pages
Add to cartConductors with _____ marked on the insulation are NOT approved for use in a wet location. - THHN 
conductors with THHN insulation are approved for use in dry and damp locations only and conductors 
with THWN, THHW, and THW insulation are recognized for use in dry and wet locations. 
Given: A one-fa...
Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.
You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.
Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.
Stuvia is a marketplace, so you are not buying this document from us, but from seller PatrickKaylian. Stuvia facilitates payment to the seller.
No, you only buy these notes for $13.49. You're not tied to anything after your purchase.
4.6 stars on Google & Trustpilot (+1000 reviews)
75323 documents were sold in the last 30 days
Founded in 2010, the go-to place to buy study notes for 14 years now