NICET BUNDLED exams 2023 with 100% correct answers
NICET Level 1 Fire Alarm Systems exam 2023 with 100% correct answersNICET Level 1 exam 2023 with 100% correct answers
[Show more]NICET Level 1 Fire Alarm Systems exam 2023 with 100% correct answersNICET Level 1 exam 2023 with 100% correct answers
[Show more]4 wires 
what is the maximum number of 14 AWG RHH conductors which can be installed in 1/2 rigid metal conduit? 
 
 
 
3.5'-48" to the actuator 
Which of the following would be an appropriate mounting height for a pull station? 
 
 
 
1 flash per second 
What is the minimum flash rate for a visibl...
Preview 2 out of 8 pages
Add to cart4 wires 
what is the maximum number of 14 AWG RHH conductors which can be installed in 1/2 rigid metal conduit? 
 
 
 
3.5'-48" to the actuator 
Which of the following would be an appropriate mounting height for a pull station? 
 
 
 
1 flash per second 
What is the minimum flash rate for a visibl...
When testing a water level supervisory switch serving a pressure tank a signal shall indicate if the water level _____________from the required level 
 
(NFPA 72, Table 14.4.3.2 17 (j) (4) 
rises or falls over 3 inches 
 
 
 
If combination audible/visible appliances are installed the location of th...
Preview 3 out of 17 pages
Add to cartWhen testing a water level supervisory switch serving a pressure tank a signal shall indicate if the water level _____________from the required level 
 
(NFPA 72, Table 14.4.3.2 17 (j) (4) 
rises or falls over 3 inches 
 
 
 
If combination audible/visible appliances are installed the location of th...
When a device is inaccessible due to excessive height, such as an atrium, what it the maximum interval for testing? 
18 months 
 
 
 
When installing a wall-mounted fire telephone appliance to the public, what is the acceptable maximum mounting height from the floor? 
66 inches 
 
 
 
Elevator lobby...
Preview 2 out of 10 pages
Add to cartWhen a device is inaccessible due to excessive height, such as an atrium, what it the maximum interval for testing? 
18 months 
 
 
 
When installing a wall-mounted fire telephone appliance to the public, what is the acceptable maximum mounting height from the floor? 
66 inches 
 
 
 
Elevator lobby...
Fire Alarm Code? 
NFPA 72 
 
 
 
National Electric Code? 
NFPA 70 
 
 
 
AHJ? 
Authority Having Jurisdiction 
 
 
 
Disconnecting means for fire alarm power shall be what color? 
Red 
 
 
 
If a combination audible visible appliance is installed, the location of the installed appliance shall be dete...
Preview 2 out of 10 pages
Add to cartFire Alarm Code? 
NFPA 72 
 
 
 
National Electric Code? 
NFPA 70 
 
 
 
AHJ? 
Authority Having Jurisdiction 
 
 
 
Disconnecting means for fire alarm power shall be what color? 
Red 
 
 
 
If a combination audible visible appliance is installed, the location of the installed appliance shall be dete...
The operable part of a manually actuated alarm initiating device shall be not less than ____ inches AFF? 
42 
 
 
 
Consider the use of grounding electrodes. Rod and pipe electrodes shall not be less than____ feet in length? 
8 
 
 
 
Smoke detectors should not be located in a direct airflow or clos...
Preview 2 out of 6 pages
Add to cartThe operable part of a manually actuated alarm initiating device shall be not less than ____ inches AFF? 
42 
 
 
 
Consider the use of grounding electrodes. Rod and pipe electrodes shall not be less than____ feet in length? 
8 
 
 
 
Smoke detectors should not be located in a direct airflow or clos...
if a combination audible/visible appliances are installed, the location of the installed appliance shall be determined by the requirements of 
the visible appliance 
 
 
 
what is the maximum number of 12-gaugeTHHN conductors that can be installed in 1-inch EMT 
26 
 
 
 
Do you resistors are connec...
Preview 1 out of 3 pages
Add to cartif a combination audible/visible appliances are installed, the location of the installed appliance shall be determined by the requirements of 
the visible appliance 
 
