Package deal
Journeyman Tests Bundle
Journeyman Tests Bundle
[Show more]Journeyman Tests Bundle
[Show more]For other than one-and two-family dwellings, when building a new electrical service, at least one (1) 125-volt, single-phase, 15- or 20-ampere-rated receptacle outlet shall be located within at LEAST _____ of the electrical service equipment? - Answer 50 feet 
 
The ampacity of a conductor is defi...
Preview 2 out of 14 pages
Add to cartFor other than one-and two-family dwellings, when building a new electrical service, at least one (1) 125-volt, single-phase, 15- or 20-ampere-rated receptacle outlet shall be located within at LEAST _____ of the electrical service equipment? - Answer 50 feet 
 
The ampacity of a conductor is defi...
Conductors with _____ marked on the insulation are NOT approved for use in a wet location. - Answer THHN 
 
conductors with THHN insulation are approved for use in dry and damp locations only and conductors with THWN, THHW, and THW insulation are recognized for use in dry and wet locations. 
 
Giv...
Preview 2 out of 15 pages
Add to cartConductors with _____ marked on the insulation are NOT approved for use in a wet location. - Answer THHN 
 
conductors with THHN insulation are approved for use in dry and damp locations only and conductors with THWN, THHW, and THW insulation are recognized for use in dry and wet locations. 
 
Giv...
A fixed light will be allowed to be 30 amp provided the socket is rated ____ duty. 
a. Light 
b. Medium 
c. Heavy 
d. Extra Heavy - Answer c. Heavy 
 
From the Skilled Trades Act, Section 7 "Except as otherwise provided in this article or in subsection (3), and individual other than an individual...
Preview 3 out of 23 pages
Add to cartA fixed light will be allowed to be 30 amp provided the socket is rated ____ duty. 
a. Light 
b. Medium 
c. Heavy 
d. Extra Heavy - Answer c. Heavy 
 
From the Skilled Trades Act, Section 7 "Except as otherwise provided in this article or in subsection (3), and individual other than an individual...
An electromagnet can be switched on and off - Answer And advantage of an electromagnet over a permanent magnet is 
 
Scatters light uniformly in all directions - Answer An excellent diffuser surface is one that 
 
In a photovoltaic cell - Answer Light is converted into electricity 
 
Armature ...
Preview 2 out of 8 pages
Add to cartAn electromagnet can be switched on and off - Answer And advantage of an electromagnet over a permanent magnet is 
 
Scatters light uniformly in all directions - Answer An excellent diffuser surface is one that 
 
In a photovoltaic cell - Answer Light is converted into electricity 
 
Armature ...
1/4" - Answer Threads of drainage fittings shall be tapped as to allow _____ pitch per foot 
 
4 lbs - Answer Lead used for safe pans shall not be less than ________ per square foot 
 
Copper Tube, Cast Iron, Stainless steel, ABS, PVC DWV - Answer Name 3 allowable materials for the DWV system...
Preview 3 out of 30 pages
Add to cart1/4" - Answer Threads of drainage fittings shall be tapped as to allow _____ pitch per foot 
 
4 lbs - Answer Lead used for safe pans shall not be less than ________ per square foot 
 
Copper Tube, Cast Iron, Stainless steel, ABS, PVC DWV - Answer Name 3 allowable materials for the DWV system...
Unless listed and identified otherwise, terminations and conductors of sizes 14 AWG through 1 AWG shall be rated at _____. 
 
a) 75°C 
b) 75°F 
c) 90°C 
d) 60°C - Answer D: 60°C 
Ref: 110.14(C)(1)(a)(1) 
 
The MINIMUM size copper equipment bonding jumper on the supply side of a service consis...
Preview 2 out of 10 pages
Add to cartUnless listed and identified otherwise, terminations and conductors of sizes 14 AWG through 1 AWG shall be rated at _____. 
 
a) 75°C 
b) 75°F 
c) 90°C 
d) 60°C - Answer D: 60°C 
Ref: 110.14(C)(1)(a)(1) 
 
The MINIMUM size copper equipment bonding jumper on the supply side of a service consis...
For electrically operated in - sink waste disposers, what is the minimum and maximum length allowed for electrical cable? - Answer 18 inches- 36 inches. 
422.16 (B)(1)(2) 
 
Rigid metal conduit must be securely fastened within how many feet of junction box? - Answer 3 feet. 
344.30 (A) 
*See exc...
Preview 1 out of 3 pages
Add to cartFor electrically operated in - sink waste disposers, what is the minimum and maximum length allowed for electrical cable? - Answer 18 inches- 36 inches. 
422.16 (B)(1)(2) 
 
Rigid metal conduit must be securely fastened within how many feet of junction box? - Answer 3 feet. 
344.30 (A) 
*See exc...
Where a water pipe passes over an indoor motor control center, leak protection apparatus shall have a MINIMUM clearance of _____. 
 
a) 6 feet to the protection apparatus 
b) 6 feet to the water pipe 
c) 6 1⁄2 feet to the protection apparatus 
d) 6 1⁄2 feet to the water pipe - Answer A: 6 feet...
Preview 2 out of 10 pages
Add to cartWhere a water pipe passes over an indoor motor control center, leak protection apparatus shall have a MINIMUM clearance of _____. 
 
a) 6 feet to the protection apparatus 
b) 6 feet to the water pipe 
c) 6 1⁄2 feet to the protection apparatus 
d) 6 1⁄2 feet to the water pipe - Answer A: 6 feet...
Where the outer sheath of Type MI cable is made of steel _____________. 
 
