Oil burner motor - Study guides, Class notes & Summaries
Looking for the best study guides, study notes and summaries about Oil burner motor? On this page you'll find 234 study documents about Oil burner motor.
All 234 results
Sort by
-
Boilermaker NCCR Test Questions And Answers
- Exam (elaborations) • 10 pages • 2024
-
- $10.99
- 1x sold
- + learn more
Boilermaker NCCR Test Questions And Answers 
Boilermaker NCCR Test 
 
 
 
 
 
1 ft 3-3/4 in + 2 ft 1-1/16 in +5 ft 10- 7/8 in = - ANS 9 ft 3-11/16 in 
 
A 1-inch plate is to be cut. Why should an acetylene gerulator on a cutting rig not be adjusted over 15 PSI? - ANS Acetylene is unstable above this pressure 
 
A big control valve is pulled who is responsible for the rigging? - ANS Crane operator and rigger 
 
A boiler maker must have all of the following wh...
-
Oil Burner License Exam 2023 Questions and Answers
- Exam (elaborations) • 18 pages • 2023
-
Available in package deal
-
- $12.49
- 4x sold
- + learn more
What is the first thing a tech should do when arriving at a no combustion call? - Answer- Ask how many times the customer reset the unit. 
 
What is the best long term solution for preventing a clogged nozzle? - Answer- -Remove any underground storage tanks. 
-Install a quality oil filter. 
-Cut the suction line 10" above the tank outlet to prevent sludge. 
 
Hot water and steam valves are interchangeable. - Answer- False 
 
When in the presence of a flame, a cad cell normally reads.. - Answe...
-
Oil Burner License Exam Questions and Answers, Latest Updated 2024/2025 (Verified Answers)
- Exam (elaborations) • 20 pages • 2024
- Available in package deal
-
- $14.49
- + learn more
Oil Burner License Exam Questions and Answers, Latest Updated 2024/2025 (Verified Answers) What is the best long term solution for preventing a clogged nozzle? - Answer- -Remove 
any underground storage tanks. 
-Install a quality oil filter. 
-Cut the suction line 10" above the tank outlet to prevent sludge. 
Hot water and steam valves are interchangeable. - Answer- False 
When in the presence of a flame, a cad cell normally reads.. - Answer- 300-1000 ohms 
If a pump is used to bring oil to a l...
-
HVACR UNIT 55 QUESTIONS AND ANSWERS ALREADY PASSED
- Exam (elaborations) • 24 pages • 2024
- Available in package deal
-
- $9.99
- + learn more
HVACR UNIT 55 QUESTIONS AND 
ANSWERS ALREADY PASSED 
 
A major difference between the operation of an oil furnace and a gas furnace is that: The oil 
must be atomized before ignition. 
 
An oil furnace heat exchanger is built: Like a drum. 
 
How are oil burner nozzles rated? Cone shape, spray angle, and GPH 
 
Modern residential oil furnaces sense the flames using: A cadmium sulfide cell. 
 
Sealed combustion oil furnaces use: High static oil burners. 
 
Select the functions that the primary co...
-
Oil burner's test questions 1-200 Questions With 100% Correct Answers.
- Exam (elaborations) • 19 pages • 2024
- Available in package deal
-
- $9.69
- + learn more
In an electric circuit for the wattage to remain the same if the voltage drops, the amperage must - 
Answer-Increase 
Atomizing type burners were designed to burn which type of fuel - Answer-Type 2 fuel oil 
Pour point problems with outside above ground fuel tanks can be partially relieved by - Answer-Reducing 
the pour point of No. 2 fuel oil by blending it with No. 1 fuel oil. 
A fuel oil storage tank cannot be installed - Answer-In the furnace room with 5' of heating unit. 
The primary purpo...
Make study stress less painful
-
Oil burner's test questions 1-200
- Exam (elaborations) • 14 pages • 2024
-
- $12.49
- + learn more
In an electric circuit for the wattage to remain the same if the voltage drops, the amperage must - Answer-Increase 
 
Atomizing type burners were designed to burn which type of fuel - Answer-Type 2 fuel oil 
 
Pour point problems with outside above ground fuel tanks can be partially relieved by - Answer-Reducing the pour point of No. 2 fuel oil by blending it with No. 1 fuel oil. 
 