 
 
what is the maximum number of 12-gaugeTHHN conductors that can be installed in 1-inch EMT 
26 
 
 
 
Do you resistors are connec...
Whats the maximum coverage area of any fire sprinkler? 
225sqft 
 
 
 
NFPA 14 
Standard for the Installation of Standpipe and Hose Systems 
 
 
 
NFPA 15 
Standard for Water Spray Fixed Systems for Fire Protection 
 
 
 
When was OSHA founded and what does ti stand for? 
1971 - the occupational saf...
Preview 3 out of 28 pages
Add to cartWhats the maximum coverage area of any fire sprinkler? 
225sqft 
 
 
 
NFPA 14 
Standard for the Installation of Standpipe and Hose Systems 
 
 
 
NFPA 15 
Standard for Water Spray Fixed Systems for Fire Protection 
 
 
 
When was OSHA founded and what does ti stand for? 
1971 - the occupational saf...
What is a purpose of a control valve 
Control Flow to water based fire protection system 
 
 
 
The gauge on the quick opening device shall indicate _____ as compared to the gauge on the system side of the dry pipe valve? 
the same pressure 
 
 
 
What type of test shall be provided when a valve is ...
Preview 2 out of 5 pages
Add to cartWhat is a purpose of a control valve 
Control Flow to water based fire protection system 
 
 
 
The gauge on the quick opening device shall indicate _____ as compared to the gauge on the system side of the dry pipe valve? 
the same pressure 
 
 
 
What type of test shall be provided when a valve is ...
The maximum number of 14AWG wires that can be pulled straight through a 4" X 2 1/8" square trade size metal electrical box is? 
15 (NFPA 70 Table 314.16(A)) 
 
 
 
What is the first process or step you must take when working on a panel supplied with 120VAC? 
Lock out and Tag out the power source 
...
Preview 2 out of 6 pages
Add to cartThe maximum number of 14AWG wires that can be pulled straight through a 4" X 2 1/8" square trade size metal electrical box is? 
15 (NFPA 70 Table 314.16(A)) 
 
 
 
What is the first process or step you must take when working on a panel supplied with 120VAC? 
Lock out and Tag out the power source 
...
When using a pulse load tester on a sealed lead acid battery, the minimum acceptable capacity is... 
80% 
 
 
 
When a software change is made to a fire alarm system, what percentage of the initiating devices not affected by the change must be tested 
10% 
 
 
 
When testing elevator recall, the ele...
Preview 2 out of 7 pages
Add to cartWhen using a pulse load tester on a sealed lead acid battery, the minimum acceptable capacity is... 
80% 
 
 
 
When a software change is made to a fire alarm system, what percentage of the initiating devices not affected by the change must be tested 
10% 
 
 
 
When testing elevator recall, the ele...
Toggle hangers shall be permitted only for the support of pipe __________ inches or smaller in size under ceilings of hollow tile or metal lath and plaster. 
1 2/2 in. (ref. NFPA 13 2016 Sec. 9.2.1.1.2. 
 
 
 
While conducting a flow test, the chosen hydrant should be ______ 
As close to the propert...
Preview 3 out of 16 pages
Add to cartToggle hangers shall be permitted only for the support of pipe __________ inches or smaller in size under ceilings of hollow tile or metal lath and plaster. 
1 2/2 in. (ref. NFPA 13 2016 Sec. 9.2.1.1.2. 
 
 
 
While conducting a flow test, the chosen hydrant should be ______ 
As close to the propert...
Acceptance 
The written acceptance by the Department of the Work. 
 
 
 
acceptance testing 
Testing conducted by the Department to measure the degree of compliance to the Contract 
 
 
 
actual cost 
The computed cost using calculations provided 
 
 
 
addendum 
A Contract revision or response to a...
Preview 2 out of 8 pages
Add to cartAcceptance 
The written acceptance by the Department of the Work. 
 