A. it shall provide an adequate path to serve as an equipment grounding conductor 
 
B. a separate equipment grounding conductor shall be provided 
 
C. the grounding and grounded conductors shall be connected together 
 
D. ...
Preview 2 out of 12 pages
Add to cartWhere the outer sheath of Type MI cable is made of steel _____________. 
 
A. it shall provide an adequate path to serve as an equipment grounding conductor 
 
B. a separate equipment grounding conductor shall be provided 
 
C. the grounding and grounded conductors shall be connected together 
 
D. ...
A fitting is a part of a wiring system that is intended primarily to perform which type of function? - Answer mechanical 
 
When the disconnecting means of a transformer is located remotely it must be? - Answer lockable 
 
If installed and routed on the outside of a raceway, the length of the eq...
Preview 2 out of 12 pages
Add to cartA fitting is a part of a wiring system that is intended primarily to perform which type of function? - Answer mechanical 
 
When the disconnecting means of a transformer is located remotely it must be? - Answer lockable 
 
If installed and routed on the outside of a raceway, the length of the eq...
There are six conductors in a race way connected to 75° C rated circuit breaker. Each wire has a 70 amp load using THHM conductors. The minimum size conductors used our #_________AWG - Answer 4 
 
Thermal insulation shall not be installed within _________inches of recessed lighting fixtures - Ans...
Preview 2 out of 8 pages
Add to cartThere are six conductors in a race way connected to 75° C rated circuit breaker. Each wire has a 70 amp load using THHM conductors. The minimum size conductors used our #_________AWG - Answer 4 
 
Thermal insulation shall not be installed within _________inches of recessed lighting fixtures - Ans...
2x sold
Defects on gas piping or fittings shall be _____.(A) repaired(B) replaced or repaired and retested(C) repaired by a certified welder(D) ignored, as the operating pressure is much less than the air test. - Answer B. Fitting shall be replaced or repaired and retested. UMC Section 1316.4.3 
 
Every a...
Preview 2 out of 15 pages
Add to cartDefects on gas piping or fittings shall be _____.(A) repaired(B) replaced or repaired and retested(C) repaired by a certified welder(D) ignored, as the operating pressure is much less than the air test. - Answer B. Fitting shall be replaced or repaired and retested. UMC Section 1316.4.3 
 
Every a...
2x sold
What must you do if you notice code violations in a homeowners house? - Answer Notify them and recommend ways to address them 
 
What must be done when performing an annual tune-up on a heating system? - Answer A combustion efficiency test and a copy must be posted on site 
 
Whenever a furnac...
Preview 3 out of 23 pages
Add to cartWhat must you do if you notice code violations in a homeowners house? - Answer Notify them and recommend ways to address them 
 
What must be done when performing an annual tune-up on a heating system? - Answer A combustion efficiency test and a copy must be posted on site 
 
Whenever a furnac...
2x sold
Plumbing Code Regulation SBC-3 - Answer State of Rhode Island Plumbing Code is known as: 
 
4' 6" Below Grade - Answer Water Services Shall Be Installed Not Less Than: 
 
Insulated/Heated or Both - Answer Piping installed in exterior walls or areas subject to freezing must: 
 
36" Below Gra...
Preview 2 out of 15 pages
Add to cartPlumbing Code Regulation SBC-3 - Answer State of Rhode Island Plumbing Code is known as: 
 
4' 6" Below Grade - Answer Water Services Shall Be Installed Not Less Than: 
 
Insulated/Heated or Both - Answer Piping installed in exterior walls or areas subject to freezing must: 
 
36" Below Gra...
Stuvia customers have reviewed more than 700,000 summaries. This how you know that you are buying the best documents.
You can quickly pay through credit card or Stuvia-credit for the summaries. There is no membership needed.
Your fellow students write the study notes themselves, which is why the documents are always reliable and up-to-date. This ensures you quickly get to the core!
You get a PDF, available immediately after your purchase. The purchased document is accessible anytime, anywhere and indefinitely through your profile.
Our satisfaction guarantee ensures that you always find a study document that suits you well. You fill out a form, and our customer service team takes care of the rest.
Stuvia is a marketplace, so you are not buying this document from us, but from seller cracker. Stuvia facilitates payment to the seller.
No, you only buy these notes for $39.99. You're not tied to anything after your purchase.
4.6 stars on Google & Trustpilot (+1000 reviews)
67866 documents were sold in the last 30 days
Founded in 2010, the go-to place to buy study notes for 14 years now