A fuel oil storage tank cannot be installed - Answer-In the furnace room with 5' of heating unit. 
 
The primary...
-
Oil Burner License Exam Questions and Answers, Latest Updated 2024/2025 (Verified Answers)
- Exam (elaborations) • 20 pages • 2024
- Available in package deal
-
- $13.99
- + learn more
Oil Burner License Exam Questions and Answers, Latest Updated 2024/2025 (Verified Answers) What is the first thing a tech should do when arriving at a no combustion call? - AnswerAsk how many times the customer reset the unit. 
What is the best long term solution for preventing a clogged nozzle? - Answer- -Remove 
any underground storage tanks. 
-Install a quality oil filter. 
-Cut the suction line 10" above the tank outlet to prevent sludge. 
Hot water and steam valves are interchangeable. - A...
-
Oil Burner License Exam Questions and Answers, Latest Updated 2024/2025 (Verified Answers)
- Exam (elaborations) • 20 pages • 2024
-
Available in package deal
-
- $14.99
- + learn more
Oil Burner License Exam Questions and Answers, Latest Updated 2024/2025 (Verified Answers) What is the first thing a tech should do when arriving at a no combustion call? - AnswerAsk how many times the customer reset the unit. 
What is the best long term solution for preventing a clogged nozzle? - Answer- -Remove 
any underground storage tanks. 
-Install a quality oil filter. 
-Cut the suction line 10" above the tank outlet to prevent sludge. 
Hot water and steam valves are interchangeable. - A...
-
Oil Burners Questions and Answers Rated A+
- Exam (elaborations) • 15 pages • 2024
- Available in package deal
-
- $9.99
- + learn more
Oil Burners Questions and Answers 
 
Rated A+ 
 
According to NFPA31-2001, what is the minimum size of the vent pipe on an oil storage tank 
1 1/4 inch 
 
Nozzles are available with three different spray patterns: Solid, semi-hollow, hollow 
 
What type of motor is used on a residential high pressure oil burner Split phase 
 
The most common motor speeds used in amerian made burners are 1725 and 3250 rpm 
 
If an oil has a high viscosity It is a thicker oil 
 
A service technician performs a com...
-
Oil burner's test questions 1-200 2024 with 100% correct answers
- Exam (elaborations) • 19 pages • 2024
-
Available in package deal
-
- $16.99
- + learn more
In an electric circuit for the wattage to remain the same if the voltage drops, the amperage must correct answersIncrease 
 
Atomizing type burners were designed to burn which type of fuel correct answersType 2 fuel oil 
 
Pour point problems with outside above ground fuel tanks can be partially relieved by correct answersReducing the pour point of No. 2 fuel oil by blending it with No. 1 fuel oil. 
 
A fuel oil storage tank cannot be installed correct answersIn the furnace room with 5' of heat...
-
Gas and Electric Heat Unit 32 Oil Heat exam 2024 with 100% correct answers
- Exam (elaborations) • 21 pages • 2024
-
Available in package deal
-
- $16.99
- + learn more
heat-producing system, heat-distributing system correct answersIntroduction to Oil-Fired Forced-Warm-Air Furnaces 
 
Oil-fired forced-warm-air furnaces have two main systems: 
 
A ________________________, consisting of the oil burner, fuel supply components, combustion chamber, and heat exchangers 
A ______________________, consisting of the blower, and other related components 
 
powered, starts correct answersIntroduction to Oil-Fired Forced-Warm-Air Furnaces 
 
When thermostat calls for heat...
Study stress? For sellers on Stuvia, these are actually golden times. KA-CHING! Earn from your study resources too and start uploading now. Discover all about earning on Stuvia