 
 
acceptance testing 
Testing conducted by the Department to measure the degree of compliance to the Contract 
 
 
 
actual cost 
The computed cost using calculations provided 
 
 
 
addendum 
A Contract revision or response to a...
Define C117 
The determination of the amount of material finer than a 75-um (No.200) sieve 
 
 
 
What is the significance of C136? 
-To determine the grading of materials, 
-compliance of particle size distribution, 
-provide data for control of production of various aggregate 
-developing relation...
Preview 2 out of 8 pages
Add to cartDefine C117 
The determination of the amount of material finer than a 75-um (No.200) sieve 
 
 
 
What is the significance of C136? 
-To determine the grading of materials, 
-compliance of particle size distribution, 
-provide data for control of production of various aggregate 
-developing relation...
Who is responsible for the inspection, testing, maintenance and impairment of a water based fire protection system? 
The Property owner or designated representative 
 
 
 
Who's responsibility is it to provide accessibility to components of a water based fire protection system? 
The property owner ...
Preview 2 out of 10 pages
Add to cartWho is responsible for the inspection, testing, maintenance and impairment of a water based fire protection system? 
The Property owner or designated representative 
 
 
 
Who's responsibility is it to provide accessibility to components of a water based fire protection system? 
The property owner ...
25NFPA Chapter One 
set out the administration or scope of NFPA 25 
 
 
 
Where can the referenced publication that are used to create NFPA 25 be found? 
Chapter 2 
 
 
 
What is the defination of AHJ 
An orgsnization, office or individual responsible for enforcing the requirements of a code or stan...
Preview 2 out of 6 pages
Add to cart25NFPA Chapter One 
set out the administration or scope of NFPA 25 
 
 
 
Where can the referenced publication that are used to create NFPA 25 be found? 
Chapter 2 
 
 
 
What is the defination of AHJ 
An orgsnization, office or individual responsible for enforcing the requirements of a code or stan...
The operable part of a manually actuated alarm initiating device shall be not less than ____ inches AFF. 
42 inches 
 
 
 
Consider the use of grounding electrodes. Rod and pipe electrodes shall not be less than____ feet in length? 
8 feet 
 
 
 
Smoke detectors should not be located in a direct air...
Preview 2 out of 12 pages
Add to cartThe operable part of a manually actuated alarm initiating device shall be not less than ____ inches AFF. 
42 inches 
 
 
 
Consider the use of grounding electrodes. Rod and pipe electrodes shall not be less than____ feet in length? 
8 feet 
 
 
 
Smoke detectors should not be located in a direct air...
What is Bulk Density used for? (c29) 
Determining Mass/volume relationship for conversions in purchase agreements 
 
 
 
What is the dimensions of plate glass? (C29) 
1/4" thick and at least 1" larger than the diameter of the measure 
 
 
 
What are the requirements for a thermometer? (C1064) 
has...
Preview 2 out of 7 pages
Add to cartWhat is Bulk Density used for? (c29) 
Determining Mass/volume relationship for conversions in purchase agreements 
 
 
 
What is the dimensions of plate glass? (C29) 
1/4" thick and at least 1" larger than the diameter of the measure 
 
 
 
What are the requirements for a thermometer? (C1064) 
has...
Secondary power for remote supervising station systems shall be capable of normal operation for ___ hours and then operate the system in alarm for ___ minutes? 
24 / 5 
 
 
 
A fire alarm system which serves contiguous or noncontiguous properties under one ownership is considered? 
Proprietary syste...
Preview 2 out of 6 pages
Add to cartSecondary power for remote supervising station systems shall be capable of normal operation for ___ hours and then operate the system in alarm for ___ minutes? 
24 / 5 
 
 
 
A fire alarm system which serves contiguous or noncontiguous properties under one ownership is considered? 
Proprietary syste...
Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.
You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.
Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.
Stuvia is a marketplace, so you are not buying this document from us, but from seller YANCHY. Stuvia facilitates payment to the seller.
No, you only buy these notes for $50.49. You're not tied to anything after your purchase.
4.6 stars on Google & Trustpilot (+1000 reviews)
80796 documents were sold in the last 30 days
Founded in 2010, the go-to place to buy study notes for 14 years now